An A level chemistry enthalpy practical measures the temperature change when a reaction occurs, then uses that change to calculate the enthalpy change of the reaction. You typically record the initial and final temperatures of a solution, work out the heat absorbed or released using q = mcΔT, and then divide by the number of moles of the limiting reactant. This page gives you the full method, the calculations, and the common pitfalls so you can get accurate results and top marks.
Formula
The core equation is:
q = m × c × ΔT
- q = heat energy absorbed or released (joules, J)
- m = mass of the solution (grams, g) – usually you assume the density of the solution is the same as water (1.00 g/mL), so for a 100 mL solution, m = 100 g
- c = specific heat capacity of the solution (J/g·°C) – for dilute aqueous solutions, you use the value for water, 4.18 J/g·°C
- ΔT = temperature change (°C) = final temperature – initial temperature
Then the enthalpy change per mole is:
ΔH = −q / n
where n is the number of moles of the limiting reactant. The negative sign is included because the enthalpy change of the reaction is defined from the perspective of the system: if the solution heats up (q positive), the reaction is exothermic, so ΔH is negative.
Worked Example
Using the default values from the calculator: 100 g of solution, c = 4.18 J/g·°C, ΔT = 6.5 °C, and n = 0.025 mol.
Step 1: Calculate q.
q = 100 g × 4.18 J/g·°C × 6.5 °C = 2717 J (to 4 significant figures, 2717 J)
Step 2: Convert to kJ.
2717 J ÷ 1000 = 2.717 kJ
Step 3: Divide by moles.
ΔH = −2.717 kJ / 0.025 mol = −108.7 kJ/mol
The calculator gives −108.7 kJ/mol (rounded to 1 decimal place). The negative sign tells you the reaction is exothermic.
Assumptions
- The specific heat capacity of the solution equals that of water (4.18 J/g·°C). This is valid for dilute solutions.
- The density of the solution is 1.00 g/mL, so mass = volume in mL.
- No heat is lost to the surroundings (the calorimeter is perfectly insulated). In practice, this is never true, so results are often lower than theoretical values.
- The reaction goes to completion and the limiting reactant is fully consumed.
- The thermometer and container do not absorb significant heat.
How the Practical Works
In a typical A level enthalpy practical, you mix two solutions in a polystyrene cup (a simple calorimeter). The cup is a good insulator, so it slows heat loss. You measure the initial temperature of one solution, add the second solution (which is at the same temperature), stir, and record the highest or lowest temperature reached.
For an exothermic reaction (like neutralisation), the temperature rises. For an endothermic reaction (like dissolving ammonium nitrate), the temperature falls. You plot temperature against time and extrapolate back to the moment of mixing to correct for heat loss – this is the “cooling curve” method.
Then you use the temperature change, the mass of the solution, and the specific heat capacity to find q, and divide by the moles of the limiting reactant to get ΔH in kJ/mol.
Choosing the Right Method
There are several variations of the enthalpy practical, and the method you choose depends on the reaction type:
- Neutralisation: mix an acid and a base. Use equal volumes (e.g., 25 mL each) and record the temperature rise. The limiting reactant is usually the one with fewer moles.
- Displacement: add a metal powder (e.g., zinc) to a copper sulfate solution. The metal is in excess, so the limiting reactant is the copper sulfate.
- Dissolution: dissolve a solid salt in water. The mass of the solution is the mass of water plus the mass of salt.
- Combustion: burn a fuel (e.g., methanol) in a spirit burner and heat a known mass of water. Here, the heat from the flame is transferred to the water, and you measure the mass of fuel burned to find moles.
For combustion, the heat transfer is very inefficient (a lot of heat escapes), so the experimental ΔH is often much lower than the theoretical value. For solution reactions, the cup method is more accurate but still loses heat.
Common Problems and How to Avoid Them
Students often get inaccurate results because of simple mistakes:
- Heat loss: Even with a polystyrene cup, heat escapes. Use a lid and stir quickly. Extrapolate the cooling curve to correct.
- Wrong mass: For a solution, the mass is the total mass of the mixed solution, not just the solvent. If you mix 25 mL of acid and 25 mL of base, the mass is approximately 50 g.
- Wrong specific heat capacity: Use 4.18 J/g·°C for water, but if the solution is concentrated, the value may differ slightly. The error is usually small.
- Not identifying the limiting reactant: You must know which reactant is used up. If you have 0.025 mol of acid and 0.050 mol of base, the acid is limiting.
- Sign errors: If the temperature rises, ΔT is positive, q is positive, but ΔH is negative. Many students forget the negative sign.
- Unit conversion: q is in joules, but ΔH is in kJ/mol. Divide by 1000.
Comparing Experimental and Theoretical Values
Your experimental ΔH will usually be less negative (for exothermic reactions) than the theoretical value from data books. This is because of heat loss and incomplete reaction. The percentage error is calculated as:
% error = |(theoretical − experimental) / theoretical| × 100%
For example, if the theoretical ΔH for neutralisation is −57.1 kJ/mol and you get −50.0 kJ/mol, the error is about 12%. This is typical for a school lab. To improve accuracy, you can use a more sophisticated calorimeter, but for A level purposes, the cup method is acceptable.
Safety and Best Practice
Always wear safety goggles and follow your lab method and the safety data sheet (SDS) for the chemicals you use. When handling acids and bases, be careful of splashes. When doing combustion experiments, keep flammable liquids away from open flames and use a heatproof mat. Never taste or touch chemicals. Dispose of waste as instructed by your teacher.
For accurate temperature measurement, use a thermometer with a resolution of 0.1 °C or better. Stir continuously but gently to ensure even mixing without splashing. Record temperatures at regular intervals (e.g., every 30 seconds) so you can plot a graph.
Frequently Asked Questions
Why do I need to plot a graph of temperature against time?
Plotting a graph allows you to correct for heat loss. The temperature rises quickly after mixing, then starts to fall as heat is lost to the surroundings. By extrapolating the cooling portion back to the time of mixing, you get the true maximum temperature change that would have occurred with no heat loss. This gives a more accurate ΔT.
What is the difference between ΔH and q?
q is the heat energy change of the solution (in joules), which you measure. ΔH is the enthalpy change per mole of reaction (in kJ/mol), which is q divided by the number of moles of the limiting reactant, with the sign reversed. ΔH is an intensive property – it doesn’t depend on how much you use.
Why is my experimental value for ΔH less than the data book value?
Heat is lost to the surroundings, the cup absorbs some heat, and the reaction may not go to completion. Also, the specific heat capacity of the solution may be slightly different from water. These factors make the measured temperature change smaller, so the calculated ΔH is less negative (for exothermic reactions).
Can I use this method for any reaction?
No. This method works best for reactions that are fast, complete, and occur in solution. For slow reactions or those that don’t go to completion, the temperature change may be too small or the heat loss too large. For combustion reactions, you use a different setup (spirit burner) and the accuracy is lower.
How do I find the moles of the limiting reactant?
Use the concentration and volume of the solution: moles = concentration (mol/L) × volume (L). For a solid, use mass divided by molar mass. Identify which reactant is in the smallest stoichiometric amount – that is the limiting reactant.
What should I do if the temperature doesn’t change much?
If the temperature change is less than about 1 °C, the error in measurement becomes significant. Use a more concentrated solution or a larger volume to increase the change. Alternatively, use a thermometer with a finer resolution. If the reaction is very weakly exo- or endothermic, consider a different method.
Related
Formula used
in m | Mass of solution | g | 100 | 0 in c | Specific heat capacity | J/g·°C | 4.18 | 0 in dt | Temperature change (Tf - Ti) | °C | 6.5 | -273.15 in n | Moles of limiting reactant | mol | 0.025 | 0 out q | Heat energy change | J | m * c * dt | 1 out dh | Enthalpy change per mole | kJ/mol | q / 1000 / n | 1
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Normality to g/L Converter & Formula29.220 g/L
- Normality to meq/mL Conversion Calculator1.0000 meq/mL
- Normality Test Q-Q Plot: How to Read It
- Normality Test Results: How to Analyze Them
- Normality Slay the Spire?
- Normality Test for Paired t Test: How to Check