The A260/A280 ratio is a spectrophotometric measure used to assess the purity of a nucleic acid sample, with a value of ~2.0 generally accepted as pure for RNA and ~1.8 for DNA. You measure the absorbance of your sample at 260 nm and 280 nm, divide the two readings, and interpret the result against these benchmarks to detect protein or other contaminant carryover.
Formula
The ratio is simply the absorbance at 260 nm divided by the absorbance at 280 nm:
Ratio = A260 / A280
Where:
- A260 is the absorbance (optical density) of the sample at 260 nm, the wavelength where nucleic acids absorb most strongly due to their aromatic base rings.
- A280 is the absorbance at 280 nm, the wavelength where aromatic amino acids (tryptophan, tyrosine, phenylalanine) absorb most strongly, making it a proxy for protein contamination.
Both values are unitless, read from a UV spectrophotometer or a microvolume instrument (e.g., NanoDrop-style devices). The ratio itself is also unitless.
Worked Example
Suppose you dilute your RNA sample and measure an absorbance of 1.000 at 260 nm and 0.500 at 280 nm.
Plug into the formula:
Ratio = 1.000 / 0.500 = 2.000
This is right at the accepted “pure RNA” value. If your instrument reports 2.00, your sample is considered free of significant protein contamination. If you measured 1.500, that would suggest protein carryover (or a pH issue, discussed below).
Assumptions
- The sample is measured in a neutral pH buffer (e.g., 10 mM Tris-Cl, pH 7.5).
- The spectrophotometer is blanked with the same buffer used to dilute the sample.
- The absorbance readings are within the linear range of the instrument (typically 0.1–1.5 for cuvette-based systems).
- The sample contains only RNA and potential contaminants; the ratio does not distinguish RNA from DNA.
Why 260 nm and 280 nm?
Nucleic acids absorb UV light maximally at 260 nm because the conjugated double bonds in the purine and pyrimidine bases absorb photons at that wavelength. Proteins, however, have a different absorption profile: the aromatic side chains of tryptophan and tyrosine absorb strongly at 280 nm. By comparing the two, you get a rough estimate of how much protein is left in your RNA preparation relative to the RNA itself.
For pure RNA, the ratio is about 2.0. For pure DNA, it is about 1.8. The difference arises because RNA’s uracil absorbs slightly less at 280 nm than DNA’s thymine, and RNA is often single-stranded, which alters the absorption spectrum slightly. In practice, a ratio between 1.9 and 2.1 is considered acceptable for RNA, while values below 1.8 indicate protein contamination.
Common Problems and Misconceptions
pH changes the ratio. A common mistake is measuring RNA in plain water or in a low-pH buffer. At acidic pH, the absorbance at 280 nm increases, which lowers the A260/A280 ratio. A sample that looks “contaminated” at pH 5 may read a perfect 2.0 at pH 7.5. Always dilute your RNA in a buffered solution with a pH between 7 and 8.5 for reliable readings.
Phenol and chaotropic salts. Guanidine salts and phenol, used in many RNA extraction kits, absorb near 260 nm and can inflate the ratio. A high A260/A280 (above 2.2) may indicate phenol carryover, not “super-pure” RNA. Check the A260/A230 ratio as well—a value below 1.8 suggests guanidine or phenol contamination.
RNA vs. DNA. The ratio does not tell you whether your sample is RNA or DNA. Both absorb at 260 nm. Use a different method (e.g., RNase-free DNase digestion followed by PCR, or a fluorescent dye specific to RNA) to confirm the identity.
Dilution errors. If you pipette inaccurately, the ratio changes because the two absorbance readings are taken from the same dilution, but if your blank is wrong, both readings shift. Always prepare a fresh blank and mix the sample thoroughly.
How to Choose the Right Purity Metric
For routine RNA quality assessment, the A260/A280 ratio is a quick first check, but it is not sufficient on its own. Use the following workflow:
- Measure A260/A280 and A260/A230. The latter should be >1.8 for clean RNA, ideally >2.0.
- Run a denaturing agarose gel or a microfluidic chip (e.g., Bioanalyzer) to check for degradation—look for clear 28S and 18S ribosomal RNA bands (or a high RNA Integrity Number, RIN).
- If you plan to do qRT-PCR, consider a DNase treatment and a no-reverse-transcriptase control to rule out genomic DNA contamination.
For highly sensitive applications (RNA-seq, microarrays), the A260/A280 ratio is a screening tool, not a guarantee of quality. Always combine it with an integrity check.
Comparison with Other Purity Measures
Besides the A260/A280 ratio, labs commonly use:
- A260/A230 ratio: Measures contamination by chaotropic salts, phenol, and carbohydrates. A value >1.8 is considered good.
- Fluorescent RNA quantitation: Dyes like RiboGreen bind specifically to RNA and are more accurate than absorbance for low concentrations or when contaminants absorb at 260 nm.
- Gel electrophoresis or capillary electrophoresis: Provide information on RNA integrity (RIN value), not just purity.
- Mass spectrometry or HPLC: Used for advanced quality control, but overkill for most labs.
The A260/A280 ratio is cheap, fast, and requires no additional reagents, which is why it remains the default first-line check.
Practical Tips for Accurate Readings
- Measure in a buffer with pH 7.5 (e.g., 10 mM Tris-Cl, pH 7.5). Avoid water—pH can drop due to dissolved CO2.
- Use the same buffer for the blank and for diluting the sample.
- For microvolume instruments, pipette a consistent volume (e.g., 1–2 µL) and ensure the pedestal is clean between samples.
- If the absorbance at 260 nm is above ~1.5, dilute the sample further—absorbance is not linear at very high values.
- Record both the ratio and the raw A260 value so you can calculate RNA concentration later (1 A260 unit ≈ 40 µg/mL for RNA).
Follow your lab method, the safety data sheet (SDS) and your supervisor for any extraction or handling steps.
Frequently Asked Questions
What does an A260/A280 ratio of 2.1 mean for RNA? It is slightly above the accepted pure value of 2.0. This can indicate phenol carryover or a slightly alkaline pH. Check the A260/A230 ratio and consider re-purifying if the A230 is low.
Why is my RNA A260/A280 ratio low (1.6–1.7)? The most common causes are protein contamination, acidic pH of the dilution buffer, or too much salt. Try re-diluting in a neutral Tris buffer and re-measuring. If it stays low, a phenol-chloroform extraction or column cleanup may be needed.
Can I use the A260/A280 ratio to quantify RNA? Yes, but only as an estimate. The standard conversion is 1 absorbance unit at 260 nm = 40 µg/mL of RNA. However, this assumes a clean sample and does not account for degradation. For precise quantification, use a fluorescent assay.
Does the A260/A280 ratio distinguish between RNA and DNA? No. Both absorb at 260 nm. The ratio only indicates purity relative to protein. To confirm you have RNA, treat with RNase (degrades RNA) or use a RNA-specific dye.
Is a higher A260/A280 ratio always better? Not necessarily. Values above 2.2 often indicate phenol or guanidine contamination, which absorb at 260 nm and inflate the ratio. Aim for 1.9–2.1 for RNA.
What is the difference between A260/A280 and A260/A230? A260/A280 measures protein contamination; A260/A230 measures salt, carbohydrate, and phenol contamination. Both are needed for a full purity assessment.
Related
Formula used
in a260 | Absorbance at 260 nm | - | 1.000 | 0 in a280 | Absorbance at 280 nm | - | 0.500 | 0 out ratio | A260/A280 ratio | - | a260 / a280 | 3
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- QPP Calculator Canada: How It Works & How to Use It
- PPP Calculator World Bank: How It Works & How to Use It2,000.00
- PPP Calculator: India vs USA Cost Comparison1,000.00 USD
- PPP Calculator USD to INR: How It Works2,335 INR
- PPP Calculator India vs UK: Real Cost Comparison103.63 GBP
- PPP Calculator India vs Dubai: Real Cost Comparison8,954.58 AED