molecalculator

Moles & Molar Mass

API Gravity Temperature Correction Calculator

Calculator No. 01-3958 · Updated · Formula and assumptions shown below

Estimated API gravity at 60°F 34.44 °API
Estimated specific gravity at 60°F
0.8527
= 141.5 ÷ (Estimated API gravity at 60°F + 131.5)
Observed API gravity
35 °API
Set in the form below
Sample temperature
20 °C
Set in the form below
You enter
Observed API gravity (°API), Sample temperature (°C)
You get
Estimated API gravity at 60°F (°API), Estimated specific gravity at 60°F
Rounding
2 dp · 4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

An API gravity temperature correction calculator converts a petroleum liquid’s observed API gravity at a measured temperature to its equivalent API gravity at the standard reference temperature, usually 60°F (15.56°C). Enter the observed API gravity and sample temperature; the result is an estimate, because an accurate correction depends on the applicable petroleum measurement standard, product category, and table or algorithm.

Formula

This calculator uses a simplified linear thermal-expansion approximation, not a substitute for an official petroleum measurement table. It first estimates specific gravity at the sample temperature, then applies a fixed volume-correction factor and converts the estimated reference specific gravity back to API gravity.

  • Observed specific gravity: SGT = 141.5 / (APIT + 131.5).
  • Approximate reference specific gravity: SG60 = SGT + 0.00064 × (T − 15.5555556).
  • Reference API gravity: API60 = 141.5 / SG60 − 131.5.

Here APIT is the observed API gravity in degrees API, T is sample temperature in °C, SGT is specific gravity at that temperature, and SG60 is the estimated specific gravity at 60°F. The conversion 60°F = 15.5555556°C is built into the expression. The factor 0.00064 per °C is a generic approximation, not a universal petroleum expansion coefficient; real coefficients vary with liquid type and measurement conditions. The output is therefore useful for illustration or a rough check, not custody transfer or regulatory reporting.

Worked Example

Using the defaults, the observed API gravity is 35°API at 20°C.

  1. Convert observed API gravity to specific gravity: SGT = 141.5 / (35 + 131.5) = 141.5 / 166.5 = 0.8498498.
  2. Estimate specific gravity at 60°F: SG60 = 0.8498498 + 0.00064 × (20 − 15.5555556) = 0.8498498 + 0.0028444 ≈ 0.8526942.
  3. Convert back to API gravity: API60 = 141.5 / 0.8526942 − 131.5 ≈ 34.44°API.

The calculator displays 34.44°API and an estimated reference specific gravity of 0.8527. The calculations use unrounded intermediate values; the displayed values are rounded to the specified decimal places.

Assumptions

  • The reference temperature is 60°F, represented as 15.5555556°C.
  • A constant specific-gravity change of 0.00064 per °C is used as a generic linear approximation.
  • The sample is a petroleum liquid for which a simple thermal correction is a reasonable illustration; product-specific behavior is not modeled.
  • API gravity and specific gravity are measured consistently, and the input temperature is in °C.

What API Gravity Measures

API gravity is a scale used to describe how heavy or light a petroleum liquid is relative to water. Its relationship to specific gravity is API = 141.5 / SG at 60°F − 131.5. A higher API value indicates a lower specific gravity and therefore a lighter liquid. Water is approximately 10°API under the reference convention. API gravity is not a temperature-independent property: liquid density changes as temperature changes, so a measured gravity needs a stated temperature.

The reference temperature matters because two measurements of the same liquid at different temperatures cannot be compared fairly without correction. Petroleum documents commonly use 60°F, while some settings use other reference temperatures. Always check the stated base temperature and the density or gravity convention in a report before comparing values.

How to Use the Calculator

  • Enter the measured API gravity, not a specific-gravity value. The calculator’s first input must be in degrees API.
  • Enter the temperature at which that gravity was observed, in °C. Convert a Fahrenheit reading using (°F − 32) × 5 / 9.
  • Read the first output as the estimated API gravity at 60°F. The second output is the corresponding estimated specific gravity at that reference temperature.

For example, if an instrument or source reports 68°F, convert it to 20°C before entering it. Do not enter 68 in the temperature field: treating Fahrenheit as Celsius would produce a substantial error. If the source already reports gravity corrected to 60°F, do not correct it a second time.

Accuracy, Standards, and Common Errors

In commercial petroleum measurement, temperature correction is typically made using recognized petroleum measurement procedures and product-specific tables or algorithms, such as the relevant API MPMS or ASTM method. The precise method depends on what is being measured and the applicable contract, regulation, or reporting requirement. Those procedures account for details that a single constant cannot: product group, density range, temperature range, and the convention used for observed and base density.

  • Confusing API gravity with specific gravity: API gravity is a derived scale; it is not the density itself. Convert through specific gravity when applying a correction.
  • Mixing temperature units: This calculator accepts °C only. A Fahrenheit value entered as Celsius makes the answer invalid.
  • Assuming the coefficient is universal: Different petroleum products expand differently. The 0.00064 factor is deliberately approximate.
  • Rounding too early: Keep the original measured value and unrounded intermediate results through the correction, then round for display or reporting.
  • Using an approximate answer for a formal ticket: Use the method required by the applicable standard, contract, or authority when the result affects inventory, transfer, tax, or quality decisions.

A useful reasonableness check is direction: for a typical liquid, warming reduces density and raises its uncorrected API gravity. Correcting a warm observation back to 60°F should generally lower the API number. Unexpected direction or a large change can signal a unit, input, or method mismatch. This check does not establish that a result is compliant.

Frequently Asked Questions

What temperature is API gravity corrected to?
Often 60°F (15.56°C) for petroleum liquids, but the required reference temperature depends on the governing method or reporting context. Confirm the base temperature stated in the source or standard.

How do I correct API gravity from Fahrenheit?
Convert the observed temperature to Celsius with (°F − 32) × 5 / 9, then enter that temperature and the observed API gravity. For official work, use the relevant standard’s prescribed tables or procedure rather than relying on this approximation.

Does API gravity increase when temperature increases?
For a typical petroleum liquid, warming lowers density, so its uncorrected API gravity generally increases. A temperature correction to a cooler reference point will usually reduce that observed API value.

Can I convert API gravity to specific gravity?
Yes. At the same reference temperature, SG = 141.5 / (API + 131.5). Be sure the specific gravity and API value refer to the same temperature basis.

Is this calculator suitable for custody transfer?
No. It uses a fixed, generic approximation and does not implement product-specific standard tables or required measurement procedures. Use the applicable petroleum measurement standard and documented measurement data for custody transfer or regulatory reporting.

Related

Formula used
in api | Observed API gravity | °API | 35 | -100
in tc | Sample temperature | °C | 20 | -273.15
out api60 | Estimated API gravity at 60°F | °API | ((141.5 / (141.5 / (api + 131.5) + 0.00064 * (tc - 15.5555556))) - 131.5) | 2
out sg60 | Estimated specific gravity at 60°F | - | 141.5 / (api60 + 131.5) | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →