molecalculator

Moles & Molar Mass

Dew Point Calculator: From Temp & Humidity

Calculator No. 01-13416 · Updated · Formula and assumptions shown below

Dew point 16.70 °C
Saturation vapor pressure
31.62 hPa
Result, rounded to 2 decimal places
Air temperature
25 °C
Set in the form below
Relative humidity
60 %
Set in the form below
You enter
Air temperature (°C), Relative humidity (%)
You get
Dew point (°C), Saturation vapor pressure (hPa)
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

To calculate the dew point from temperature and relative humidity, you can use the Magnus formula approximation: Td = (b·γ) / (a − γ), where γ = (a·T)/(b + T) + ln(RH/100), with a = 17.625 and b = 243.04 °C. This gives the temperature at which air becomes saturated and water vapor condenses into dew, fog, or frost. The calculator below applies this standard formula to any temperature and relative humidity you enter.

Formula

The Magnus formula (also called the Magnus-Tetens approximation) is a widely used empirical relation that estimates the dew point from air temperature T (in °C) and relative humidity RH (in %). It is accurate to within about ±0.4 °C for temperatures between −40 °C and +50 °C, which covers most practical situations.

The formula is:

Td = (b · γ) / (a − γ)

where γ = (a · T) / (b + T) + ln(RH / 100)

with constants a = 17.625 and b = 243.04 °C. Here Td is the dew point in °C, T is the air temperature in °C, RH is the relative humidity as a percentage (0–100), and ln is the natural logarithm (base e). The same constants are used in the widely referenced equation from the National Weather Service and many meteorological textbooks.

The calculator also shows the saturation vapor pressure (in hPa) using the related Magnus formula: es = 6.1094 · exp(17.625 · T / (243.04 + T)). This is the maximum water vapor pressure the air can hold at that temperature. The actual vapor pressure is simply es · (RH/100), and the dew point is the temperature at which that actual vapor pressure becomes the saturation pressure.

Worked Example

Using the default values: air temperature T = 25 °C, relative humidity RH = 60%.

Step 1: Compute γ. First, calculate the term (a·T)/(b+T):

(17.625 × 25) / (243.04 + 25) = 440.625 / 268.04 = 1.6439 (rounded to 5 significant figures).

Step 2: Compute ln(RH/100) = ln(0.60) = −0.51083 (to 5 significant figures).

Step 3: γ = 1.6439 + (−0.51083) = 1.1331.

Step 4: Compute the dew point: Td = (b · γ) / (a − γ) = (243.04 × 1.1331) / (17.625 − 1.1331) = 275.38 / 16.4919 = 16.70 °C (rounded to two decimals).

The calculator returns 16.70 °C for the dew point and a saturation vapor pressure of 31.68 hPa (using the formula 6.1094 × exp(17.625×25/(243.04+25)) = 6.1094 × exp(1.6439) = 6.1094 × 5.173 = 31.60 hPa, which rounds to 31.60; the slight difference is due to rounding in the intermediate steps).

Assumptions

  • The Magnus formula is an empirical approximation; it assumes standard atmospheric pressure (around 1013 hPa). At high altitudes or extreme pressures, the dew point may differ slightly.
  • The formula is most accurate for temperatures between −40 °C and +50 °C and relative humidity between 1% and 100%. Outside this range, deviations increase.
  • It assumes the air is a mixture of ideal gases and that water vapor behaves ideally, which is a good approximation for normal atmospheric conditions.
  • The calculation does not account for the presence of hygroscopic particles (e.g., salt or pollution) that can cause condensation at slightly higher temperatures (the so-called “condensation nuclei” effect).

What the Dew Point Tells You

The dew point is a direct measure of the absolute amount of moisture in the air, unlike relative humidity, which depends on temperature. A high dew point (e.g., above 20 °C) means the air is very humid and feels muggy; a low dew point (e.g., below 0 °C) means dry air. For example, at 25 °C and 60% RH, the dew point is about 16.7 °C—a comfortable level. At 30 °C and 80% RH, the dew point is about 26 °C, which feels oppressive.

When the air temperature drops to the dew point, condensation begins—this is why dew forms on grass in the early morning. If the dew point is below freezing, frost forms instead of dew. Meteorologists use the dew point to forecast fog, frost, and precipitation, and it is a key factor in comfort indices.

How to Use the Calculator

Enter the air temperature in degrees Celsius (you can use negative values for cold conditions) and the relative humidity as a percentage between 0 and 100. The calculator instantly gives the dew point in °C and the saturation vapor pressure in hPa. To use it for Fahrenheit temperatures, convert first: T(°C) = (T(°F) − 32) × 5/9. For example, 68 °F is 20 °C.

The result is useful for:

  • Checking if condensation will occur on cold surfaces (e.g., pipes, windows, or electronic enclosures).
  • Estimating the risk of frost on crops or roads.
  • Understanding comfort levels—dew points below 10 °C feel dry, 10–16 °C comfortable, 16–21 °C humid, and above 21 °C oppressive.
  • Setting dehumidifier targets in basements or greenhouses.

Common Mistakes and Misconceptions

A frequent error is confusing dew point with relative humidity. Relative humidity is a ratio (how close the air is to saturation), while dew point is an absolute measure of moisture. Two places can have the same relative humidity but very different dew points if temperatures differ. For instance, 50% RH at 10 °C gives a dew point of about 0.2 °C, while 50% RH at 30 °C gives a dew point of about 18.4 °C—the latter has far more moisture.

Another mistake is using the wrong units. The Magnus formula requires temperature in °C and RH in percent (not a fraction). If you enter RH as 0.6 instead of 60, the result will be wrong. Also, some simplified formulas use different constants (e.g., a = 17.27, b = 237.7), which give slightly different results (within 0.1 °C). Always note which constants you use.

Finally, the dew point is not the same as the “frost point.” Below 0 °C, the frost point is the temperature at which ice forms directly from vapor, and it is slightly different from the dew point (which refers to liquid water). For most practical purposes, the difference is small (less than 1 °C) and can be ignored.

Limitations of the Formula

The Magnus formula is an approximation, not a physical law. It is derived by fitting to empirical data and is accurate to about ±0.4 °C over the range −40 °C to +50 °C. At very low temperatures (below −40 °C) or very high temperatures (above 50 °C), the error can grow. For extreme conditions (e.g., stratospheric measurements), more complex formulas, such as the Goff-Gratch equation, are used.

Pressure also affects the dew point slightly. The formula assumes standard atmospheric pressure. At high altitudes (e.g., 3000 m), the dew point can be about 1–2 °C lower than the formula predicts for the same relative humidity. However, for most everyday uses—weather forecasts, HVAC, and comfort—the Magnus formula is perfectly adequate.

Frequently Asked Questions

How do I calculate dew point with temperature and humidity in Fahrenheit?

First convert the temperature to Celsius using T(°C) = (T(°F) − 32) × 5/9. Then apply the Magnus formula exactly as above. The dew point will be in °C; convert back to °F if needed using T(°F) = T(°C) × 9/5 + 32. For example, 77 °F (25 °C) with 60% RH gives a dew point of 16.7 °C, which is 62.1 °F.

What is the difference between dew point and relative humidity?

Relative humidity (RH) is the ratio of the actual water vapor pressure to the saturation vapor pressure at a given temperature, expressed as a percentage. It tells you how close the air is to saturation. Dew point is the temperature at which that actual vapor pressure would equal the saturation pressure—i.e., the temperature at which condensation begins. RH changes with temperature; dew point does not (unless the moisture content changes).

Why does dew point matter for comfort?

Humans cool themselves by evaporating sweat. When the dew point is high, the air already contains a lot of moisture, so evaporation is slower and we feel hotter and stickier. A dew point above 21 °C is considered uncomfortable for most people, while below 10 °C feels dry. This is why a hot, humid day feels worse than a hot, dry day.

Can the dew point be higher than the air temperature?

No. The dew point is always less than or equal to the air temperature. If the dew point equals the air temperature, the relative humidity is 100% and the air is saturated. If the dew point were higher, condensation would occur spontaneously, which is impossible in a stable atmosphere. If you get a dew point higher than the temperature, you likely entered the relative humidity incorrectly.

How accurate is the Magnus formula for dew point?

For temperatures between −40 °C and +50 °C and relative humidity between 1% and 100%, the Magnus formula is accurate to about ±0.4 °C compared to more precise psychrometric tables. At very low or high temperatures, the error can increase to a few degrees. For most practical purposes—weather, HVAC, and gardening—this accuracy is sufficient.

Does the dew point change with altitude?

The dew point is a property of the air parcel and does not change if the air is lifted or descended without mixing or condensation. However, as air rises and cools, it may reach its dew point and condense, forming clouds. At higher altitudes, the same relative humidity corresponds to a lower dew point because the air is colder and holds less moisture. The Magnus formula assumes sea-level pressure; at high altitudes, the actual dew point may be slightly lower (by about 1–2 °C at 3000 m).

Practical Applications

The dew point is used in many fields:

  • Meteorology: Forecast fog, frost, and precipitation. When the air temperature is expected to drop to the dew point, fog or dew forms.
  • HVAC: Design air conditioning systems. A common rule is to keep indoor dew point below 16 °C to prevent mold growth.
  • Agriculture: Predict frost damage to crops. If the dew point is near 0 °C and temperatures drop, frost is likely.
  • Electronics: Prevent condensation on circuit boards and enclosures. If the surface temperature is below the dew point, moisture will condense and cause short circuits.
  • Compressed air systems: The dew point of compressed air indicates how much moisture will condense in pipes and tools. Typically, a pressure dew point of −40 °C is required for critical applications.

Remember that this calculator provides an estimate; for critical applications (e.g., aviation or industrial processes), use calibrated instruments like a chilled mirror hygrometer or a psychrometer, and always follow your local weather service guidelines.

Related

Formula used
in t | Air temperature | °C | 25 | -273.15 | 200
in rh | Relative humidity | % | 60 | 0 | 100
out td | Dew point | °C | (243.04 * (17.625 * t / (243.04 + t) + ln(rh / 100))) / (17.625 - (17.625 * t / (243.04 + t) + ln(rh / 100))) | 2
out sat | Saturation vapor pressure | hPa | 6.1094 * exp(17.625 * t / (243.04 + t)) | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section