Calculator No. 01-13370 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

To calculate gas flow rate from pressure, you need more than just pressure—you need the pressure difference (ΔP) across a known restriction (like an orifice or pipe), plus gas properties and geometry. The simplest approach for many lab and industrial situations is the orifice flow equation: Q = C × A × √(2 × ΔP / ρ), where Q is volumetric flow (m³/s), C is the discharge coefficient (dimensionless, often 0.6–0.8), A is the orifice cross-sectional area (m²), ΔP is the pressure drop (Pa), and ρ is the gas density (kg/m³). This calculator applies that formula for you, taking inputs for pressure drop, orifice diameter, discharge coefficient, and gas density, and returns the flow rate in liters per minute.

Formula

The core formula used here is the orifice flow equation for incompressible, turbulent flow:

Q = C × A × √(2 × ΔP / ρ)

Where:

  • Q = volumetric flow rate (m³/s, converted to L/min in the output)
  • C = discharge coefficient (dimensionless, typically 0.6–0.8 for sharp-edged orifices)
  • A = cross-sectional area of the orifice (m²) = π × (D/2)², with D in meters
  • ΔP = pressure drop across the orifice (Pa; note 1 kPa = 1000 Pa)
  • ρ = gas density (kg/m³) at the actual temperature and pressure

This equation assumes the gas behaves as an incompressible fluid, which is reasonable for low pressure drops (less than about 10–15% of the absolute inlet pressure) and moderate velocities. For higher pressure drops or compressible gases, a more complex version (e.g., using the ideal gas law and an expansion factor) is needed.

Worked Example

Using the default values from the calculator:

  • Pressure drop ΔP = 10 kPa = 10,000 Pa
  • Orifice diameter D = 5 mm = 0.005 m
  • Discharge coefficient C = 0.62
  • Gas density ρ = 1.225 kg/m³ (air at ~15°C, 1 atm)

Step 1: Calculate the orifice area:

A = π × (0.005/2)² = π × (0.0025)² = π × 6.25 × 10⁻⁶ = 1.9635 × 10⁻⁵ m²

Step 2: Calculate the velocity term:

√(2 × 10,000 / 1.225) = √(20,000 / 1.225) = √(16326.53) = 127.77 m/s

Step 3: Multiply together:

Q = 0.62 × 1.9635 × 10⁻⁵ × 127.77 = 0.62 × 2.508 × 10⁻³ = 1.555 × 10⁻³ m³/s

Step 4: Convert to L/min (1 m³ = 1000 L, 1 min = 60 s):

Q = 1.555 × 10⁻³ × 1000 × 60 = 93.3 L/min

The calculator gives 93.30 L/min, matching this result.

Assumptions

  • Steady, turbulent, incompressible flow (valid for ΔP < ~10–15% of absolute inlet pressure)
  • Sharp-edged circular orifice with a uniform discharge coefficient
  • Gas density constant across the orifice (isothermal, low Mach number)
  • No friction losses other than those captured by the discharge coefficient
  • The gas is a single-phase, non-reactive ideal gas at the given density

When to Use This Calculator

This calculator is ideal for estimating flow through a simple restriction—like a pinhole, orifice plate, or nozzle—where you know the pressure drop and the gas density. Common applications include:

  • Calibrating a rotameter or mass flow controller in a lab
  • Sizing a vent or purge line in a chemical process
  • Estimating leak rates from a pressurized vessel through a small hole
  • Designing a simple gas delivery system for an experiment

For pipe flow (not an orifice), you would need the Darcy–Weisbach equation with friction factor, which depends on pipe length, roughness, and Reynolds number. This calculator is not for that.

How to Read the Result

The first output is volumetric flow in liters per minute at the conditions you specified. This is the volume of gas passing per minute, but remember that gas volume changes with temperature and pressure. If you need mass flow (g/s), the second output gives that directly, which is more meaningful for chemical reactions or dosing because it doesn’t change with temperature.

For example, 93.3 L/min of air at 15°C corresponds to about 1.91 g/s (as shown). If you double the pressure drop, flow increases by √2 ≈ 1.41 times, not double, because the equation has a square root.

Common Mistakes and Pitfalls

  • Unit mix-ups: Forgetting to convert kPa to Pa (multiply by 1000) or mm to m (divide by 1000) is the most frequent error. Always check your units.
  • Using gauge pressure instead of pressure drop: The ΔP is the difference between upstream and downstream pressure, not the absolute pressure. If you have a tank at 100 kPa gauge venting to atmosphere, ΔP is 100 kPa, not 101.325 kPa.
  • Ignoring compressibility: For high pressure drops (ΔP > 10–15% of inlet absolute pressure), the gas expands and accelerates, so the simple formula overestimates flow. Use a compressible flow equation or an expansion factor.
  • Wrong discharge coefficient: The value of C varies with orifice geometry and Reynolds number. For a sharp-edged orifice, 0.62 is typical, but for a rounded entrance it can be 0.9–0.98. If you don’t know, use 0.62 and note the uncertainty.
  • Assuming air density always: Density changes with temperature and pressure. For other gases, use the ideal gas law: ρ = P × MW / (R × T), where P is absolute pressure in Pa, MW is molar mass in kg/mol, R = 8.314 J/(mol·K), T in Kelvin. For air at 20°C and 1 atm, ρ ≈ 1.204 kg/m³.

Limits of the Formula

The orifice equation is a simplified model. In real systems, flow can be affected by pipe length upstream, turbulence, and the shape of the orifice edge. The discharge coefficient captures some of this, but it is not a universal constant. For precise measurements, you need a calibrated flow meter (e.g., a laminar flow element or a sonic nozzle). Also, the equation assumes a constant density, which fails for high-pressure gas systems where the gas is significantly compressed. For such cases, use the ISO 5167 standard for orifice plates, which includes an expansion factor.

For very low pressure drops (ΔP < ~1 kPa), flow may become laminar, and the discharge coefficient changes. In that regime, a different correlation (e.g., Hagen–Poiseuille for a capillary) is more accurate.

Safety and Accuracy Notes

When working with pressurized gas, always follow your lab method, the safety data sheet (SDS) and your supervisor. Never exceed the pressure rating of your tubing, fittings, or vessels. Use appropriate regulators and relief valves. The flow rates calculated here are theoretical; always verify with a calibrated flow meter before using the gas in a process. For toxic or flammable gases, ensure proper ventilation and leak detection.

Frequently Asked Questions

Can I calculate flow rate from just the tank pressure?

No—you need the pressure drop across a restriction. If you have a tank at 10 bar and a valve that opens to atmosphere, the ΔP is about 9 bar (absolute pressure difference). Without a known orifice or valve coefficient, you cannot compute flow. You need either the orifice size or a flow coefficient (Cv) from the valve manufacturer.

What is the difference between volumetric flow and mass flow?

Volumetric flow (L/min) measures volume per time, which changes with temperature and pressure. Mass flow (g/s) measures mass per time, which is constant for a given molar flow. For chemical reactions, mass flow is more useful because it directly relates to moles. To convert, multiply volumetric flow by gas density at the actual conditions.

How do I find the gas density for my specific gas?

Use the ideal gas law: ρ = (P × MW) / (R × T), where P is absolute pressure in Pa, MW is molar mass in kg/mol (e.g., nitrogen 0.028014 kg/mol), R = 8.314 J/(mol·K), T in Kelvin. For example, nitrogen at 20°C and 101325 Pa: ρ = (101325 × 0.028014) / (8.314 × 293.15) = 1.164 kg/m³.

Does temperature affect the flow rate?

Yes, because temperature changes gas density. Warmer gas is less dense, so for the same pressure drop and orifice, the volumetric flow increases (since √(1/ρ) is larger), but the mass flow decreases. Always specify the temperature when reporting flow rates.

What is a discharge coefficient and how do I choose it?

The discharge coefficient (C) accounts for energy losses and flow contraction at the orifice. For a sharp-edged circular orifice, C ≈ 0.62. For a well-rounded nozzle, C can be 0.95–0.98. If you are unsure, use 0.62 and expect ±10–20% accuracy. For critical flow (choked), the coefficient may differ.

When is the gas flow choked?

Choked flow occurs when the downstream pressure is less than about half the upstream absolute pressure (for air, the critical pressure ratio is ~0.528). At that point, the flow velocity reaches the speed of sound, and further reducing downstream pressure does not increase flow. The simple orifice formula no longer applies; use the choked flow equation instead.

Related

Formula used
in dP | Pressure drop (ΔP) | kPa | 10 | 0
in D | Orifice diameter | mm | 5 | 0
in C | Discharge coefficient | - | 0.62 | 0.1
in rho | Gas density | kg/m³ | 1.225 | 0
out Q | Volumetric flow rate | L/min | (C * (pi * (D/1000)^2 / 4) * sqrt(2 * (dP * 1000) / rho)) * 60000 | 2
out Qm | Mass flow rate | g/s | (C * (pi * (D/1000)^2 / 4) * sqrt(2 * (dP * 1000) / rho)) * rho * 1000 | 3

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.