Calculate R Value From Thermal Conductivity

Calculator No. 01-10350 · Updated · Formula and assumptions shown below

R-value (SI) 2.500 m²·K/W
R-value (US, per inch)
14.20 h·ft²·°F/Btu
= (Thickness ÷ Thermal conductivity (k)) × 5.678263
Thickness
0.1 m
Set in the form below
Thermal conductivity (k)
0.04 W/(m·K)
Set in the form below
You enter
Thickness (m), Thermal conductivity (k) (W/(m·K))
You get
R-value (SI) (m²·K/W), R-value (US, per inch) (h·ft²·°F/Btu)
Rounding
3 dp · 2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

To calculate an R-value from thermal conductivity, divide the material thickness (in meters) by its thermal conductivity (in W/m·K): R = thickness ÷ k. For example, 0.1 m of a material with k = 0.04 W/m·K gives R = 2.5 m²·K/W. This page provides a calculator that does this conversion, plus explains the physics, units, and common pitfalls.

Formula

The R-value (thermal resistance) is defined as thickness divided by thermal conductivity:

R = L / k

  • R – thermal resistance in m²·K/W (SI) or h·ft²·°F/Btu (US)
  • L – thickness of the material in meters (m) or inches (in)
  • k – thermal conductivity in W/(m·K) (SI) or Btu·in/(h·ft²·°F) (US)

To convert SI R-value to US R-value (per inch basis): multiply by 5.678263. To convert US R-value (per inch) to SI: divide by 5.678263. The calculator above uses the SI formula and shows both results.

Worked Example

Using the default values: thickness = 0.1 m, k = 0.04 W/(m·K).

  1. R (SI) = 0.1 / 0.04 = 2.5 m²·K/W
  2. R (US) = 2.5 × 5.678263 = 14.20 h·ft²·°F/Btu (per inch)

The calculator gives 2.500 m²·K/W and 14.20 US R-value. Note that the US value is per inch of thickness; for a 0.1 m (about 4 inches) layer, the total US R-value would be 14.20 × 4 ≈ 56.8.

Assumptions

  • Steady-state heat flow (no time dependence).
  • Homogeneous material – k is constant throughout.
  • One-dimensional heat transfer through the thickness.
  • No convective or radiative effects inside the material.
  • Thickness is measured perpendicular to heat flow.

Understanding Thermal Conductivity and R-Value

Thermal conductivity (k) measures how well a material conducts heat – lower k means better insulation. R-value measures how well a specific layer resists heat flow – higher R means better insulation. The two are inversely related through thickness. For example, fiberglass batts have k ≈ 0.04 W/m·K, while copper has k ≈ 400 W/m·K – a 10,000-fold difference. That is why a 1 cm copper plate has an R-value of only 0.000025 m²·K/W, while 1 cm of fiberglass gives 0.25 m²·K/W.

In building science, R-values are often quoted per inch (US) or per meter (SI). A typical 2×4 wall with fiberglass insulation has R-13 (US) or about 2.3 m²·K/W. The calculator above lets you switch between systems.

How to Use the Calculator

Enter the thickness of the material layer and its thermal conductivity. The calculator outputs the R-value in SI units (m²·K/W) and US units (h·ft²·°F/Btu per inch). For a multi-layer assembly, compute each layer’s R-value separately and add them: R_total = R1 + R2 + R3 … This is valid for series heat flow (layers stacked). For parallel paths (e.g., studs and insulation), you need area-weighted calculations, which are more complex.

When reading results, remember that US R-values are usually given per inch of material. For example, if you have 6 inches of fiberglass (k=0.04 W/m·K), first compute SI R = 0.1524 / 0.04 = 3.81 m²·K/W, then US total = 3.81 × 5.678 = 21.6 h·ft²·°F/Btu. Many building codes specify minimum R-values for walls, roofs, and floors – check local codes.

Common Mistakes and Misconceptions

  • Unit mix-ups: Using W/(m·K) with thickness in inches, or mixing SI and US units. Always convert thickness to meters when using SI k.
  • Confusing R-value with U-value: U-value (thermal transmittance) is the reciprocal of R-value (U = 1/R). Lower U is better insulation.
  • Assuming k is constant: k varies with temperature, moisture content, and density. For example, wet insulation conducts more heat.
  • Forgetting that R-value is per unit thickness: A 2-inch layer has twice the R-value of a 1-inch layer of the same material.
  • Adding R-values without considering series vs parallel: In a wall with studs, the studs act as thermal bridges – the total R is lower than the sum of insulation R-values alone.

When to Use This Calculation

This calculation is essential for:

  • Comparing insulation materials (e.g., fiberglass vs. foam board vs. cellulose).
  • Designing building envelopes to meet energy codes.
  • Estimating heat loss through walls, roofs, and floors.
  • Selecting materials for industrial insulation (pipes, tanks, ovens).
  • Understanding product labels – many insulation products list R-value per inch.

For a complete heat loss calculation, you also need the temperature difference and surface area: Q = (ΔT × A) / R_total. This calculator gives you the R-value part, which is the material property.

Limitations and Real-World Factors

The simple R = L/k formula assumes steady-state, one-dimensional heat flow. In practice:

  • Thermal conductivity changes with temperature – for most building materials, k increases slightly with temperature.
  • Moisture drastically reduces R-value – wet insulation can lose 50% or more of its thermal resistance.
  • Air gaps, compression, and installation defects create thermal bridges.
  • Radiative heat transfer can be significant in low-density insulation (e.g., reflective foils).
  • For anisotropic materials (wood, some composites), k depends on direction.

For accurate building design, use tested R-values from manufacturers (e.g., ASTM C518) rather than theoretical k values. The calculator is a useful approximation for homogeneous materials.

Frequently Asked Questions

How do I convert R-value from SI to US units?

Multiply the SI R-value (m²·K/W) by 5.678263 to get US R-value (h·ft²·°F/Btu). For example, R-2.5 SI becomes 14.2 US. Conversely, divide US by 5.678263 to get SI.

What is a good R-value for a wall?

It depends on climate. In the US, typical recommendations: R-13 to R-21 for walls in most climates, R-30 to R-60 for attics. In SI units, that’s roughly 2.3 to 3.7 m²·K/W for walls, 5.3 to 10.6 for attics. Check local building codes.

Can I add R-values of different materials?

Yes, for layers in series (one after another), simply add the individual R-values. For example, a wall with R-13 insulation plus R-3 sheathing has total R-16. For parallel paths (studs and insulation), use area-weighted averages.

Why does my insulation have an R-value per inch?

R-value per inch is a material property that allows easy comparison. To get the total R-value, multiply the per-inch value by the thickness in inches. For example, R-3.5 per inch foam board at 2 inches thick gives R-7.

What is the difference between R-value and U-value?

U-value is the thermal transmittance, the rate of heat transfer through a material per unit area per degree temperature difference. It is the reciprocal of R-value (U = 1/R). Lower U-value means better insulation. U-values are often used for windows and doors.

Does thermal conductivity change with thickness?

No, thermal conductivity is an intrinsic material property – it does not depend on thickness. However, the R-value increases proportionally with thickness because R = L/k. For very thick layers, convection or radiation may affect overall heat transfer, but the material’s k remains constant.

Related

Formula used
in m | Thickness | m | 0.1 | 0.0001
in k | Thermal conductivity (k) | W/(m·K) | 0.04 | 0.001
out r | R-value (SI) | m²·K/W | m / k | 3
out r_imperial | R-value (US, per inch) | h·ft²·°F/Btu | (m / k) * 5.678263 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.