The coefficient of thermal conductivity (k) is calculated with the formula k = Q·L / (A·ΔT·t), where Q is the heat transferred, L is the thickness of the material, A is the cross-sectional area, ΔT is the temperature difference, and t is the time. This gives the thermal conductivity in watts per meter-kelvin (W/(m·K)). Enter the heat flow, dimensions, and temperature gradient into the calculator below to find k directly.
Formula
The thermal conductivity coefficient (k) is defined by Fourier’s law of heat conduction. In its practical form for a flat slab of material:
k = (Q × L) / (A × ΔT × t)
- Q – heat energy transferred through the material, in joules (J)
- L – thickness of the material in the direction of heat flow, in meters (m)
- A – cross-sectional area perpendicular to heat flow, in square meters (m²)
- ΔT – temperature difference between the two faces, in kelvin (K) or °C (the size of a kelvin equals a degree Celsius)
- t – time over which the heat flows, in seconds (s)
The result k is expressed in watts per meter-kelvin (W/(m·K)). This is the standard SI unit. Sometimes you’ll see W/(m·°C) – numerically identical because a 1 K difference equals a 1 °C difference.
Worked Example
Using the default values from the calculator: Q = 1500 J, L = 0.05 m, A = 0.02 m², ΔT = 30 K, t = 60 s.
- Multiply heat by thickness: 1500 × 0.05 = 75 J·m
- Multiply area by temperature difference and time: 0.02 × 30 × 60 = 36 m²·K·s
- Divide: 75 / 36 = 2.0833 W/(m·K)
The calculator rounds to 4 decimal places, giving 2.0833 W/(m·K). This value is typical of a dense ceramic or a metal oxide – far lower than pure copper (about 385 W/(m·K)) but much higher than air (about 0.026 W/(m·K)).
Assumptions
- Steady-state heat flow (temperatures don’t change with time)
- One-dimensional heat flow perpendicular to the faces
- Uniform material – no voids, layers, or composites
- Constant k over the temperature range (true for many solids over modest ranges)
- No heat loss from the sides of the sample
What the Result Means
Thermal conductivity measures how easily heat moves through a material. A high k (like 400 W/(m·K) for silver) means the material conducts heat very well – think of a metal spoon handle getting hot in a pot. A low k (like 0.03 W/(m·K) for foam insulation) means it resists heat flow – think of a Styrofoam cup keeping your coffee warm.
In engineering, k is the key property for:
- Designing heat sinks for electronics (you want high k)
- Choosing insulation for buildings (you want low k)
- Calculating heat loss through pipes, furnace walls, or refrigerator panels
- Selecting materials for heat exchangers
The inverse of thermal conductivity is thermal resistivity (1/k). When you see “R-value” on insulation, it’s essentially thickness divided by k (R = L/k), so a thicker layer or a lower k gives a higher R-value.
Common Mistakes and Unit Mix-ups
The most frequent error is mixing units. If you measure thickness in centimeters and area in square meters, the result will be off by a factor of 100. Always convert to meters and square meters before using the formula.
- 1 cm = 0.01 m
- 1 mm = 0.001 m
- 1 cm² = 0.0001 m²
- 1 W = 1 J/s, so if you have power instead of heat, multiply by time to get Q
Another common mistake is using the temperature difference in °C instead of K. As noted, the size of the unit is the same, so ΔT in °C can be used directly – but absolute temperatures (like 300 °C) must be converted to kelvin if you’re using the absolute form of the equation.
Also, be careful: the formula above gives the average k over the temperature range. For many materials, k changes with temperature – metals generally decrease in k as temperature rises, while insulators often increase. For precise work, you need k(T) data.
How to Measure Thermal Conductivity
In the lab, k is measured using a guarded hot plate or a heat flow meter. A flat sample of known thickness is placed between a hot plate and a cold plate. You measure:
- The steady-state heat input (Q/t) supplied to the hot plate
- The temperature difference ΔT across the sample
- The area A and thickness L of the sample
Then plug those numbers into the formula. For liquids and gases, methods like the transient hot-wire technique are used. For thin films, laser flash analysis measures thermal diffusivity, and k is then calculated using k = α·ρ·cp (where α is diffusivity, ρ is density, and cp is specific heat).
Typical Values and Comparisons
To give you a sense of scale, here are approximate thermal conductivities at room temperature (in W/(m·K)):
- Diamond: ~1000–2000 (best solid conductor)
- Silver: 429
- Copper: 385
- Aluminum: 205
- Iron: 80
- Stainless steel: ~16
- Glass: ~1.0
- Water: 0.6
- Wood (oak): ~0.15
- Air (still): 0.026
- Aerogel: ~0.02 (best insulator)
Notice the huge range – over five orders of magnitude. That’s why material choice matters so much in thermal design. Also note that “conductivity” here is a material property, not the same as electrical conductivity, though metals tend to be good at both.
Limitations of the Formula
The simple formula works well for flat slabs and steady heat flow, but real-world situations are often more complex:
- For cylindrical pipes or spherical shells, the area changes with radius, so the formula becomes k = Q·ln(r2/r1) / (2πL·ΔT·t) for a pipe.
- For transient (time-dependent) heating, you need the heat equation, not this steady-state version.
- For composites or layered materials, you must calculate an effective k, which depends on the arrangement (series or parallel).
- For anisotropic materials (like wood or graphite), k differs with direction.
In those cases, this calculator gives a first approximation, but you should use the appropriate geometry-specific equation.
Frequently Asked Questions
What is the difference between thermal conductivity and thermal resistance?
Thermal conductivity (k) is a material property – how well a specific substance conducts heat. Thermal resistance (R) is a property of a particular object or layer – it equals thickness divided by conductivity (R = L/k). A thick piece of copper can have a higher thermal resistance than a thin piece of steel, even though copper’s k is higher. R-value in building insulation is exactly this: R = L/k, with units of m²·K/W.
Why is copper used in heat sinks if silver is a better conductor?
Silver conducts heat about 10% better than copper, but it costs roughly 100 times more. For most applications, the performance gain doesn’t justify the price. Copper is also stronger and easier to machine. That’s why you see copper heat pipes and aluminum heat sinks (aluminum is cheaper and lighter, even though it conducts only about half as well as copper).
Does thermal conductivity change with temperature?
Yes, for most materials. In metals, k generally decreases as temperature rises because electron scattering increases. In insulators, k often increases with temperature because lattice vibrations (phonons) carry heat more effectively at higher temperatures. For example, copper’s k drops from about 385 W/(m·K) at 20 °C to about 370 at 100 °C. For precise engineering, you need k(T) data for your specific material.
How do I convert thermal conductivity from W/(m·K) to other units?
You might see BTU/(h·ft·°F) in US engineering. To convert: 1 W/(m·K) = 0.5778 BTU/(h·ft·°F). Also, 1 W/(m·K) = 0.8598 kcal/(h·m·°C). The SI unit is always preferred in scientific work. If you’re using the formula above, stick to watts, meters, and kelvin to avoid errors.
What is the thermal conductivity of air?
Still air has a very low thermal conductivity of about 0.026 W/(m·K) at room temperature. That’s why double-pane windows and foam insulation trap air – the air pockets slow heat transfer. However, if air is moving (convection), the effective heat transfer is much higher because hot air physically carries heat away. That’s why you feel colder in a breeze even though the air temperature is the same.
Can I use this formula for liquids and gases?
Yes, the same formula applies to all states of matter as long as heat transfer is by conduction only. In liquids and gases, convection often dominates, so the formula only works if the fluid is stationary (e.g., a thin layer between plates). For moving fluids, you need convective heat transfer coefficients, not just k.
Related
Formula used
in q | Heat transferred (Q) | J | 1500 | 0 in l | Thickness (L) | m | 0.05 | 0 in a | Cross-sectional area (A) | m² | 0.02 | 0 in dt | Temperature difference (ΔT) | K | 30 | 0 in t | Time (t) | s | 60 | 0 out k | Thermal conductivity | W/(m·K) | (q * l) / (a * dt * t) | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- QPP Calculator Canada: How It Works & How to Use It
- PPP Calculator World Bank: How It Works & How to Use It2,000.00
- PPP Calculator: India vs USA Cost Comparison1,000.00 USD
- PPP Calculator USD to INR: How It Works2,335 INR
- PPP Calculator India vs Dubai: Real Cost Comparison8,954.58 AED
- PPP Calculator India vs UK: Real Cost Comparison103.63 GBP