This calculator converts an R-value (thermal resistance) to a U-value (thermal transmittance) using the simple reciprocal relationship U = 1/R. You enter the R-value in imperial units (ft²·°F·h/BTU) or metric units (m²·K/W), and the calculator returns the U-value in the corresponding unit, with the option to see the equivalent in the other system.
Formula
The fundamental relationship is:
U = 1 / R
Where:
- U = thermal transmittance, in BTU/(ft²·°F·h) for imperial, or W/(m²·K) for metric
- R = thermal resistance, in ft²·°F·h/BTU for imperial, or m²·K/W for metric
To convert between the two unit systems:
1 m²·K/W = 5.678263 ft²·°F·h/BTU
So if you have an R-value in imperial units, the metric U-value is:
U (W/m²·K) = 1 / (R_imperial / 5.678263)
Equivalently, if you have R in metric units, the imperial U-value is:
U (BTU/ft²·°F·h) = 1 / (R_metric × 5.678263)
The calculator above uses the imperial R-value as the primary input (default 13, a common attic insulation value). The first output is the U-value in imperial units; the second output converts that to metric.
Worked Example
Using the default R-value of 13 ft²·°F·h/BTU:
- Start with R = 13 ft²·°F·h/BTU.
- Compute U_imperial = 1 / 13 = 0.076923 BTU/(ft²·°F·h).
- Convert to metric: U_metric = 0.076923 × 5.678263 = 0.436789 W/(m²·K).
So an R-value of 13 corresponds to a U-value of approximately 0.077 BTU/(ft²·°F·h) or 0.437 W/(m²·K).
Assumptions
- Steady-state heat transfer (no thermal mass effects).
- One-dimensional heat flow perpendicular to the surface.
- The R-value is the total thermal resistance of the assembly (including all layers).
- The conversion factor 5.678263 is exact (1 BTU/(ft²·°F·h) = 5.678263 W/(m²·K)).
Why Convert R to U?
R-value and U-value are two sides of the same coin. R-value measures resistance to heat flow – the higher the R, the better the insulation. U-value measures how much heat passes through a material per unit area per degree of temperature difference – the lower the U, the better the insulation. In the United States, building codes and insulation products are typically rated by R-value. In Europe and many other parts of the world, window and door manufacturers quote U-values (often called U-factor). If you are comparing products from different countries or working on an international project, you need to convert between the two.
For example, a window with a U-factor of 0.30 BTU/(ft²·°F·h) has an R-value of about 3.33 – much lower than the R-13 of a typical insulated wall. That is why windows are often the weakest thermal link in a building envelope.
How to Choose the Right Unit System
Use the unit system that matches your source data. If you are reading an American insulation label, it will show R-value in ft²·°F·h/BTU. If you are reading a European window spec, it will show U-value in W/(m²·K). The calculator lets you choose the input system, but it always outputs both U-values, so you can compare directly.
When comparing, remember that a lower U-value is better, just as a higher R-value is better. A common mistake is to think that a U-value of 0.5 is better than 0.3 because 0.5 is larger – but the opposite is true: 0.3 lets less heat through.
Common Mistakes and Misconceptions
- Mixing units: The most common error is using an R-value in metric units with a U-value formula for imperial, or vice versa. Always check the units before calculating.
- Forgetting the reciprocal: U = 1/R, not R = 1/U (though that is also true, but people sometimes forget which is which).
- Confusing R-value with RSI: RSI is the metric R-value (m²·K/W). An R-value of 13 in imperial is about RSI 2.29. The numbers are not interchangeable.
- Assuming U-value is constant: In reality, U-values of building assemblies vary with temperature and wind, but the rated values are for standard conditions.
Practical Applications
Here are a few places where you might need to convert R to U:
- Building energy codes: Some codes specify maximum U-values for windows, while others specify minimum R-values for walls. You may need to check compliance across different sections.
- Product comparison: When buying insulation from an international supplier, the R-value might be listed in metric units. Convert to your local system to compare.
- Heat loss calculations: To calculate heat loss through a wall, you use U-value: Heat loss = U × Area × Temperature difference. If you only have R-values, you need to convert.
- Window replacement: If you are replacing a window, the new window’s U-factor can be converted to an R-value to compare with the old window’s insulation level.
Limits of the Simple Conversion
The U = 1/R relationship is exact for a single homogeneous layer under steady-state conditions. However, real building assemblies are composed of multiple layers, and the total R-value is the sum of the individual R-values. The total U-value is then 1 / (sum of R-values). This works fine for series heat flow (layers stacked), but if there are parallel heat paths (e.g., studs in a wall), the effective U-value is a weighted average, not a simple reciprocal. Also, surface air films contribute to the total R-value; these are often included in published R-values for assemblies. For most practical purposes, the reciprocal conversion is accurate enough.
Frequently Asked Questions
What is the difference between R-value and U-value?
R-value measures thermal resistance – how well a material resists heat flow. U-value measures thermal transmittance – how much heat actually passes through. They are reciprocals: U = 1/R. Higher R is better insulation; lower U is better insulation.
How do I convert R-13 to U-value?
Divide 1 by 13 to get 0.077 BTU/(ft²·°F·h). To get W/(m²·K), multiply that by 5.678263, giving 0.437 W/(m²·K). The calculator above does this automatically.
What is a good U-value for a window?
In the U.S., ENERGY STAR windows in colder climates typically have U-factors of 0.30 or lower. In Europe, modern double-glazed windows often have U-values around 1.0-1.5 W/(m²·K). Lower is better.
Can I convert U-value back to R-value?
Yes, simply take the reciprocal: R = 1/U. For example, a U-value of 0.25 BTU/(ft²·°F·h) corresponds to an R-value of 4.0.
Why do some countries use R and others use U?
It is largely a historical convention. The U.S. and Canada commonly use R-value for insulation and U-factor for windows. Europe, Australia, and most other countries use U-value (often called U-factor) for all building components. The metric system naturally pairs with W/(m²·K).
Does the conversion factor change with temperature?
No. The conversion factor 5.678263 is a fixed unit conversion based on the definitions of BTU, watt, foot, and kelvin. It does not depend on temperature. However, the actual R-value of a material can change with temperature, but that is a separate material property issue.
Related
Formula used
in r | R-value | ft²·°F·h/BTU | 13 | 0.01 | 100 sel sys | Unit system | Imperial (R in ft²·°F·h/BTU)=1, Metric (R in m²·K/W)=2 out u | U-value (imperial) | BTU/(ft²·°F·h) | 1 / r | 4 out um | U-value (metric) | W/(m²·K) | (1 / r) * 5.678263 | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- QPP Calculator Canada: How It Works & How to Use It
- PPP Calculator World Bank: How It Works & How to Use It2,000.00
- PPP Calculator: India vs USA Cost Comparison1,000.00 USD
- PPP Calculator USD to INR: How It Works2,335 INR
- PPP Calculator India vs UK: Real Cost Comparison103.63 GBP
- PPP Calculator India vs Dubai: Real Cost Comparison8,954.58 AED