molecalculator

Moles & Molar Mass

DMF Density vs Pressure Calculator

Calculator No. 01-1740 · Updated · Formula and assumptions shown below

Estimated DMF density 949.15 kg/m3
Density change
5.15 kg/m3
= Estimated DMF density − Reference density
Reference density
944 kg/m3
Set in the form below
Reference pressure
0.101325 MPa
Set in the form below
You enter
Reference density (kg/m3), Reference pressure (MPa), Pressure of interest (MPa), Isothermal compressibility (1/MPa)
You get
Estimated DMF density (kg/m3), Density change (kg/m3)
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator estimates the density of liquid dimethylformamide (DMF) at a specified pressure by applying a liquid-compressibility model. Enter DMF’s reference density, pressure change, and isothermal compressibility; the result is an estimate, not a substitute for measured density or validated property data.

Formula

For a liquid treated as having constant isothermal compressibility over the pressure interval, the estimated density is ρ = ρ₀ × exp[κ × (p − p₀)]. Here, ρ is density at the pressure of interest in kg/m³; ρ₀ is density at the reference pressure in kg/m³; κ is isothermal compressibility in MPa⁻¹; and p and p₀ are the target and reference pressures in MPa. The pressure difference must use the same units as the inverse-pressure unit for κ. The second output is Δρ = ρ − ρ₀, in kg/m³.

This expression follows from κ = (1/ρ)(∂ρ/∂p)T, with κ assumed constant at fixed temperature. It is an approximation because compressibility can change with pressure and temperature. The default compressibility, 0.00055 MPa⁻¹, is a rounded illustrative value for estimating small-to-moderate pressure effects; it is not a guaranteed DMF property for every temperature or pressure. For precision, use a value measured or tabulated for the actual DMF composition, temperature, and pressure range.

Worked Example

Using the calculator defaults: ρ₀ = 944 kg/m³, p₀ = 0.101325 MPa, p = 10 MPa, and κ = 0.00055 MPa⁻¹.

  1. Pressure increase: p − p₀ = 10 − 0.101325 = 9.898675 MPa.
  2. Dimensionless exponent: κ(p − p₀) = 0.00055 × 9.898675 = 0.00544427125.
  3. Density estimate: ρ = 944 × exp(0.00544427125) ≈ 944 × 1.005459 = 949.15 kg/m³, or 949.15 kg/m³ to two decimal places.
  4. Density change: Δρ = 949.15 − 944 ≈ 5.15 kg/m³.

Assumptions

  • DMF is treated as a single liquid phase with unchanged composition.
  • Temperature is fixed; the model does not account for thermal expansion or temperature-dependent compressibility.
  • Compressibility is constant across the pressure interval, and the exponential relation is used as an approximation.
  • The reference density and compressibility must correspond to the relevant grade and temperature. The defaults are illustrative, not universal constants.

What Pressure Does to DMF Density

DMF is the common abbreviation for N,N-dimethylformamide, a polar organic solvent. Like most liquids, it becomes slightly denser when pressure increases: pressure compresses the liquid’s molecular spacing, reducing its volume for a given mass. The effect is usually much smaller than the density changes caused by temperature shifts or by mixing DMF with another substance, but it matters in high-pressure measurements and calculations that require precise fluid properties.

Density is mass divided by volume. If a fixed mass of DMF is compressed into a smaller volume, its density rises. The fractional change depends on compressibility: a less compressible liquid has a smaller density increase for the same pressure rise. In this model, pressure change is entered in MPa and compressibility in inverse MPa, so their product is dimensionless as required by the exponential function.

Pressure must be compared with a reference pressure, not treated as an isolated number. The defaults use a reference near atmospheric pressure, 0.101325 MPa. If a reference density was reported at a different pressure, replace both reference inputs accordingly; otherwise the calculation applies the wrong pressure interval.

How to Use the Estimate

  • Reference density: Enter a density for DMF at a documented temperature and reference pressure. Do not assume the default applies to a mixture, wet solvent, or a different temperature.
  • Reference and target pressures: Enter both in MPa. For example, 1 bar is 0.1 MPa, and 1 atmosphere is 0.101325 MPa. Convert pressure values before entering them if your source uses another unit.
  • Compressibility: Use an isothermal compressibility in MPa⁻¹ measured or reported for suitable conditions. If a source gives Pa⁻¹, convert using 1 MPa = 1,000,000 Pa; a Pa⁻¹ value is multiplied by 1,000,000 to express it in MPa⁻¹.
  • Interpret the output: The first result is estimated density at the target pressure. The second is the change relative to the reference density. A negative pressure change predicts lower density in the model, provided the liquid remains in the relevant range.

For a quick scale check, with κ = 0.00055 MPa⁻¹, a 1 MPa increase produces an estimated fractional density increase of about 0.055% near the reference state. That is a small change, but at 10 MPa it accumulates to roughly half a percent under the constant-compressibility assumption.

Accuracy, Temperature, and Common Mistakes

The calculator does not determine DMF’s exact density from first principles. It propagates a supplied reference density using a simplified pressure correction. Real-property calculations may require an equation of state or tabulated density data validated over the exact temperature and pressure range. The listed defaults make the arithmetic usable but should not be mistaken for certified data.

Temperature is especially important because liquids typically expand when warmed, lowering their density. A pressure-only calculation cannot separate that effect. Use reference density and compressibility measured at the temperature of interest, and do not apply this estimate to a temperature-changing process as if it represented the full density change.

  • Mixing pressure units: Putting a pressure in bar into a field labeled MPa creates a tenfold error. Convert units first.
  • Using gauge pressure as absolute pressure: Pressure-dependent properties are generally referenced to absolute pressure. Ensure the reference and target values use the same pressure convention; a pressure difference is unaffected by adding the same atmospheric offset to both, but inconsistent conventions are not.
  • Using the wrong compressibility: Values vary with temperature, pressure, and material composition. Avoid treating a generic estimate as exact.
  • Overinterpreting decimals: The displayed precision is arithmetic rounding, not a statement of measurement accuracy. Input uncertainty can exceed the last displayed digits.

DMF is a hazardous laboratory solvent. For any bench work, follow your lab method, the safety data sheet (SDS) and your supervisor. The calculator is for property estimation and does not provide handling or process-safety instructions.

Frequently Asked Questions

Does DMF density increase with pressure?
Yes. For liquid DMF at fixed temperature, increasing pressure generally compresses the liquid and increases its density. The size of the change depends on compressibility and the pressure range.

What is the density of DMF at atmospheric pressure?
There is no single value independent of temperature and sample composition. The calculator’s default reference density of 944 kg/m³ is an illustrative input, not a universal specification. Use a reliable value for the temperature and material you are considering.

How much does DMF density change per MPa?
Near a given reference state, the fractional change is approximately κ per MPa for a small pressure increase. With the illustrative κ of 0.00055 MPa⁻¹, that is about 0.055% per MPa; the absolute change also depends on the starting density.

Can I use this for DMF at a different temperature?
Only if you replace the reference density and compressibility with values suitable for that temperature. This calculator holds temperature fixed and does not model thermal expansion.

Is the calculation accurate at very high pressure?
Not necessarily. The constant-compressibility approximation becomes less reliable as pressure moves far from the reference state. For high-pressure engineering or research work, use validated property data or an appropriate equation of state.

Related

Formula used
in rho0 | Reference density | kg/m3 | 944 | 0
in p0 | Reference pressure | MPa | 0.101325 | 0
in p | Pressure of interest | MPa | 10 | 0
in kappa | Isothermal compressibility | 1/MPa | 0.00055 | 0
out rho | Estimated DMF density | kg/m3 | rho0 * exp(kappa * (p - p0)) | 2
out change | Density change | kg/m3 | rho - rho0 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section