The enthalpy change formula at A level is ΔH = q / n, where q is the heat energy absorbed or released (in joules) and n is the number of moles of the substance (usually the limiting reactant). This gives the enthalpy change in joules per mole (J/mol), which is often converted to kilojoules per mole (kJ/mol) by dividing by 1000. This calculator works out ΔH from the mass of a solution, its specific heat capacity, the temperature change, and the moles of the reactant you choose.
Formula
The core relationship is:
q = m × c × ΔT
where:
- q = heat energy absorbed or released (J)
- m = mass of the substance being heated or cooled (g) – usually the mass of the solution
- c = specific heat capacity (J g⁻¹ °C⁻¹) – for water or dilute aqueous solutions, use 4.18 J g⁻¹ °C⁻¹
- ΔT = temperature change in °C (final temperature minus initial temperature)
Then the enthalpy change per mole is:
ΔH = q / n
where n is the number of moles of the substance that is the limiting reactant (the one you are measuring the enthalpy change for). The result is in J/mol; divide by 1000 to get kJ/mol.
In the calculator above, the first output q is the heat energy in joules, and the second output ΔH is the enthalpy change in kJ/mol. The sign of ΔT determines the sign of ΔH: a negative ΔT (cooling) gives a negative ΔH (exothermic), and a positive ΔT (heating) gives a positive ΔH (endothermic).
Worked Example
Using the default values from the calculator:
- Mass of solution, m = 100 g
- Specific heat capacity, c = 4.18 J g⁻¹ °C⁻¹
- Temperature change, ΔT = 12.5 °C
- Moles of reactant, n = 0.050 mol
First, calculate the heat energy q:
q = m × c × ΔT = 100 g × 4.18 J g⁻¹ °C⁻¹ × 12.5 °C = 5225 J
Then convert to kJ: 5225 J = 5.225 kJ
Now divide by the number of moles:
ΔH = q / n = 5.225 kJ / 0.050 mol = 104.5 kJ/mol
The calculator gives 104.50 kJ/mol (rounded to 2 decimal places). The positive sign indicates an endothermic reaction (heat absorbed). If the temperature had dropped by 12.5 °C, the result would be −104.5 kJ/mol, indicating an exothermic reaction.
Assumptions
- The solution has the same specific heat capacity as water (4.18 J g⁻¹ °C⁻¹). This is a good approximation for dilute aqueous solutions.
- The density of the solution is 1 g/mL, so the mass of the solution equals its volume in mL.
- No heat is lost to the surroundings (perfect insulation). In practice, some heat is lost, so experimental values are often lower than theoretical ones.
- The temperature change is measured accurately, and the reaction goes to completion.
- The substance whose enthalpy change you want is the limiting reactant, and you know its moles exactly.
How to Choose the Correct Moles (n)
The most common mistake at A level is using the wrong number of moles. The enthalpy change is always per mole of a specific substance, usually the one you are asked about. For example:
- In a neutralisation reaction (NaOH + HCl → NaCl + H₂O), the enthalpy change of neutralisation is per mole of water formed. If you use 25.0 cm³ of 1.0 mol/dm³ HCl, then moles of HCl = (25.0/1000) × 1.0 = 0.025 mol. Since the reaction is 1:1, this is also the moles of water formed.
- In a combustion reaction, the enthalpy change of combustion is per mole of the fuel burned. If you burn 0.10 g of methanol (Mr = 32.0), moles = 0.10 / 32.0 = 0.003125 mol.
- In a displacement reaction (e.g., zinc with copper sulfate), the enthalpy change is per mole of the metal that reacts or per mole of the solution that changes.
Always read the question carefully: it will specify “per mole of X”. Use that X as your n. If you are not told, use the limiting reactant – the one that is completely used up.
Common Mistakes and How to Avoid Them
- Unit mix-ups: The most frequent error. q is in joules, but ΔH is usually reported in kJ/mol. Always convert q to kJ before dividing by n, or divide by 1000 at the end.
- Using the wrong mass: The mass in q = m c ΔT should be the mass of the solution that absorbs or releases heat, not the mass of the solid reactant. For example, if you add 5 g of ammonium chloride to 100 g of water, the total mass is 105 g, but the heat change is mainly in the 100 g of water. In practice, you use the mass of the solution (water + dissolved solid), which is 105 g. Check your exam board’s convention – many mark schemes use the total mass.
- Forgetting the sign: A temperature rise (ΔT positive) means the reaction released heat, so ΔH is negative (exothermic). A temperature fall (ΔT negative) means heat was absorbed, so ΔH is positive (endothermic). Many students drop the sign.
- Rounding too early: Keep intermediate values to at least 3 significant figures. Round only the final answer.
- Ignoring the specific heat capacity of the calorimeter: At A level, you usually ignore the heat capacity of the container. If the question gives the heat capacity of the calorimeter (in J/°C), you must add that term: q = m c ΔT + C_cal ΔT.
Experimental Methods: Calorimetry
In the lab, you measure the temperature change of a known mass of water (or solution) when a reaction occurs. Two common setups:
- Solution calorimetry: For reactions like neutralisation or displacement. You mix solutions in an insulated cup (polystyrene cup) and record the highest or lowest temperature reached. The mass is the total mass of the mixed solution.
- Flame calorimetry: For combustion reactions. You burn a fuel (e.g., an alcohol) and use the flame to heat a known mass of water in a metal calorimeter. You measure the mass of fuel burned and the temperature rise of the water.
In both cases, you then apply the formula. For flame calorimetry, the mass is the mass of water (not the fuel), and the moles are the moles of fuel burned.
Limitations of the Formula
The simple formula assumes no heat loss, which is never true. In a school lab, heat is lost to the surroundings, so the measured temperature change is smaller than the theoretical value. This makes experimental ΔH values less exothermic (or less endothermic) than the true values. For combustion reactions, heat loss is significant, so experimental values are often much lower than the data book values.
Another limitation is that the specific heat capacity of the solution may not be exactly 4.18 J g⁻¹ °C⁻¹ if the solution is not dilute or if it contains a high concentration of solute. For concentrated solutions, the value can differ by a few percent.
Finally, the formula assumes the reaction goes to completion and that the temperature change is measured at the instant of mixing. In slow reactions, heat is lost while the reaction is still occurring, leading to inaccurate results.
Frequently Asked Questions
What is the difference between ΔH and q?
q is the heat energy transferred in a particular experiment (in joules). ΔH is the enthalpy change per mole of a substance (in kJ/mol). They are related by ΔH = q/n. q depends on how much reactant you used; ΔH is an intensive property that is characteristic of the reaction.
Why is the specific heat capacity of water 4.18?
4.18 J g⁻¹ °C⁻¹ is the amount of energy needed to raise the temperature of 1 gram of water by 1 °C. It is a measured physical constant. For dilute aqueous solutions, it is a good approximation because the solution is mostly water.
Do I need to convert cm³ to dm³?
Yes, for concentration calculations. Concentration in mol/dm³ means moles per cubic decimetre (1 dm³ = 1000 cm³). So to find moles from a volume in cm³, divide by 1000. For example, 25.0 cm³ = 0.0250 dm³. But for the mass in the heat formula, you can use grams directly – just remember that 1 cm³ of water has a mass of 1 g.
How do I know if ΔH is positive or negative?
If the temperature of the surroundings (the solution) increases, the reaction is exothermic and ΔH is negative. If the temperature decreases, the reaction is endothermic and ΔH is positive. In the formula, the sign comes from ΔT: ΔT = T_final − T_initial. A positive ΔT gives a positive q, but for an exothermic reaction the system loses heat, so by convention ΔH is negative. In the calculator, we simply use the sign of ΔT as you enter it – if you enter a temperature rise as positive, you get a positive ΔH, which would be incorrect for an exothermic reaction. So always enter ΔT as negative for exothermic (cooling) and positive for endothermic (heating). In practice, you should assign the sign based on the observed temperature change.
What if the question gives the heat capacity of the calorimeter?
Then you must add the heat absorbed by the calorimeter itself: q = (m × c × ΔT) + (C_cal × ΔT), where C_cal is the heat capacity of the calorimeter in J/°C. This gives a more accurate value of q.
Why is my experimental value different from the data book value?
Heat loss to the surroundings is the main reason. Also, incomplete combustion (for fuels), evaporation of water, and the specific heat capacity of the solution not being exactly 4.18 all contribute. These are systematic errors that make the measured temperature change smaller than ideal.