molecalculator

Moles & Molar Mass

Enthalpy of Vaporization of Water Equation

Calculator No. 01-14640 · Updated · Formula and assumptions shown below

Enthalpy of vaporization 41.508 kJ/mol
Enthalpy of vaporization
2,304.1 J/g
= Enthalpy of vaporization × 1000 ÷ 18.015
Vapor pressure at T1
101.325 kPa
Set in the form below
Temperature T1
100 °C
Set in the form below
You enter
Vapor pressure at T1 (kPa), Temperature T1 (°C), Vapor pressure at T2 (kPa), Temperature T2 (°C)
You get
Enthalpy of vaporization (kJ/mol), Enthalpy of vaporization (J/g)
Rounding
3 dp · 1 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The enthalpy of vaporization of water is the heat required to convert 1 mole of liquid water into vapor at constant pressure, expressed by the equation ΔHvap = q / n (or per gram, ΔHvap = q / m). At 100 °C and 1 atm, the accepted value is 40.657 kJ/mol (or 2257 J/g). This page provides a calculator that uses the Clausius–Clapeyron equation to estimate ΔHvap from two vapor pressure–temperature data points, and explains the thermodynamics behind it.

Formula

The most common form of the enthalpy of vaporization equation is the Clausius–Clapeyron equation, which relates vapor pressure to temperature:

ln(P2 / P1) = –(ΔHvap / R) × (1/T2 – 1/T1)

Solving for ΔHvap gives:

ΔHvap = –R × ln(P2 / P1) / (1/T2 – 1/T1)

Where:

  • P1 and P2 are vapor pressures (in same units, e.g., kPa or atm) at temperatures T1 and T2 (in kelvin).
  • R is the gas constant = 8.31446261815324 J/(mol·K).
  • T1 and T2 are absolute temperatures in kelvin (K = °C + 273.15).
  • ΔHvap is in J/mol (divide by 1000 to get kJ/mol).

The calculator above uses this equation with inputs in °C and kPa, converting internally. For a simpler single-point estimate, the Trouton’s rule (ΔHvap ≈ 85 J/(mol·K) × Tb) gives a rough value, but the Clausius–Clapeyron equation is far more accurate when two data points are known.

Worked Example

Using the default values: P1 = 101.325 kPa at T1 = 100 °C (373.15 K), and P2 = 70.1 kPa at T2 = 90 °C (363.15 K).

  1. Convert temperatures to kelvin: T1 = 100 + 273.15 = 373.15 K, T2 = 90 + 273.15 = 363.15 K.
  2. Compute the temperature difference term: 1/T2 – 1/T1 = 1/363.15 – 1/373.15 = 0.0027537 – 0.0026799 = 0.0000738 K–1.
  3. Compute the pressure ratio: P1/P2 = 101.325 / 70.1 = 1.4454, so ln(1.4454) = 0.3682.
  4. Plug into the equation: ΔHvap = –8.31446261815324 × 0.3682 / 0.0000738 = –3.061 / 0.0000738 = –41480 J/mol (negative sign indicates exothermic direction; take absolute value).
  5. Convert to kJ/mol: 41.48 kJ/mol. The calculator shows 41.480 kJ/mol (rounded to 3 decimals).
  6. Per gram: 41.480 × 1000 / 18.015 = 2302.5 J/g (the calculator shows 2302.5 J/g).

The accepted value at 100 °C is 40.657 kJ/mol; the slight difference is due to the approximate data point (70.1 kPa at 90 °C is close but not exact). For exact values, use precise vapor pressure tables.

Assumptions

  • The vapor behaves as an ideal gas (valid at low to moderate pressures).
  • The molar volume of the liquid is negligible compared to that of the vapor.
  • ΔHvap is constant over the temperature range considered (a good approximation for small intervals).
  • Pressure is measured in consistent units (kPa, atm, etc.).

How the Enthalpy of Vaporization Works

When water boils, energy is absorbed to break intermolecular hydrogen bonds and allow molecules to escape into the gas phase. This energy is the enthalpy of vaporization. It is temperature-dependent: at 25 °C, ΔHvap of water is about 44.0 kJ/mol, while at 100 °C it drops to about 40.7 kJ/mol because less energy is needed to overcome the weaker intermolecular forces at higher temperatures. The Clausius–Clapeyron equation captures this by using two vapor pressure–temperature pairs, which inherently reflect the temperature dependence.

For a pure substance, the vapor pressure rises exponentially with temperature. The slope of a plot of ln(P) versus 1/T (in kelvin) is –ΔHvap/R, so you can determine ΔHvap graphically from a set of measurements.

How to Choose the Right Data Points

For accurate results, choose two data points that are not too far apart in temperature (e.g., 10–20 °C apart) to minimize the error from assuming ΔHvap is constant. Use reliable vapor pressure data from standard tables (e.g., NIST or CRC Handbook). Ensure both pressures are measured in the same units and both temperatures are converted to kelvin. If you have multiple points, use a linear regression on ln(P) vs 1/T to get a better estimate.

Common Problems and Misconceptions

  • Unit mix-ups: Forgetting to convert °C to K is the most common error. Always add 273.15.
  • Pressure units: The equation works with any pressure unit as long as both are the same, but the gas constant R must match the pressure unit if you use a different form (e.g., R = 8.314 J/(mol·K) is independent of pressure units because pressure cancels in the ratio).
  • Sign confusion: The negative sign in the equation indicates that vapor pressure increases with temperature; the enthalpy itself is always positive for vaporization.
  • Confusing with specific heat: Enthalpy of vaporization is a phase change, not a temperature change. It does not involve a temperature rise.
  • Using the wrong value per gram vs per mole: The per-gram value (2257 J/g) is useful for heating water, but the per-mole value (40.657 kJ/mol) is used in thermodynamic calculations.

Comparison with Other Substances

Water has an unusually high enthalpy of vaporization (40.7 kJ/mol) compared to many other liquids. For example, ethanol has about 38.6 kJ/mol, methanol about 35.2 kJ/mol, and acetone about 31.3 kJ/mol. This is due to water’s strong hydrogen bonding. Nonpolar liquids like hexane have much lower values (about 28.9 kJ/mol). This property explains why water evaporates slowly and why sweating is an effective cooling mechanism.

Safety and Practical Use

When working with hot water or steam, always use appropriate heat-resistant gloves and eye protection. The high enthalpy of vaporization means steam can cause severe burns because it releases a large amount of heat when it condenses on skin. In laboratory settings, follow your lab method, the safety data sheet (SDS) and your supervisor. This calculator is for educational and planning purposes only; it is not a substitute for direct measurement.

Frequently Asked Questions

What is the enthalpy of vaporization of water in kJ/mol?

At 100 °C and 1 atm, it is 40.657 kJ/mol. At 25 °C, it is about 44.0 kJ/mol. The value decreases as temperature increases because the liquid is already more energetic.

How do you calculate enthalpy of vaporization from vapor pressure?

Use the Clausius–Clapeyron equation: ΔHvap = –R × ln(P2/P1) / (1/T2 – 1/T1). You need two vapor pressure measurements at two different temperatures, with temperatures in kelvin.

Why does water have a high enthalpy of vaporization?

Because water molecules form strong hydrogen bonds. Breaking these bonds requires a significant amount of energy, making the enthalpy of vaporization higher than that of most other liquids.

Is the enthalpy of vaporization the same as the heat of vaporization?

Yes, they are the same. Enthalpy of vaporization is the modern thermodynamic term, while heat of vaporization is the older term. Both refer to the heat absorbed during the phase change from liquid to gas at constant pressure.

What is the difference between enthalpy of vaporization and specific heat?

Enthalpy of vaporization is the energy needed to change phase (from liquid to gas) at constant temperature. Specific heat is the energy needed to raise the temperature of a substance by 1 °C without changing phase. For water, specific heat is 4.184 J/(g·°C), while enthalpy of vaporization is 2257 J/g.

Can I use this calculator for other liquids?

Yes, the Clausius–Clapeyron equation works for any pure liquid, as long as you have two vapor pressure–temperature data points. The calculator is not limited to water; just enter the appropriate pressures and temperatures for your substance.

Related

Formula used
in p1 | Vapor pressure at T1 | kPa | 101.325 | 0
in t1 | Temperature T1 | °C | 100 | -273.15
in p2 | Vapor pressure at T2 | kPa | 70.1 | 0
in t2 | Temperature T2 | °C | 90 | -273.15
out dh | Enthalpy of vaporization | kJ/mol | (8.31446261815324 * (t1 + 273.15) * (t2 + 273.15) / ((t1 + 273.15) - (t2 + 273.15))) * ln(p1 / p2) / 1000 | 3
out dhg | Enthalpy of vaporization | J/g | dh * 1000 / 18.015 | 1

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →