molecalculator

Moles & Molar Mass

Water Enthalpy of Vaporization (kJ/kg) & Calculator

Calculator No. 01-14630 · Updated · Formula and assumptions shown below

Enthalpy of vaporization 2,257 kJ/kg
Total heat to vaporize 1 kg
2,257 kJ
= Enthalpy of vaporization
Temperature
100 °C
Set in the form below
Pressure
101.325 kPa
Set in the form below
You enter
Temperature (°C), Pressure (kPa)
You get
Enthalpy of vaporization (kJ/kg), Total heat to vaporize 1 kg (kJ)
Rounding
0 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The enthalpy of vaporization of water is 2257 kJ/kg at 100°C and 1 atm pressure. This means that turning 1 kilogram of boiling water into steam requires 2257 kilojoules of energy input. Below is a calculator that converts this value for different temperatures and pressures, along with the full explanation of how it works.

Formula

The enthalpy of vaporization (ΔHvap) is the heat required to change 1 kg of a liquid into vapor at constant temperature and pressure. For water, the standard value is 2257 kJ/kg at 100°C and 101.325 kPa (1 atm).

For temperatures between 0°C and 374°C (the critical temperature), a linear approximation works well for most lab calculations:

ΔHvap ≈ 2257 − 2.1 × (T − 100) + 0.0005 × (T − 100)²

Where:

  • ΔHvap = enthalpy of vaporization in kJ/kg
  • T = temperature in °C
  • 2257 = reference value at 100°C (kJ/kg)
  • −2.1 = approximate slope (kJ/kg per °C) near 100°C
  • 0.0005 = curvature correction term (kJ/kg per °C²)

This formula is a practical fit, not an exact physical law. For precise engineering work, use steam tables or the IAPWS-IF97 standard, but for routine chemistry and lab estimates, this approximation is within a few percent.

Worked Example

Using the default values from the calculator (T = 100°C, P = 101.325 kPa):

ΔHvap = 2257 − 2.1 × (100 − 100) + 0.0005 × (100 − 100)²

= 2257 − 0 + 0 = 2257 kJ/kg

At 150°C (typical for pressurized steam systems):

ΔHvap = 2257 − 2.1 × (50) + 0.0005 × (50)²

= 2257 − 105 + 1.25 = 2153.25 kJ/kg

So heating water to a higher temperature before vaporization lowers the extra heat needed for the phase change, because the molecules are already more energetic.

Assumptions

  • Water is pure and degassed (no dissolved salts or gases).
  • The system is at equilibrium (liquid and vapor coexist).
  • The formula is valid for 0–374°C, but accuracy decreases near the critical point.
  • Pressure is assumed to be the saturation pressure corresponding to the temperature; if you enter a different pressure, the calculator ignores it for the enthalpy estimate (the formula is temperature-based).

Why the Value Changes with Temperature

At 100°C, water molecules are already moving fast, but they still need a large energy boost to break all hydrogen bonds and escape into the gas phase. As temperature increases, the average kinetic energy of molecules rises, so the additional energy needed to overcome intermolecular forces decreases. At the critical point (374°C, 22.064 MPa), the enthalpy of vaporization drops to zero because liquid and vapor become indistinguishable.

This is why steam at higher pressure (and therefore higher temperature) contains less latent heat per kilogram than steam at 100°C. For example, at 200°C (about 1.55 MPa), ΔHvap is roughly 1930 kJ/kg.

Common Mistakes and Misconceptions

  • Confusing kJ/kg with kJ/mol: The molar enthalpy of vaporization of water is about 40.65 kJ/mol at 100°C. To convert: 2257 kJ/kg ÷ 18.015 g/mol × 1000 g/kg = 40.65 kJ/mol.
  • Using the value for ice or steam: The enthalpy of vaporization applies only to the liquid-to-gas transition. Melting ice requires 334 kJ/kg (enthalpy of fusion), and heating steam requires specific heat capacity (about 2.0 kJ/kg·K).
  • Assuming it’s constant: Many textbooks quote 2257 kJ/kg as a constant, but it varies by several percent over the range of typical lab temperatures (0–100°C). At 0°C, the value is about 2500 kJ/kg.
  • Ignoring pressure: At lower pressures (e.g., vacuum), water boils at lower temperatures, so the enthalpy of vaporization is higher. At 50°C and 12.35 kPa, it’s about 2383 kJ/kg.

How to Use the Calculator

Enter the temperature of the water in °C. The calculator gives the enthalpy of vaporization in kJ/kg. For a quick estimate of total energy to boil a given mass, multiply the result by the mass in kg. For example, to boil 2 kg of water at 100°C: 2 × 2257 = 4514 kJ.

If you are working with a pressure cooker or autoclave, enter the actual operating temperature (e.g., 121°C for typical autoclaving). The calculator will give a slightly lower value than at 100°C, which is why autoclaves require less latent heat per kg but still use more total energy because of the higher temperature.

Real-World Applications

  • Steam turbines: Power plants use the high enthalpy of vaporization to drive turbines; the latent heat is released when steam condenses.
  • Distillation: In a simple distillation, you must supply enough heat to vaporize the liquid; knowing ΔHvap helps size the heating mantle.
  • Cooling systems: Evaporative coolers rely on the high latent heat to absorb energy from the air.
  • Safety: Burns from steam are more severe than from boiling water because steam releases its latent heat (2257 kJ/kg) upon condensing on skin, in addition to the sensible heat.

Frequently Asked Questions

Why is the enthalpy of vaporization of water so high?

Water molecules form strong hydrogen bonds (about 20 kJ/mol each). Breaking these bonds requires a lot of energy, which is why water has one of the highest enthalpies of vaporization among common liquids. For comparison, ethanol is about 841 kJ/kg, and acetone is about 500 kJ/kg.

Does the enthalpy of vaporization change with altitude?

Yes, indirectly. At higher altitudes, atmospheric pressure is lower, so water boils at a lower temperature. At 2000 m elevation, water boils at about 93°C, and the enthalpy of vaporization is about 2290 kJ/kg—slightly higher than at sea level because the temperature is lower.

How do I convert kJ/kg to J/mol?

Multiply by the molar mass of water (18.015 g/mol) and divide by 1000 to get kJ/mol, or multiply by 1000 to get J/g and then by 18.015 to get J/mol. Example: 2257 kJ/kg × (18.015 g/mol) / 1000 = 40.65 kJ/mol.

Is the enthalpy of vaporization the same as latent heat?

Yes, they are the same thing.

Related

Formula used
in t | Temperature | °C | 100 | 0 | 374
in p | Pressure | kPa | 101.325 | 0 | 22064
out hvap | Enthalpy of vaporization | kJ/kg | 2257 - 2.1 * (t - 100) + 0.0005 * (t - 100)^2 | 0
out htot | Total heat to vaporize 1 kg | kJ | hvap | 0

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →