molecalculator

Moles & Molar Mass

Water Enthalpy of Vaporization: Value & Uses

Calculator No. 01-14634 · Updated · Formula and assumptions shown below

Heat required 40.70 kJ
Heat per gram
2.259 kJ/g
= 40.7 ÷ 18.015
Mass of water
18.015 g
Set in the form below
Temperature
100 °C
Set in the form below
You enter
Mass of water (g), Temperature (°C), Pressure (atm)
You get
Heat required (kJ), Heat per gram (kJ/g)
Rounding
2 dp · 3 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The enthalpy of vaporization of water is 40.7 kJ/mol (or 2.26 kJ/g) at its normal boiling point of 100°C and 1 atm pressure. This is the energy required to convert one mole of liquid water at 100°C into one mole of water vapor at the same temperature and pressure.

Formula

The enthalpy of vaporization (ΔHvap) is the heat absorbed when a substance changes from liquid to gas at constant pressure. For water, the standard value at 100°C and 1 atm is:

ΔHvap = 40.7 kJ/mol

To calculate the heat required for a given mass of water:

q = m × (ΔHvap / M)

where:

  • q = heat required (kJ)
  • m = mass of water (g)
  • ΔHvap = 40.7 kJ/mol (at 100°C, 1 atm)
  • M = molar mass of water = 18.015 g/mol

The calculator above uses this formula. You enter the mass of water, temperature, and pressure (the latter two are for reference; the calculator assumes the standard value at 100°C and 1 atm). The result is the heat needed to vaporize that mass completely.

Worked Example

Using the default values: m = 18.015 g (exactly one mole of water), T = 100°C, P = 1 atm.

Step 1: Identify the molar enthalpy of vaporization: ΔHvap = 40.7 kJ/mol.

Step 2: Convert mass to moles (if needed): n = m / M = 18.015 g / 18.015 g/mol = 1.0000 mol.

Step 3: Calculate heat: q = n × ΔHvap = 1.0000 mol × 40.7 kJ/mol = 40.7 kJ.

Step 4: The calculator also shows heat per gram: 40.7 kJ / 18.015 g = 2.259 kJ/g ≈ 2.26 kJ/g.

So vaporizing 18.015 g (one mole) of water at 100°C requires 40.7 kJ of energy.

Assumptions

  • Water is pure and at its normal boiling point (100°C) under 1 atm pressure.
  • The value 40.7 kJ/mol is the enthalpy of vaporization at 100°C; at other temperatures, the value changes slightly (see below).
  • The process is at constant pressure, so the heat equals the enthalpy change.
  • The calculator does not account for the heat needed to raise the water temperature from ambient to 100°C; that is separate.

Why the Value Changes with Temperature

The enthalpy of vaporization is not a fixed constant; it depends on temperature. At 25°C, the enthalpy of vaporization of water is about 44.0 kJ/mol. At 100°C, it drops to 40.7 kJ/mol. Why? Because at higher temperatures, the liquid molecules already have more kinetic energy, so less additional energy is needed to overcome intermolecular forces and escape into the gas phase. Near the critical point (374°C), the enthalpy of vaporization approaches zero, because the liquid and vapor phases become indistinguishable.

This temperature dependence matters in real-world calculations. For example, if you are boiling water at sea level (100°C), use 40.7 kJ/mol. If you are estimating evaporation at room temperature, use ~44 kJ/mol for a rough figure. For precise work, look up a table of ΔHvap at the specific temperature.

Common Mistakes and Misconceptions

  • Confusing enthalpy of vaporization with specific heat: Specific heat (4.18 J/g·°C) heats water without changing phase; enthalpy of vaporization changes phase without changing temperature. They are different.
  • Using kJ/mol vs. kJ/g: The value 40.7 kJ/mol is per mole; 2.26 kJ/g is per gram. Mixing them up leads to errors by a factor of 18.
  • Forgetting to account for heating the water to 100°C: To boil water from room temperature, you first need to heat it to 100°C (q = m·c·ΔT), then add the vaporization heat. The calculator only gives the vaporization part.
  • Assuming the value is the same at all pressures: At higher altitudes, water boils at a lower temperature (e.g., ~95°C at 2000 m), and the enthalpy of vaporization is slightly higher (about 41 kJ/mol at 95°C). The difference is small for most purposes.

Real-World Applications

The enthalpy of vaporization of water is central to many processes:

  • Steam power generation: Power plants burn fuel to boil water into steam; the energy required to vaporize water is a major part of the heat input.
  • Cooling systems: Evaporative coolers and sweat rely on the high enthalpy of vaporization to absorb heat from the environment.
  • Distillation: In chemistry labs, distilling water requires supplying the heat of vaporization to each mole of water collected.
  • Food processing: Drying and concentrating foods (e.g., making powdered milk) involves evaporating large amounts of water, and the energy cost is directly related to ΔHvap.
  • Climate and weather: The energy absorbed when ocean water evaporates drives hurricanes and the water cycle.

For example, to vaporize 1 liter (1000 g) of water at 100°C, you need:

q = 1000 g × (40.7 kJ / 18.015 g) = 2259 kJ ≈ 2.26 MJ.

That’s about 0.63 kWh of energy—enough to run a typical microwave for about an hour.

How to Measure It Experimentally

In a lab, the enthalpy of vaporization is often measured using a calorimeter. A known mass of water is boiled, and the steam is condensed in a cold water bath. The heat released by condensation (which equals the heat of vaporization) is absorbed by the water in the calorimeter. By measuring the temperature rise of the calorimeter water, you can calculate the heat absorbed, then divide by the mass of condensed steam to get the enthalpy of vaporization per gram.

Another method uses the Clausius–Clapeyron equation, which relates vapor pressure to temperature. By measuring vapor pressure at several temperatures and plotting ln(P) vs. 1/T, the slope gives −ΔHvap/R, where R = 8.314 J/(mol·K). This method works for any temperature range and is commonly used in physical chemistry labs.

When doing such experiments, always follow your lab method, the safety data sheet (SDS) and your supervisor.

Safety and Practical Notes

Boiling water and handling steam involve thermal hazards. Always use appropriate heat-resistant containers and avoid direct contact with steam, which can cause severe burns. When measuring the enthalpy of vaporization in a lab, ensure proper ventilation and use a fume hood if needed. The calculator here is for educational and planning purposes only; it does not replace safe laboratory practice.

Frequently Asked Questions

Why is water’s enthalpy of vaporization so high?

Water has a high enthalpy of vaporization (about 40.7 kJ/mol) because of strong hydrogen bonding between molecules. Breaking these bonds requires a lot of energy compared to other liquids like ethanol (38.6 kJ/mol) or acetone (29.1 kJ/mol). This high value is why sweating cools us effectively and why water is used as a coolant.

Does the enthalpy of vaporization change with altitude?

Yes, indirectly. At higher altitude, the boiling point of water is lower (e.g., ~95°C at 2000 m), and the enthalpy of vaporization at that lower temperature is slightly higher (about 41 kJ/mol at 95°C). The difference is small (about 1–2%), so for most calculations, 40.7 kJ/mol is a good approximation.

How much energy does it take to boil 1 liter of water from 25°C?

First, heat the water from 25°C to 100°C: q1 = 1000 g × 4.18 J/g·°C × 75°C = 313,500 J = 313.5 kJ. Then vaporize at 100°C: q2 = 1000 g × 2.26 kJ/g = 2260 kJ. Total = 313.5 + 2260 = 2573.5 kJ ≈ 2.57 MJ. The vaporization step dominates.

What is the difference between enthalpy of vaporization and heat of evaporation?

They are essentially the same. “Heat of evaporation” is an older term for the enthalpy of vaporization. In thermodynamics, enthalpy (H) is used because the process occurs at constant pressure, and the heat absorbed equals the change in enthalpy (ΔH).

Can I use this calculator for other liquids?

No, this calculator is specific to water. Other liquids have different molar masses and different enthalpies of vaporization. For example, ethanol has ΔHvap = 38.6 kJ/mol and molar mass 46.07 g/mol, so the heat per gram is 0.838 kJ/g, much lower than water’s 2.26 kJ/g.

Why is the enthalpy of vaporization at 25°C different from at 100°C?

At 25°C, water molecules are less energetic, so more energy is needed to break the hydrogen bonds and escape into the gas phase. As temperature increases, the average kinetic energy of molecules increases, so the additional energy needed for vaporization decreases. The value at 25°C is about 44.0 kJ/mol, while at 100°C it is 40.7 kJ/mol.

Related

Formula used
in m | Mass of water | g | 18.015 | 0
in t | Temperature | °C | 100 | 0.01
in p | Pressure | atm | 1 | 0.01
out q | Heat required | kJ | m * (40.7 / 18.015) | 2
out qg | Heat per gram | kJ/g | 40.7 / 18.015 | 3

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →