First-Order Rate Constant: Formula and Example

Calculator No. 08-0806 · Updated · Formula and assumptions shown below

First-order rate constant k 0.0116 s^-1
Fraction of A remaining
0.5000
= Concentration of A at time t ÷ Initial concentration of A
Initial concentration of A
1 mol/L
Set in the form below
Concentration of A at time t
0.5 mol/L
Set in the form below
You enter
Initial concentration of A (mol/L), Concentration of A at time t (mol/L), Elapsed time (s)
You get
First-order rate constant k (s^-1), Fraction of A remaining
Rounding
4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The first-order rate constant is calculated from k = ln([A]0/[A]t)/t, where [A]0 is the initial reactant concentration and [A]t is its concentration after time t. This calculator uses those values to return k in the inverse of the time unit you enter, along with the reactant’s remaining fraction.

Formula

For a reaction that is first order in reactant A, the integrated rate law is ln([A]t) = ln([A]0) − kt. Rearranging gives k = ln([A]0/[A]t)/t. The equivalent common-log form is k = 2.303 log10([A]0/[A]t)/t.

  • k is the first-order rate constant, in inverse time, such as s−1 when t is in seconds.
  • [A]0 is the initial concentration of A, in mol/L in this calculator.
  • [A]t is A’s concentration after elapsed time t, in the same concentration unit.
  • t is the elapsed time, in seconds here. If time is entered in minutes, the result is min−1 instead.

The concentration ratio has no units, so the logarithm is dimensionless. The rate constant’s unit comes from dividing by time. Because the logarithm uses a ratio, the two concentration values must use matching units; they do not have to be mol/L if both are expressed consistently.

Worked Example

Using the calculator’s default values, [A]0 = 1 mol/L, [A]t = 0.5 mol/L, and t = 60 s:

  1. Find the concentration ratio: [A]0/[A]t = 1/0.5 = 2.
  2. Take the natural logarithm: ln(2) = 0.6931471806.
  3. Divide by elapsed time: k = 0.6931471806/60 s = 0.01155245301 s−1, which rounds to 0.0116 s−1 at four decimal places.
  4. Calculate the remaining fraction: [A]t/[A]0 = 0.5/1 = 0.5000, or 50.00% remaining.

Assumptions

  • The measured concentration decreases according to a single first-order rate law over the stated interval.
  • Both concentration measurements refer to the same reactant and use the same units; elapsed time is positive.
  • The rate constant is treated as constant during the interval. Changes in temperature or other reaction conditions can change its value.

What First-Order Means

A first-order reaction has a rate proportional to the concentration of A: rate = −d[A]/dt = k[A], for a reaction whose rate law is first order in A. The minus sign indicates that A is consumed. If the concentration is doubled while conditions remain the same, the instantaneous disappearance rate doubles. The integrated equation describes how concentration changes over a measured period, making it useful when you know concentrations at two times.

Reaction order is determined from experimental behavior or a justified mechanism; it cannot be inferred just from the balanced chemical equation in general. A reaction can also be first order in one reactant but depend on other reactants as well. In that case, the observed or pseudo-first-order constant may apply only while the other reactant concentrations are effectively constant.

How to Use and Interpret k

Enter the initial concentration, the concentration measured later, and the time between those measurements. The later concentration must be positive and lower than the initial concentration for a positive k under a consumption model. The calculator returns a numerical value and units based on seconds, plus the fraction remaining. A fraction of 0.5 means half the initial amount remains; it does not mean the rate constant is 0.5.

The rate constant is not the same as the reaction rate. The rate has concentration-per-time units and depends on concentration, while k has inverse-time units for a first-order law. For example, at a particular concentration, the disappearance rate is k[A]. A larger k means faster decay under the conditions represented, but values should only be compared when the reaction conditions and time units are compatible.

Half-Life and Useful Comparisons

For a first-order process, the half-life is the time required for concentration to fall to half its starting value. Setting [A]t/[A]0 = 1/2 in the integrated law gives t1/2 = ln(2)/k. It does not depend on the starting concentration, provided the same first-order model and conditions apply. With the example k = 0.01155245301 s−1, the half-life is approximately 60.000 s, consistent with the default values.

After each half-life, half of what remains is consumed: after two half-lives, one-quarter remains; after three, one-eighth remains. This differs from a zero-order process, whose concentration falls by a fixed amount per unit time, and a second-order process, whose integrated concentration relationship is different. A straight line in a plot of ln([A]) against time supports a first-order model; its slope is −k.

Common Errors and Limits

  • Reversing the ratio: use [A]0/[A]t. Reversing it changes the sign of the logarithm.
  • Mixing time units: a value calculated using minutes is in min−1, not s−1. Convert time before comparing constants.
  • Using inconsistent concentration units: convert both values to a common unit. The ratio then has no units.
  • Taking log base 10 without the factor: use ln directly, or multiply log10 by 2.303.
  • Overinterpreting rounded data: rounding measured concentrations can noticeably affect the logarithm, especially when the two values are close. Keep precision through intermediate calculations and report only precision justified by the measurements.

This two-point calculation produces a k value only if a first-order model is appropriate. Measurement noise, multiple reaction pathways, changing conditions, or concentrations near a detection limit can make a two-point estimate unreliable. For stronger evidence, calculate ln([A]) for multiple time points and inspect whether it follows a straight line; regression uses all points and can reveal deviations that two measurements conceal. If A increases, either the process is not a simple consumption case, the labels or measurements need checking, or the chosen model may not apply.

Frequently Asked Questions

What is the formula for a first-order rate constant?
Use k = ln([A]0/[A]t)/t. The concentration values must use the same units, and the unit of k is the inverse of the time unit.

What are the units of a first-order rate constant?
They are reciprocal time: s−1 for time in seconds, min−1 for time in minutes, or another corresponding inverse-time unit.

How do I calculate k from a half-life?
For a first-order reaction, k = ln(2)/t1/2. Use the same time unit for the half-life and the resulting inverse-time unit for k.

Can I use log instead of ln?
Yes. With common logarithms, use k = 2.303 log10([A]0/[A]t)/t. Omitting 2.303 gives an incorrect value.

Does a first-order reaction have a constant rate?
No. Its rate constant k is constant only while conditions remain fixed, but the reaction rate k[A] falls as the reactant concentration falls.

Related

Formula used
in a0 | Initial concentration of A | mol/L | 1 | 0.000001
in at | Concentration of A at time t | mol/L | 0.5 | 0.000001
in t | Elapsed time | s | 60 | 0.000001
out k | First-order rate constant k | s^-1 | ln(a0 / at) / t | 4
out f | Fraction of A remaining | - | at / a0 | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section