This calculator works out the half-life timeline for a decaying quantity: you enter the initial amount, the decay constant or half-life, and the elapsed time, and it returns the remaining amount and the fraction left. Use it to see how much of a radioactive isotope or a first-order reactant remains after any number of half-lives.
Formula
The core equation for exponential decay is:
N(t) = N₀ × (1/2)^(t / t½)
- N(t) – amount remaining after time t (same unit as N₀, e.g., grams, moles, becquerels)
- N₀ – initial amount at time zero
- t – elapsed time (any time unit, as long as it matches t½)
- t½ – half-life (same time unit as t)
The exponent t / t½ is the number of half-lives that have passed. For example, after 3 half-lives, the fraction left is (1/2)³ = 1/8 = 0.125.
If you only know the decay constant λ (in reciprocal time, e.g., s⁻¹), use the equivalent form:
N(t) = N₀ × e^(−λt)
where λ = ln(2) / t½. The two formulas give identical results.
Worked Example
Suppose you start with 100 g of a radioactive isotope with a half-life of 6 hours, and you want to know how much remains after 18 hours.
- Calculate the number of half-lives: t / t½ = 18 h / 6 h = 3.
- Compute the fraction remaining: (1/2)³ = 0.125.
- Multiply by the initial amount: 100 g × 0.125 = 12.5 g.
The calculator gives the same result: after 18 hours, 12.5 g remains (fraction = 0.125, number of half-lives = 3).
Assumptions
- First-order kinetics: the decay rate is proportional to the amount present.
- The half-life is constant over time (no changing conditions like temperature or pressure).
- No new material is added or removed during the decay.
Background: What Is a Half-Life?
A half-life is the time required for half of a given quantity to undergo decay (or reaction). It is a fixed property for a given radioactive isotope or a first-order chemical reaction. For example, carbon-14 has a half-life of about 5,730 years, while iodine-131 has a half-life of about 8 days. The concept applies not only to nuclear decay but also to drug elimination from the body, chemical reactions, and even the discharge of capacitors.
The term “half-life” is often confused with “half-time” (used in sports) or “half-life” in gaming, but in science it always refers to exponential decay. The timeline is not linear: after one half-life you have 50%, after two you have 25%, after three 12.5%, and so on. After 10 half-lives, less than 0.1% of the original remains.
How to Use the Calculator
Enter the initial amount (any unit you like, as long as you are consistent), the half-life (in hours, minutes, days, etc.), and the elapsed time (in the same unit as the half-life). The calculator returns the remaining amount and the fraction left. You can also use it in reverse: if you know the remaining amount and want the time, you can rearrange the formula to solve for t:
t = t½ × log₂(N₀ / N(t))
For example, if you start with 80 g and want to know when only 10 g remains, with a half-life of 4 hours: log₂(80/10) = log₂(8) = 3, so t = 4 h × 3 = 12 h.
Common Mistakes and Misconceptions
- Unit mismatch: The most common error is using different time units for half-life and elapsed time. Always convert to the same unit first (e.g., days to hours).
- Confusing half-life with decay constant: λ = ln(2)/t½, not 1/t½. The decay constant is the probability of decay per unit time, not the reciprocal of the half-life.
- Assuming linear decay: After two half-lives, you do not have zero left; you have 25% remaining.
- Rounding too early: If you round the fraction to 0.33 instead of 0.3333, the final amount can be off by several percent.
Real-World Applications
Half-life calculations appear in many fields:
- Radiometric dating: Carbon-14 dating uses the half-life of ¹⁴C (5,730 years) to estimate the age of organic materials.
- Nuclear medicine: Iodine-131 (half-life 8 days) is used for thyroid treatment; the timeline helps plan doses and patient isolation.
- Pharmacokinetics: Drug half-life determines dosing intervals. For example, a drug with a half-life of 4 hours will be roughly 94% eliminated after 16 hours (4 half-lives).
- Environmental science: The half-life of pollutants (e.g., DDT in soil) helps predict how long contamination persists.
In each case, the same mathematical model applies, even though the underlying physical or chemical process differs.
Limitations of the Formula
The simple exponential decay formula assumes first-order kinetics and a constant half-life. In real systems, conditions can change:
- Temperature changes can alter reaction rates for chemical reactions (but not for nuclear decay).
- Biological half-lives are often effective half-lives that combine radioactive decay with excretion or metabolism; they may not be constant if organ function changes.
- Multi-compartment models (e.g., in pharmacokinetics) may show a “distribution phase” that is not a simple single half-life.
For nuclear decay, the half-life is essentially constant under normal conditions, but for chemical reactions, you must ensure the reaction is truly first-order and that no side reactions occur.
Frequently Asked Questions
How do I find the half-life if I know the initial and remaining amounts and the time?
Rearrange the decay formula: t½ = t × ln(2) / ln(N₀ / N(t)). For example, if you start with 100 g, have 25 g after 10 hours, then t½ = 10 × ln(2) / ln(100/25) = 10 × 0.6931 / 1.3863 = 5 hours.
What is the difference between half-life and decay constant?
The half-life (t½) is the time for half the sample to decay. The decay constant (λ) is the probability per unit time that a nucleus will decay. They are related by λ = ln(2)/t½. If you have one, you can calculate the other.
Can half-life be negative?
No. A half-life is always a positive time. If your calculation gives a negative value, you likely swapped the initial and remaining amounts or used inconsistent units.
Does the half-life depend on the amount of substance?
No. For first-order processes, the half-life is independent of the initial amount. Whether you start with 1 gram or 1 kilogram, the time to reach half of that amount is the same.
How many half-lives until a substance is considered gone?
Technically, it never reaches zero—it approaches zero asymptotically. In practice, after 10 half-lives, only about 0.1% remains, which is often considered negligible. For safety regulations, “gone” may be defined as a specific fraction, such as 10 half-lives for many radioactive materials.
Why is the half-life formula written with (1/2)^(t/t½) rather than e^(−λt)?
Both are equivalent. The (1/2)^(t/t½) form directly uses the half-life, which is intuitive. The e^(−λt) form is more general and connects to the differential equation dN/dt = −λN. The calculator uses the former for clarity.
Related
Formula used
in a | Initial amount | g | 100 | 0 in t12 | Half-life | h | 6 | 0.000001 in t | Elapsed time | h | 18 | 0 out rem | Remaining amount | g | a * 0.5^(t / t12) | 4 out frac | Fraction remaining | - | 0.5^(t / t12) | 4 out n | Number of half-lives | - | t / t12 | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Normality to g/L Converter & Formula29.220 g/L
- Normality to meq/mL Conversion Calculator1.0000 meq/mL
- Normality Test Q-Q Plot: How to Read It
- Normality Test Results: How to Analyze Them
- Normality Slay the Spire?
- Normality Test for Paired t Test: How to Check