molecalculator

Moles & Molar Mass

Head to Pressure Calculator: Convert Head to PSI

Calculator No. 01-11919 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator converts a fluid head (height of a liquid column) into pressure, and the reverse. You enter the head in meters, the fluid density in kg/m³, and the gravitational acceleration (default 9.81 m/s²), and you get the pressure in pascals, kilopascals, and bar. The formula is the hydrostatic pressure equation: P = ρ × g × h.

Formula

The hydrostatic pressure formula is:

P = ρ × g × h

  • P = pressure (pascals, Pa)
  • ρ (rho) = fluid density (kg/m³)
  • g = gravitational acceleration (m/s², standard 9.81 m/s²)
  • h = head, the vertical height of the fluid column (m)

One pascal equals one newton per square meter (1 Pa = 1 N/m²). To convert to other units: 1 kPa = 1000 Pa, 1 bar = 100,000 Pa, 1 psi ≈ 6894.76 Pa.

Worked Example

Using the default values: head = 10 m, density = 1000 kg/m³ (fresh water), g = 9.81 m/s².

P = 1000 kg/m³ × 9.81 m/s² × 10 m = 98,100 Pa

In kilopascals: 98,100 Pa / 1000 = 98.10 kPa

In bar: 98,100 Pa / 100,000 = 0.981 bar

The calculator shows 98.1 kPa and 0.981 bar, matching the manual calculation.

Assumptions

  • The fluid is static (not moving) and incompressible.
  • Density is uniform throughout the column.
  • Gravity is constant over the height (true for typical engineering heights).
  • Pressure is measured at the bottom of the column, relative to the surface (gauge pressure, not absolute).

When to Use Head vs. Pressure

Head and pressure are two ways to express the same energy per unit weight of fluid. Head is measured in length units (meters, feet) and is independent of fluid density – a pump moving water and a pump moving oil can have the same head but different pressures. Pressure is force per area and depends on density. Engineers often use head for pumps and pipelines because it stays constant regardless of fluid, while pressure gauges read pressure. For example, a pump that provides 20 m of head will lift water 20 m, but if the fluid is mercury (density 13,600 kg/m³), the same head produces much higher pressure.

How to Choose the Right Density

Use the density of the actual fluid at your operating temperature. Water density varies slightly with temperature: 999.7 kg/m³ at 10°C, 998.2 kg/m³ at 20°C, 997.0 kg/m³ at 25°C. For seawater, use about 1025 kg/m³. For common fluids, look up the density in a reference table; never guess. If you are converting pump head to pressure for a specific liquid, use the density of that liquid, not water, unless the liquid is water.

Common Mistakes and Misconceptions

  • Mixing units: Head in feet but density in kg/m³ gives nonsense. Convert all to SI (meters, kg/m³) before calculating.
  • Forgetting gravity: Some simplified formulas use g = 10 m/s², but that introduces ~2% error. Use 9.81 unless you know the local value.
  • Confusing gauge and absolute pressure: The formula gives gauge pressure (relative to the surface). Absolute pressure includes atmospheric pressure (add ~101.3 kPa).
  • Using head as pressure directly: A 10 m head is not 10 kPa; it’s about 98 kPa for water.

Practical Applications

This conversion is used in:

  • Pump sizing: A pump rated for 15 m head will produce a pressure of about 147 kPa when pumping water.
  • Hydrostatic testing: Filling a vertical pipe with water to a certain height creates a known pressure at the bottom.
  • Diving and underwater calculations: Every 10.3 m of seawater adds about 1 atm (101.3 kPa) of pressure.
  • Tank level measurement: A pressure sensor at the bottom of a tank can infer liquid level using the reverse calculation.

Limits of the Formula

The hydrostatic formula assumes a stationary fluid. If the fluid is accelerating (e.g., in a centrifuge or a moving vehicle), additional forces apply. Also, for very tall columns (kilometers), gravity variation becomes non-negligible, but for normal engineering, it’s fine. The formula does not account for compressibility – for gases, density changes with pressure, so this calculator is only accurate for liquids or gases at low pressure where density is nearly constant.

Frequently Asked Questions

How do I convert head to PSI?
Multiply head (in meters) by density (kg/m³) and g (9.81) to get pascals, then divide by 6894.76 to get psi. For water, a quick approximation: 1 m head ≈ 1.42 psi.

Is head the same as pressure?
No. Head is a height of a fluid column, while pressure is force per area. They are related by P = ρgh. Head is independent of fluid type; pressure depends on density.

What is the pressure at 100 feet of water?
First convert feet to meters: 100 ft × 0.3048 = 30.48 m. Then P = 1000 × 9.81 × 30.48 = 299,000 Pa ≈ 43.4 psi.

Why does my pump show low pressure but good flow?
Pressure at the pump discharge depends on the system resistance. If the pump is not dead-headed, the pressure reading may be lower than the maximum head. Check the pump curve; the operating point is where the system curve intersects the pump curve.

Does temperature affect the conversion?
Temperature changes fluid density slightly, so the pressure for a given head changes a little. For water, the density change from 10°C to 30°C is about 0.4%, so the effect is small but not negligible in precise work.

Can I use this for gas?
Only if the gas density is constant, which is rare. For gases, use the ideal gas law to find density at the given pressure and temperature, then use this formula for very small heights. For tall gas columns, density varies with altitude, so the simple formula fails.

Related

Formula used
in h | Head (height of liquid column) | m | 10 | 0
in rho | Fluid density | kg/m³ | 1000 | 0
in g | Gravitational acceleration | m/s² | 9.81 | 0
out P | Pressure | Pa | rho * g * h | 1
out kPa | Pressure in kilopascals | kPa | P / 1000 | 2
out bar | Pressure in bar | bar | P / 100000 | 3

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.