molecalculator

Moles & Molar Mass

How to Find Enthalpy of Vaporization

Calculator No. 01-14623 · Updated · Formula and assumptions shown below

Enthalpy of vaporization 43.57 kJ/mol
Normal boiling point
98.2 °C
Result, rounded to 1 decimal place
Temperature 1
25 °C
Set in the form below
Vapor pressure 1
3.17 kPa
Set in the form below
You enter
Temperature 1 (°C), Vapor pressure 1 (kPa), Temperature 2 (°C), Vapor pressure 2 (kPa)
You get
Enthalpy of vaporization (kJ/mol), Normal boiling point (°C)
Rounding
2 dp · 1 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator finds the enthalpy of vaporization (ΔHvap) of a liquid from vapor pressure data using the Clausius–Clapeyron equation. You enter two sets of temperature and vapor pressure values, and the calculator returns ΔHvap in kJ/mol, along with the normal boiling point if one of the pressures is 1 atm. This is a standard method for pure liquids when you have experimental vapor pressure measurements.

Formula

The Clausius–Clapeyron equation relates vapor pressure and temperature:

ln(P2/P1) = -ΔHvap/R × (1/T2 – 1/T1)

Rearranged to solve for ΔHvap:

ΔHvap = -R × ln(P2/P1) / (1/T2 – 1/T1)

Where:

  • ΔHvap = enthalpy of vaporization (J/mol, then converted to kJ/mol)
  • R = gas constant = 8.314 J/(mol·K)
  • P1, P2 = vapor pressures at T1 and T2 (any consistent pressure unit, but the calculator uses kPa)
  • T1, T2 = absolute temperatures in Kelvin (K = °C + 273.15)

The normal boiling point is found by setting P2 = 101.325 kPa (1 atm) and solving for T2 using the same equation.

Worked Example

Using the default values for water: T1 = 25 °C, P1 = 3.17 kPa; T2 = 50 °C, P2 = 12.35 kPa.

Step 1: Convert temperatures to Kelvin.

T1 = 25 + 273.15 = 298.15 K

T2 = 50 + 273.15 = 323.15 K

Step 2: Compute 1/T values.

1/T1 = 1/298.15 = 0.0033540 K-1

1/T2 = 1/323.15 = 0.0030945 K-1

Step 3: Compute the ratio of pressures.

P2/P1 = 12.35 / 3.17 = 3.896

ln(3.896) = 1.360

Step 4: Apply the Clausius–Clapeyron equation.

ΔHvap = -8.314 × 1.360 / (0.0030945 – 0.0033540) = -11.307 / (-0.0002595) = 43,570 J/mol = 43.57 kJ/mol

The calculator shows 43.57 kJ/mol (rounded to 2 decimals).

Assumptions

  • The vapor behaves as an ideal gas.
  • The molar volume of the liquid is negligible compared to that of the vapor.
  • ΔHvap is constant over the temperature range (true for narrow ranges).
  • The two data points are accurate and measured at equilibrium.

When to Use This Method

Use this calculator when you have two reliable vapor pressure measurements at different temperatures for a pure liquid. It works best over a narrow temperature range (e.g., 10–30 °C apart) because ΔHvap actually varies with temperature. For a wider range, you would need a more complex equation (e.g., Antoine equation) or calorimetry. This method is common in chemistry labs for determining ΔHvap of volatile liquids like water, ethanol, or acetone.

How to Read the Result

The enthalpy of vaporization is the energy required to vaporize one mole of the liquid at constant pressure. A higher value means stronger intermolecular forces (e.g., hydrogen bonding in water gives ~40.7 kJ/mol at 25 °C). The normal boiling point output is the temperature at which the vapor pressure equals 1 atm (101.325 kPa).

Common Mistakes

  • Using Celsius instead of Kelvin: Always add 273.15 to °C before plugging into the equation. Forgetting this leads to huge errors.
  • Mixing pressure units: The ratio P2/P1 is unitless, so you can use any unit, but both must be the same. If you mix kPa and atm, the ratio is wrong.
  • Reversing T1/T2: The equation is sensitive to order. Make sure T2 is the higher temperature and P2 is the corresponding higher pressure.
  • Assuming ΔHvap is constant over large ranges: The Clausius–Clapeyron equation is an approximation; for a 100 °C range, the error can be several percent.
  • Forgetting to convert J to kJ: The calculator does this, but if you compute manually, remember 1 kJ = 1000 J.

Tips

  • Use data points that are far apart (e.g., 20–30 °C) to reduce the relative error in the slope, but not so far that ΔHvap changes significantly.
  • If you have more than two data points, plot ln(P) vs 1/T and take the slope (which equals -ΔHvap/R) for a better estimate.
  • Check your pressures: for water at 25 °C, the vapor pressure is about 3.17 kPa. If your data gives a wildly different ΔHvap (e.g., 100 kJ/mol), double-check the units and temperature conversion.
  • For accurate lab work, use a manometer or a pressure sensor that is calibrated.

Troubleshooting

If the calculator shows “Cannot compute” or a negative ΔHvap: Check that T2 > T1 and P2 > P1. Vapor pressure always increases with temperature, so if your data violates this, you likely entered the values in the wrong order.

If the result seems too high or too low: Verify that both pressures are in the same unit (the calculator assumes kPa, but you can convert: 1 atm = 101.325 kPa, 1 torr = 0.133322 kPa). Also, ensure temperatures are in °C as entered, not already in Kelvin.

If the normal boiling point is unrealistic (e.g., negative or > 500 °C): This often happens when the two data points are too close together, making the extrapolation to 101.325 kPa unreliable. Use data points that bracket the boiling point if possible.

If you suspect your data is bad: Re-measure the vapor pressure at each temperature, ensuring the liquid is pure and the system is at equilibrium (no bubbles forming).

Frequently Asked Questions

Q: Can I use this calculator for any liquid?
A: Yes, as long as the liquid is pure and you have two vapor pressure measurements. The Clausius–Clapeyron equation applies to all pure substances.

Q: What is the difference between enthalpy of vaporization and heat of vaporization?
A: They are the same thing; “enthalpy of vaporization” is the formal thermodynamic term, while “heat of vaporization” is commonly used informally.

Q: Why does water have a high enthalpy of vaporization?
A: Water has strong hydrogen bonds between molecules, requiring more energy to break them during vaporization. That’s why ΔHvap for water (~40.7 kJ/mol) is higher than for non-polar liquids like hexane (~28.9 kJ/mol).

Q: Can I use this method to find the enthalpy of sublimation?
A: Yes, the same equation works for solid-vapor equilibrium (sublimation), but you need vapor pressure data for the solid phase.

Q: What if I only have one vapor pressure data point?
A: You cannot use the two-point form. You would need to know the normal boiling point (vapor pressure = 101.325 kPa at that temperature) as a second point, or use a correlation like Trouton’s rule (ΔHvap ≈ 85 J/(mol·K) × Tb), but that’s only an estimate.

Q: How accurate is the Clausius–Clapeyron equation?
A: It’s accurate to within a few percent over a narrow temperature range (e.g., 10–30 °C). For wider ranges, the Antoine equation or a calorimetric measurement is more accurate.

Related

Formula used
in t1 | Temperature 1 | °C | 25 | -273.15
in p1 | Vapor pressure 1 | kPa | 3.17 | 0
in t2 | Temperature 2 | °C | 50 | -273.15
in p2 | Vapor pressure 2 | kPa | 12.35 | 0
out hvap | Enthalpy of vaporization | kJ/mol | -8.314 * ln(p2/p1) / (1/(t2+273.15) - 1/(t1+273.15)) / 1000 | 2
out bp | Normal boiling point | °C | 1/(1/(t1+273.15) - 8.314*ln(101.325/p1)/(hvap*1000)) - 273.15 | 1

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →