molecalculator

Moles & Molar Mass

How to Find k in Thermodynamics

Calculator No. 01-14695 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This guide shows you how to find the rate constant k in thermodynamics and chemical kinetics. You will learn the Arrhenius equation method, how to determine k from experimental data, and how to use the Eyring equation from transition state theory. You will need a calculator, the activation energy, temperature, and either a known rate constant at one temperature or experimental concentration-time data.

Formula

The Arrhenius equation is:

k = A · e−Ea/(R·T)

  • k – rate constant (units depend on reaction order; for first-order, s−1)
  • A – pre-exponential factor (same units as k, often s−1)
  • Ea – activation energy (J/mol)
  • R – gas constant, 8.31446261815324 J/(mol·K)
  • T – absolute temperature (K)

If you have two rate constants at two temperatures, you can solve for Ea and then find k at any temperature. The two-point form is:

ln(k2/k1) = −(Ea/R) · (1/T2 − 1/T1)

Worked Example

Using the calculator defaults: Ea = 50000 J/mol, T = 298.15 K, A = 1×1013 s−1.

Step 1: Compute the exponent: −Ea/(R·T) = −50000 / (8.31446261815324 × 298.15) = −50000 / 2478.99 ≈ −20.1695

Step 2: Compute e−20.1695 ≈ 1.734 × 10−9

Step 3: Multiply by A: k = 1×1013 × 1.734×10−9 = 1.734×104 s−1

The calculator shows k = 17340.0 s−1 (rounded to 6 significant figures).

Assumptions

  • The reaction follows Arrhenius behavior (A and Ea are constant over the temperature range).
  • Temperature is in kelvin (K).
  • Activation energy is in joules per mole (J/mol). If you have kJ/mol, multiply by 1000.
  • The pre-exponential factor has the same units as k.

When to Use This

Use the Arrhenius equation when you need the rate constant at a specific temperature, or when you want to predict how temperature affects reaction speed. In thermodynamics, k appears in the rate law, not in equilibrium constants (which use K). This calculator is for chemical kinetics, a branch of physical chemistry that connects thermodynamics and reaction rates.

How to Read the Result

The output is the rate constant k at the given temperature. A larger k means a faster reaction. For first-order reactions, the unit s−1 is standard. For second-order, the unit would be L/(mol·s), but the calculator assumes first-order units (s−1). If your reaction is not first-order, adjust the units of A accordingly.

Common Mistakes

  • Using Celsius instead of Kelvin: Always convert °C to K by adding 273.15.
  • Mixing energy units: If Ea is given in kJ/mol, convert to J/mol (multiply by 1000) before using R = 8.314.
  • Forgetting the negative sign: The exponent is −Ea/(RT), not positive.
  • Using the wrong gas constant: R = 8.314 J/(mol·K) matches J/mol for Ea. If you use R = 0.0821 L·atm/(mol·K), you must convert Ea to atm·L units.
  • Assuming A is constant: A can vary slightly with temperature for some reactions, but the Arrhenius equation assumes it is constant.

Tips

  • When you have data at multiple temperatures, plot ln(k) vs 1/T. The slope is −Ea/R and the intercept is ln(A). This is the most reliable way to find both A and Ea.
  • If you only have one k value and want to find k at another temperature, use the two-point form to first solve for Ea if you have two temperatures; otherwise, you need Ea from literature.
  • For reactions in solution, consider the Eyring equation from transition state theory: k = (kBT/h) · e−ΔG‡/(RT), where kB is Boltzmann’s constant and h is Planck’s constant. This gives a more thermodynamic interpretation.
  • Always check units: if your k is in s−1, then A must also be in s−1.

Troubleshooting

  • Result is too large or too small: Check your activation energy units. A typical Ea is 20–100 kJ/mol, which is 20000–100000 J/mol. If you used 50 instead of 50000, the exponent becomes tiny and k approaches A.
  • Negative k? The calculator does not produce negative k because the exponential is always positive. If you see a negative, check your input for a negative Ea (which is physically impossible).
  • Cannot compute: If you entered a temperature below 0 K, the calculator will reject it. Use absolute temperatures only.
  • Inconsistent with experimental data: The Arrhenius equation is an approximation. If your data deviates significantly, consider that A and Ea may not be constant, or that the reaction has a different mechanism.

Frequently Asked Questions

What is the difference between k and K in thermodynamics?

k (lowercase) is the rate constant, which tells how fast a reaction proceeds. K (uppercase) is the equilibrium constant, which tells the ratio of products to reactants at equilibrium. They are related by thermodynamics but not the same.

Can I find k from ΔG?

Not directly. ΔG gives the equilibrium constant K via ΔG° = −RT ln K. The rate constant k depends on the activation free energy ΔG‡ via the Eyring equation: k = (kBT/h) e−ΔG‡/(RT). You need the activation barrier, not the overall free energy change.

What if I only have the half-life?

For a first-order reaction, k = ln(2)/t1/2. For example, if t1/2 = 100 s, k = 0.693/100 = 0.00693 s−1. For other orders, the relationship differs.

How do I find k from experimental concentration vs time data?

Plot the data according to the integrated rate law. For first-order, plot ln[A] vs t; the slope is −k. For second-order, plot 1/[A] vs t; the slope is k. For zero-order, plot [A] vs t; the slope is −k.

Why does k increase with temperature?

Because the exponential term e−Ea/(RT) increases as T increases (since the exponent becomes less negative). Higher temperature gives more molecules enough energy to overcome the activation barrier.

What are typical units for k?

Units depend on the overall reaction order. Zero-order: mol/(L·s). First-order: s−1. Second-order: L/(mol·s). Third-order: L2/(mol2·s). The Arrhenius pre-factor A must have the same units as k.

Related

Formula used
in Ea | Activation energy | J/mol | 50000 | 0
in T | Temperature | K | 298.15 | 0
in A | Pre-exponential factor | 1/s | 1e13 | 0
out k | Rate constant | 1/s | A * exp(-Ea / (8.31446261815324 * T)) | 6

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →