molecalculator

Moles & Molar Mass

How to Make Molecular Oxygen (O₂)

Guide 01-11623 · Updated · Step by step

This guide explains how to produce molecular oxygen (O₂) in a laboratory or home setting using safe, well-established chemical methods. You will learn the principle behind each method, the exact steps to follow, and how to handle the gas safely. Before starting, ensure you have proper ventilation, safety goggles, and gloves, and review the safety data sheets (SDS) for all chemicals involved.

What You’ll Need

  • Hydrogen peroxide (3% or 6% solution, available at pharmacies)
  • Manganese dioxide (MnO₂) as a catalyst (or a fresh potato slice as a substitute)
  • A conical flask or glass bottle
  • A rubber stopper with a glass tube or a delivery tube
  • A trough or large bowl filled with water
  • Several test tubes or small bottles to collect gas
  • A wooden splint and a lighter (for testing)
  • Safety goggles and gloves

Step-by-Step

  1. Set up the apparatus. Place the conical flask on a stable surface. Insert the delivery tube into the rubber stopper, ensuring a tight fit. Fill the trough or bowl about two-thirds full with water.
  2. Prepare the gas collection. Fill a test tube completely with water, then invert it into the trough so that the mouth is submerged. Hold it in place with a clamp or your hand. The tube should remain filled with water (no air).
  3. Add the catalyst. Add a small spatula tip (about 0.5 g) of manganese dioxide to the flask. If using a potato slice, cut a thin piece and add it instead.
  4. Add the hydrogen peroxide. Carefully pour about 20 mL of 3% hydrogen peroxide into the flask. Immediately insert the stopper with the delivery tube. The end of the delivery tube should be placed under the mouth of the inverted test tube in the trough.
  5. Collect the gas. As the reaction proceeds, bubbles of oxygen will displace the water in the test tube. Wait until the tube is almost full of gas (a small amount of water may remain).
  6. Remove the tube. While the tube is still underwater, slide a glass plate or your thumb over the mouth, then lift it out of the water. Keep the tube upright (mouth downward if using a plate) to prevent gas escape.
  7. Test for oxygen. Light a wooden splint, blow out the flame so it is glowing, then insert the glowing splint into the tube. If the splint relights with a pop or bright flame, the gas is oxygen.
  8. Dispose of waste. After the reaction stops, the remaining liquid is mostly water with a little hydrogen peroxide and manganese dioxide. Dilute with plenty of water and pour down the drain (check local regulations). Rinse the flask and delivery tube.

Common Mistakes

  • Using too strong hydrogen peroxide. 30% or higher can react violently and splatter. Stick to 3% or 6% for safety.
  • Not sealing the delivery tube. If the stopper or tube leaks, gas escapes and collection is slow.
  • Collecting gas too early. The first few bubbles may be air from the flask. Wait a few seconds before placing the tube over the delivery tube.
  • Inverting the tube with air. If the tube contains air, you are collecting a mixture, not pure oxygen.
  • Testing with a flaming splint. A flaming splint can ignite hydrogen gas (if any) and cause a small explosion. Always use a glowing splint.

Tips

  • Use a fresh catalyst. Manganese dioxide can be reused but loses activity over time.
  • For a faster reaction, warm the hydrogen peroxide slightly (not above 40°C) before adding the catalyst.
  • If you don’t have manganese dioxide, a few drops of potassium iodide solution or a piece of raw potato (contains catalase enzyme) also work.
  • Collect multiple tubes of oxygen to have enough for experiments.
  • Keep the delivery tube tip just below the water surface to avoid backflow.

Troubleshooting

  • No bubbles appear. Check that the stopper is tight and the delivery tube is not blocked. If using potato, it may be too small; add more. If using MnO₂, it may be exhausted; add a fresh pinch.
  • Reaction too slow. Add a little more catalyst or use a slightly higher concentration of hydrogen peroxide (still under 10%). Do not heat strongly.
  • Reaction too fast (foaming). The peroxide may be too concentrated or the catalyst too much. Remove the stopper briefly to slow down, and wear protective gear.
  • Gas does not relight a glowing splint. The gas may be diluted with air. Discard the first tube and collect a fresh one, ensuring the tube is completely water-filled before collection.
  • Water backs up into the delivery tube. This happens if the tube is too deep or the reaction stops. Remove the flask from the trough immediately.

Frequently Asked Questions

Is it safe to make oxygen at home?

Yes, with 3% hydrogen peroxide and a catalyst, the reaction is mild. Always work in a well-ventilated area, avoid flames, and wear goggles. Do not inhale the gas directly.

Can I use electrolysis of water instead?

Yes, electrolysis of water (with a small amount of salt or acid) produces oxygen at the anode and hydrogen at the cathode. However, hydrogen is flammable, so extra care is needed. The hydrogen peroxide method is simpler and safer.

Why does a glowing splint relight in oxygen?

Oxygen supports combustion. A glowing splint has a hot ember; in pure oxygen, the increased oxygen concentration causes it to ignite into a flame.

How much oxygen can I produce?

From 20 mL of 3% hydrogen peroxide, you can produce about 200 mL of oxygen gas at room temperature. The exact amount depends on concentration and catalyst efficiency.

Can I store the oxygen?

You can store it in a gas syringe or a sealed container for a short time, but it will slowly diffuse through rubber or plastic. For longer storage, use a gas cylinder (not recommended for home).

What is the chemical equation?

The decomposition is: 2 H₂O₂ → 2 H₂O + O₂. Manganese dioxide acts as a catalyst and is not consumed.

Related

General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →