This guide explains how to measure the enthalpy change (ΔH) of a chemical reaction using a simple calorimetry experiment. You’ll learn the step-by-step procedure, calculations, and common pitfalls. By the end, you’ll be able to determine whether a reaction is exothermic (releases heat) or endothermic (absorbs heat) and quantify the energy change per mole of reactant.
What You’ll Need
- Polystyrene (Styrofoam) cup with lid – acts as an insulated calorimeter
- Thermometer (0.1 °C precision) or temperature probe
- Measuring cylinder (for volumes)
- Digital balance (accurate to 0.01 g)
- Reagents for the reaction (e.g., HCl solution and NaOH solution for neutralization)
- Stirrer (glass rod or magnetic stirrer)
- Stopwatch or timer
- Graph paper or data logger (optional)
Step-by-Step
- Set up the calorimeter: Place the polystyrene cup inside a larger beaker for stability. Put the lid on with a hole for the thermometer. This minimizes heat loss to the surroundings.
- Measure the reagents: Using a measuring cylinder, measure a known volume of one reactant (e.g., 50.0 mL of 1.0 M HCl). Record the exact concentration and volume. Weigh the solid reactant if used, or measure the second solution.
- Record initial temperature: Add the first solution to the cup. Place the thermometer through the lid, stir gently, and record the temperature every 30 seconds until it is stable (about 1–2 minutes). This is the initial temperature (Ti).
- Add the second reactant: Quickly but carefully pour the second solution (or add the solid) into the cup. Replace the lid immediately. Start the timer.
- Stir and monitor temperature: Stir continuously. Record the temperature every 15–30 seconds. Watch for the maximum (for exothermic) or minimum (for endothermic) temperature. Continue recording until the temperature starts to drift back toward room temperature.
- Note the final temperature: The highest (or lowest) reading is the final temperature (Tf). If the temperature change is slow, plot temperature vs. time and extrapolate back to the moment of mixing to get the true ΔT.
- Calculate the heat absorbed by the solution: Use the formula q = m × c × ΔT, where m is the total mass of the solution (assume density ≈ 1.00 g/mL for dilute aqueous solutions, so mass in grams ≈ total volume in mL), c is the specific heat capacity of the solution (for dilute aqueous solutions, use 4.18 J/g·°C), and ΔT = Tf − Ti.
- Account for heat absorbed by the calorimeter: If you know the heat capacity of the calorimeter (Ccal), add qcal = Ccal × ΔT. For a simple polystyrene cup, this is often small and can be ignored, but for precise work, calibrate it.
- Convert to enthalpy change per mole: Divide the total heat (qtotal) by the number of moles of the limiting reactant (n). The enthalpy change is ΔH = −qtotal / n. The negative sign is because heat released by the reaction is absorbed by the solution.
- Report the result: State ΔH in kJ/mol, with the sign indicating exothermic (negative) or endothermic (positive). Include the temperature and concentration conditions.
Common Mistakes
- Ignoring heat loss: Not insulating the cup well or leaving the lid off leads to underestimated ΔT and thus lower ΔH.
- Using the wrong mass: Forgetting that the mass of the solution includes both reactants and any solvent. Use total mass, not just the mass of the limiting reactant.
- Assuming density is 1.00 g/mL for non-dilute solutions: This only holds for dilute aqueous solutions. For concentrated acids or organic solvents, look up the density.
- Not accounting for the heat capacity of the thermometer: In precise work, the thermometer absorbs heat, but for school labs this is negligible.
- Mixing up sign convention: Remember ΔH is negative for exothermic (heat released) and positive for endothermic (heat absorbed). The formula q = m·c·ΔT gives heat absorbed by the solution, so the reaction’s ΔH is the negative of that.
Tips
- Use a lid with a small hole for the thermometer to reduce evaporation and heat loss.
- Stir continuously but gently to ensure even temperature distribution without splashing.
- For reactions that are slow, plot temperature vs. time and extrapolate the initial and final temperatures to the moment of mixing to correct for heat exchange with the surroundings.
- Use a large excess of one reactant to ensure the limiting reactant is fully consumed, making the mole calculation straightforward.
- Repeat the experiment 2–3 times and average the results to improve accuracy.
Troubleshooting
- Temperature change is too small to measure: Use more concentrated solutions or a larger amount of reactants. Also check that the reaction is actually occurring (e.g., proper mixing).
- Temperature keeps rising after mixing: The reaction may be slow (e.g., dissolving solids). Wait until the temperature reaches a plateau, or use a graphical extrapolation method.
- Result is far from literature value: Likely due to heat loss. Improve insulation, use a lid, and stir faster. Also check that you used the correct specific heat capacity and density.
- Negative ΔT for an exothermic reaction: You may have misread the thermometer or the reaction is actually endothermic. Double-check your initial and final readings.
Frequently Asked Questions
- What is the difference between heat and enthalpy? Heat (q) is the energy transferred due to temperature difference. Enthalpy (H) is a state function that includes internal energy plus pressure-volume work. At constant pressure (common in open calorimetry), the heat change equals the enthalpy change (qp = ΔH).
- Why do I use the specific heat of water for the solution? For dilute aqueous solutions, the solution is mostly water, so its specific heat is close to 4.18 J/g·°C. For more accurate work, you can measure the specific heat of the actual solution.
- How do I calibrate the calorimeter? Mix a known amount of hot and cold water and measure the final temperature. The heat lost by hot water equals heat gained by cold water plus the calorimeter. From that, calculate Ccal = qlost / ΔTcal.
- Can I measure enthalpy change for any reaction? You can measure for reactions that involve heat exchange and are safe to perform in a calorimeter. For reactions that are too violent or produce gases, you may need a bomb calorimeter (constant volume) instead.
- What is the difference between constant pressure and constant volume calorimetry? A coffee-cup calorimeter operates at constant pressure, giving ΔH. A bomb calorimeter operates at constant volume, giving ΔU (internal energy change). For reactions involving gases, ΔH and ΔU differ by ΔngasRT.
- Why is my calculated ΔH slightly different from the textbook value? Textbook values are usually at standard conditions (25 °C, 1 atm, all solutions at infinite dilution). Your experiment is at different concentrations and temperatures, and heat losses cause systematic error.
Related
General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.