The initial rate of reaction is the instantaneous rate measured at time zero, just after reactants are mixed. Its formula is rate = k[A]m[B]n, where k is the rate constant and m and n are the reaction orders with respect to reactants A and B. You determine the initial rate experimentally by measuring the change in concentration of a reactant or product over the first few moments and calculating the slope of the concentration-versus-time curve at t = 0.
Formula
The general rate law for a reaction aA + bB → products is:
Initial rate = k [A]0m [B]0n
where:
- k – rate constant (units depend on overall order, e.g., s−1 for first order, L·mol−1·s−1 for second order)
- [A]0, [B]0 – initial molar concentrations (mol/L)
- m, n – reaction orders (often 0, 1, or 2; determined experimentally, not from stoichiometric coefficients)
The overall order is m + n. The units of k adjust so that the rate always comes out in mol/(L·s) (or M/s).
Worked Example
Using the calculator defaults: [A]0 = 0.50 mol/L, [B]0 = 0.50 mol/L, k = 0.10 (units L·mol−1·s−1 for overall second order), m = 1, n = 1.
Initial rate = 0.10 × (0.50)1 × (0.50)1 = 0.10 × 0.25 = 0.025 mol/(L·s).
The calculator shows 0.0250 mol/(L·s) (4 decimal places).
Assumptions
- The rate law is of the form rate = k[A]m[B]n (no more complex terms).
- The reaction is studied at constant temperature; k changes with temperature.
- The orders m and n are known (from experiments or given).
- Concentrations are in mol/L and time in seconds (convert if needed).
How to Measure the Initial Rate Experimentally
In practice, you don’t get the rate directly from the rate law—you measure it. The initial rate is the slope of the concentration–time curve at t = 0.
- Mix the reactants quickly (often in a stopped-flow apparatus for fast reactions).
- Record concentration of a reactant or product at short time intervals (e.g., every 0.1 s).
- Plot concentration versus time. The slope at t = 0 is the initial rate.
- Repeat with different initial concentrations to find the orders.
For example, if [A] drops from 0.500 M to 0.490 M in the first 0.20 s, the initial rate ≈ (0.500 – 0.490)/0.20 = 0.050 M/s (assuming the curve is nearly linear at the start).
Determining the Orders (Method of Initial Rates)
To find m and n, run several trials changing one initial concentration at a time while keeping others constant. Compare how the initial rate changes.
- If doubling [A] doubles the rate, m = 1 (first order in A).
- If doubling [A] quadruples the rate, m = 2 (second order in A).
- If changing [A] has no effect on the rate, m = 0 (zero order in A).
Example: Trial 1: [A]=0.10 M, [B]=0.10 M, rate=0.0020 M/s. Trial 2: [A]=0.20 M, [B]=0.10 M, rate=0.0080 M/s. Since rate increases by a factor of 4 when [A] doubles, m=2. Trial 3: [A]=0.10 M, [B]=0.20 M, rate=0.0020 M/s (no change), so n=0. Then plug any trial into rate = k[A]2[B]0 to find k: 0.0020 = k(0.10)2 → k = 0.20 L·mol−1·s−1.
Common Mistakes
- Using stoichiometric coefficients as orders: Orders come from experiments, not from the balanced equation (except for elementary steps).
- Forgetting to convert time units: If time is in minutes, the rate will be in M/min; convert to seconds if needed.
- Confusing initial rate with average rate: The initial rate is the instantaneous slope at t=0, not the average over a long interval.
- Ignoring temperature: k is temperature-dependent; always record the temperature.
- Using the wrong units for k: For overall order 2, k must be L·mol−1·s−1; for order 1, s−1.
Why the Initial Rate Matters
The initial rate is used because at t=0, the concentrations are exactly known (you prepared them), and there are no product molecules yet to interfere (e.g., reverse reaction or catalysis by product). This makes it the cleanest measurement for determining the rate law. Later in the reaction, concentrations change and reverse reactions become significant, complicating the analysis.
Also, the initial rate is directly proportional to k and the initial concentrations, so it’s the standard way to compare reaction speeds under different conditions.
Limits of the Formula
The simple rate law rate = k[A]m[B]n works for many reactions, but not all. Some reactions have more complex rate laws, such as:
- Rate = k[A]/(1 + K[B]) (Michaelis–Menten type)
- Rate = k[A]2/(1 + k'[B]) (inhibition)
- Rate laws with fractional orders (e.g., 0.5) for chain reactions
Also, the rate law only applies under constant temperature and for the specific mechanism. At very high concentrations, activity coefficients deviate from 1, so concentrations should be replaced by activities for exact work.
Frequently Asked Questions
What is the difference between initial rate and instantaneous rate?
The initial rate is the instantaneous rate at t=0. Instantaneous rate is the slope of the concentration–time curve at any given moment; the initial rate is just that slope at the very start.
Can I find the initial rate from a graph of concentration vs time?
Yes. Draw a tangent line to the curve at t=0 and calculate its slope (Δ[concentration]/Δt). That slope is the initial rate. Use a large, clear graph for accuracy.
Why can’t I just use the stoichiometric coefficients as the orders?
Because the rate law reflects the mechanism, not the overall balanced equation. For an elementary reaction (one step), the orders equal the molecularities, but most reactions proceed through multiple steps, and the slow step determines the rate law.
What are the units of the rate constant k?
They depend on the overall order. For zero order: mol/(L·s). For first order: s−1. For second order: L·mol−1·s−1. For nth order: Ln−1·mol−(n−1)·s−1.
Does the initial rate depend on the presence of a catalyst?
Yes. A catalyst changes the mechanism and lowers the activation energy, which changes k and thus the initial rate. The form of the rate law may also change.
How do I calculate k if I only have one trial?
You need the orders first. If you know the orders (e.g., from literature or given), plug the initial concentrations and measured initial rate into the rate law and solve for k. Without orders, you need at least two trials.
Related
Formula used
in cA | Initial concentration of A | mol/L | 0.50 | 0 in cB | Initial concentration of B | mol/L | 0.50 | 0 in k | Rate constant k | (units vary) | 0.10 | 0 in m | Order in A | - | 1 | 0 in n | Order in B | - | 1 | 0 out rate | Initial rate | mol/(L·s) | k * cA^m * cB^n | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Within 10 Percent Calculator – How to Use It5.00 %
- W/W Percentage Calculator: Formula & Examples2.92 %
- Percent Equation: Formula & How to Use It
- Percent of a Number Calculator: Find It Instantly20.00 %
- UWW GPA Calculator: How to Compute Your GPA
- PPM to w/w Calculator: Convert Easily5.0000 %