The NOAA Relative Humidity Calculator is a tool that computes relative humidity (RH) from air temperature and dew point temperature using the formula developed by the U.S. National Oceanic and Atmospheric Administration (NOAA). You enter the air temperature and dew point (both in °C or °F), and it returns the relative humidity as a percentage.
Formula
The calculator uses the Magnus formula (a standard approximation) to compute the saturation vapor pressure (es) and actual vapor pressure (e), then takes their ratio:
RH = (e / es) × 100%
where:
- e = 6.1094 × exp(17.625 × Td / (243.04 + Td)) — actual vapor pressure (hPa), based on dew point Td (°C)
- es = 6.1094 × exp(17.625 × T / (243.04 + T)) — saturation vapor pressure (hPa), based on air temperature T (°C)
- T = air temperature in °C
- Td = dew point temperature in °C
This is the same formulation used by NOAA’s physical sciences laboratory for meteorological calculations. The constants 17.625 and 243.04 are empirical coefficients that give accurate results over the typical atmospheric range (−40°C to +50°C).
Worked Example
Using the default values: Air temperature T = 25°C, Dew point Td = 15°C.
Step 1: Compute the saturation vapor pressure at T = 25°C:
es = 6.1094 × exp(17.625 × 25 / (243.04 + 25)) = 6.1094 × exp(440.625 / 268.04) = 6.1094 × exp(1.6436) ≈ 6.1094 × 5.1721 ≈ 31.60 hPa
Step 2: Compute the actual vapor pressure at Td = 15°C:
e = 6.1094 × exp(17.625 × 15 / (243.04 + 15)) = 6.1094 × exp(264.375 / 258.04) = 6.1094 × exp(1.0246) ≈ 6.1094 × 2.7858 ≈ 17.02 hPa
Step 3: Compute relative humidity:
RH = (17.02 / 31.60) × 100% ≈ 53.9%
The calculator returns 53.9%, matching the default output.
Assumptions
- The Magnus formula is an approximation valid for temperatures between about −40°C and +50°C.
- Air is assumed to be a mixture of ideal gases; the formula works for standard atmospheric pressure (1013.25 hPa).
- The dew point is assumed to be ≤ air temperature (if dew point > air temperature, the result exceeds 100%, which indicates supersaturation or a data error).
- No account is taken of pressure variations; at high altitudes, the same formula still gives RH accurately because RH is a ratio of vapor pressures, which scale similarly with pressure.
How to Use the Calculator
Enter the air temperature and the dew point temperature in the same unit (the calculator converts internally). The output is the relative humidity percentage, along with the saturation and actual vapor pressures in hectopascals (hPa).
Typical usage:
- Weather observation: You have a thermometer and a dew point sensor (e.g., a chilled mirror hygrometer) and want RH.
- HVAC design: You know the indoor temperature and dew point from a psychrometric chart and need RH for comfort or condensation risk.
- Greenhouse or storage monitoring: You measure temperature and dew point with a logger and want to know if RH is too high for mold prevention.
If you only have wet-bulb and dry-bulb temperatures, you need a psychrometric chart or a more complex formula—this calculator is not designed for that input.
Common Mistakes and Misconceptions
- Mixing up dew point and wet-bulb temperature. Dew point is the temperature at which air becomes saturated (RH = 100%) at constant pressure. Wet-bulb temperature is lower than dew point when RH < 100% and requires a different calculation. Using wet-bulb in this calculator gives a wrong RH.
- Unit errors. If you enter °F but the formula expects °C, the result will be nonsense. Always convert to °C first (or use a calculator that handles units).
- Forgetting that RH is temperature-dependent. RH changes when temperature changes even if the moisture content (vapor pressure) stays constant. A room at 20°C with a dew point of 10°C has RH ≈ 52%, but if you heat it to 25°C without adding moisture, RH drops to about 38%.
- Thinking RH above 100% is possible in normal air. In the atmosphere, RH rarely exceeds 100% (fog and clouds can be slightly supersaturated, but not by much). If your calculation shows >100%, check your inputs.
How Does It Compare to Other RH Formulas?
The Magnus formula used here is one of several empirical approximations. Others include the Goff-Gratch equation (more accurate but more complex) and the Arden Buck equation (similar accuracy). The differences are small—usually less than 1% RH over the range −20°C to +40°C. For most practical purposes, the NOAA formula is sufficient.
Some online calculators use a simpler approximation: RH ≈ 100 × (112 − 0.1T + Td) / (112 + 0.9T). This is a quick linear estimate but can be off by several percent. The NOAA formula is more accurate and is the one used in professional meteorology.
Limitations and Practical Notes
The formula assumes a flat water surface. Over ice, the saturation vapor pressure is lower, so RH over ice at subzero temperatures would be slightly different (the formula still works for liquid water down to −40°C, but for ice you’d need a different coefficient).
Also, the calculator gives the instantaneous RH. In real-world measurements, sensor accuracy matters: a typical consumer hygrometer has an accuracy of ±3–5% RH, while a good dew point sensor is accurate to ±0.2°C, which translates to about ±1% RH at moderate temperatures.
For agricultural or meteorological use, you may need to convert RH to vapor pressure deficit (VPD) or absolute humidity. Those require additional calculations (which you can do with other tools on this site).
Frequently Asked Questions
What is the difference between relative humidity and dew point?
Relative humidity is the ratio of the current water vapor pressure to the maximum possible at the current temperature, expressed as a percentage. Dew point is the temperature to which air must be cooled (at constant pressure) to become saturated. A high dew point means more moisture in the air; a low dew point means dry air. RH combines both temperature and moisture, so it can change with temperature even when moisture stays constant.
Can I use this calculator for freezing temperatures?
Yes, down to about −40°C. The Magnus formula is valid for that range. However, below 0°C, the saturation vapor pressure over ice is slightly lower than over liquid water, so the RH over ice would be a bit different. For most purposes, the difference is small (a few percent) and only matters for very precise meteorological work.
How do I convert °F to °C for the inputs?
Use the formula: °C = (°F − 32) × 5/9. For example, 68°F = (68 − 32) × 5/9 = 20°C. Many online calculators, including this one, can handle unit conversion if you provide it, but the formula itself expects °C.
Why does my hygrometer show a different RH than this calculator?
Hygrometers measure RH directly using a sensor (capacitive or resistive), which can drift or be affected by contaminants. This calculator computes RH from temperature and dew point, which is a more fundamental measurement. If your hygrometer is calibrated and the dew point is measured accurately, the values should agree within the sensor’s accuracy. If they differ significantly, one of the measurements is off.
What is a comfortable RH for indoor spaces?
Most people find 30–50% RH comfortable. Below 30% can cause dry skin and static electricity; above 50% can promote mold growth and make the air feel stuffy. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) recommends 30–60% RH for occupied spaces, with 40–50% ideal.
Does atmospheric pressure affect relative humidity?
Not directly. RH is the ratio of vapor pressure to saturation vapor pressure, and both are affected similarly by pressure changes (e.g., at altitude). The ratio remains nearly constant. However, pressure does affect the dew point calculation if you use a psychrometer, but not in this formula.
Related
Formula used
in t | Air temperature | °C | 25 | -40 | 60 in td | Dew point temperature | °C | 15 | -40 | 60 out rh | Relative humidity | % | 100 * (exp((17.625 * td) / (243.04 + td)) / exp((17.625 * t) / (243.04 + t))) | 1 out es | Saturation vapor pressure | hPa | 6.1094 * exp((17.625 * t) / (243.04 + t)) | 2 out e | Actual vapor pressure | hPa | 6.1094 * exp((17.625 * td) / (243.04 + td)) | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- DNA to RNA in the Nucleus: How Transcription Works0.2000 mol/L
- DNA Sequence Example Code: A Practical Guide0.2000 mol/L
- RNA Sequence Reverse Complement Tool
- DNA Sequence Quality Q15: What It Means
- T7 RNA Polymerase Sequence: Full Gene & Key Features97.5 kDa
- T4 RNA Ligase 2 Sequence & Function15,485.0 g/mol