No: pressure is not simply height times density. For a static fluid, the pressure increase with depth is height × density × gravitational acceleration, or ΔP = ρgh; the pressure at that depth also includes any pressure already acting on the fluid’s surface.
in h | Fluid-column height | m | 10 | 0
in rho | Fluid density | kg/m³ | 1000 | 0.001
in g | Gravitational acceleration | m/s² | 9.80665 | 0
out dp | Gauge pressure increase | Pa | rho * g * h | 0
out kpa | Gauge pressure increase | kPa | dp / 1000 | 3
Formula
The calculator finds the hydrostatic pressure increase across a stationary fluid column:
ΔP = ρgh
- ΔP is the pressure difference between the bottom and the top of the column, in pascals (Pa).
- ρ (rho) is the fluid’s mass density, in kilograms per cubic metre (kg/m³).
- g is gravitational acceleration, in metres per second squared (m/s²). The default is standard gravity, 9.80665 m/s².
- h is the vertical height or depth of the fluid column, in metres (m).
The units confirm why density times height alone is not pressure: (kg/m³) × m × (m/s²) = kg/(m·s²), which is a pascal. The calculator reports this increase as gauge pressure—the pressure above the pressure at the top of the column. It also gives the same increase in kilopascals, using 1 kPa = 1,000 Pa.
Worked Example
Using the calculator’s default values—10 m of water, density 1,000 kg/m³, and gravitational acceleration 9.80665 m/s²:
ΔP = ρgh
ΔP = (1,000 kg/m³)(9.80665 m/s²)(10 m)
ΔP = 98,066.5 Pa
ΔP = 98,066.5 Pa ÷ 1,000 = 98.067 kPa
Thus the pressure increase is 98,066.5 Pa, or 98.067 kPa. These results use the calculator’s displayed precision.
Assumptions
- The fluid is stationary and has a uniform density throughout the column.
- Height is measured vertically, not along a sloping pipe or surface.
- Gravity is constant over the height and equals the entered value; the default is standard gravity.
- The result is a pressure difference, not absolute pressure.
Why Height and Density Determine Hydrostatic Pressure
Pressure is force per unit area. In a fluid at rest, the material above a point exerts force on the material below it. A taller column contains more fluid weight above the point, while a denser fluid has more mass—and therefore more weight—in the same volume. Gravity converts that mass into weight. The combined effect is ρgh.
This relationship is often introduced as the hydrostatic pressure equation. It describes the pressure change with vertical depth in a fluid at rest, rather than every kind of pressure a fluid might exert. For a liquid open to the atmosphere, the pressure at the surface is atmospheric pressure, and pressure at depth is atmospheric pressure plus ρgh. For a sealed container, use the pressure at the fluid surface inside the container as the starting pressure.
For example, water’s density is approximately 1,000 kg/m³ under ordinary conditions. Each metre of water therefore adds roughly 9.8 kPa of pressure. This is a useful estimate, not a universal exact value: water density varies somewhat with temperature and composition.
Gauge Pressure, Absolute Pressure, and Depth
Gauge pressure measures pressure relative to the surrounding atmosphere. The calculator returns the pressure increase caused by the fluid column, so it is a gauge-pressure difference when the top is exposed to the atmosphere. Absolute pressure measures pressure relative to a vacuum.
To find absolute pressure at a point, add the pressure at the top of the column:
Pbottom = Ptop + ρgh
If the column is open to air, Ptop is local atmospheric pressure. At sea level, atmospheric pressure is commonly approximated as 101.325 kPa, but actual atmospheric pressure changes with weather and elevation. The calculator does not add atmospheric pressure because it calculates only the column’s pressure increase.
In a connected, stationary liquid, points at the same elevation have the same pressure if they are in the same continuous fluid and there are no intervening pressure sources or significant flow effects. The shape of the container does not change the pressure at a given depth: height, density, gravity, and surface pressure matter—not the container’s total width or volume.
Using the Formula for Different Fluids
To estimate the pressure increase in another fluid, enter its density in kg/m³ and the vertical column height in metres. Density is a property of the particular fluid and its conditions, so do not assume that every liquid has water’s density. A denser liquid produces a greater pressure increase at the same height.
For instance, if a fluid has density 800 kg/m³ and forms a 5 m vertical column under standard gravity, the pressure increase is (800)(9.80665)(5) = 39,226.6 Pa, or about 39.227 kPa. This example illustrates the calculation; it is not a claim that 800 kg/m³ applies to every fluid of a particular type.
For a fluid whose density changes significantly with height, one constant density is not enough for an exact result. The more general relationship is dP = ρg dh; the pressure change is found by integrating density times gravity over the vertical distance. In a layered liquid, calculate each layer’s contribution, ρᵢghᵢ, and add the pressure differences, provided each layer is stationary and its density is reasonably uniform.
Common Errors and Limits
- Leaving out gravity: ρh has units of mass per area, not pressure. Multiply by g to obtain pascals.
- Mixing units: use metres, kg/m³, and m/s² together. Convert centimetres to metres by dividing by 100; convert a density given in g/cm³ to kg/m³ by multiplying by 1,000.
- Using path length instead of vertical depth: a slanted column’s length is not its hydrostatic height. Use the vertical difference in elevation.
- Confusing pressure increase with total pressure: add the pressure acting at the top when absolute or total pressure is needed.
- Applying a static-fluid equation to flowing systems: pumps, flow speed, friction, and elevation changes can affect pressures in pipes. ΔP = ρgh alone does not account for these effects.
The equation is appropriate for a fluid at rest, or as the hydrostatic component of a more complete analysis. It does not by itself determine structural loads, pressure losses in a moving fluid, or the pressure distribution in a fluid with substantial density variation.
Frequently Asked Questions
Is pressure equal to height times density?
No. Height times density is missing gravitational acceleration. The hydrostatic pressure increase is ΔP = ρgh.
What is the pressure formula for liquid at depth?
The increase above the surface pressure is ρgh. For absolute pressure, add the pressure at the surface: P = Psurface + ρgh.
How much pressure does one metre of water add?
Using a density of 1,000 kg/m³ and standard gravity, one metre adds 9,806.65 Pa, or about 9.807 kPa. The precise value varies with water density and gravity.
Does container shape affect pressure at the bottom?
Not in a stationary fluid when the vertical depth, density, gravity, and surface pressure are the same. Container shape affects the amount of fluid, but not this hydrostatic pressure relationship.
Is hydrostatic pressure gauge or absolute pressure?
ρgh gives the pressure difference due to the fluid column. It is the gauge pressure increase relative to the pressure at the top; add the top pressure to obtain absolute pressure.
Related
General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.
More in this section
- Heat Gain and Loss Calculator for Calorimetry4,184.00 J
- Heat Output Calculator kW: Estimate Thermal Power1.395 kW
- Heat Calculation: Formula, Example, and Limits41,840 J
- Heat Energy Released Formula and Worked Example23,012 J
- Heat Transfer Equation for q: Formula and Examples41,840 J
- Heat Rate Formula: Calculate Energy per Unit Time166.67 W