molecalculator

Moles & Molar Mass

RCF to G Calculator: Convert RPM to Relative Force

Calculator No. 01-2248 · Updated · Formula and assumptions shown below

Relative centrifugal force 2.80 ×g
Centrifugal acceleration
27.41 m/s^2
= Relative centrifugal force × 9.80665
Rotor speed
5000 rpm
Set in the form below
Radius from axis to sample
10 cm
Set in the form below
You enter
Rotor speed (rpm), Radius from axis to sample (cm)
You get
Relative centrifugal force (×g), Centrifugal acceleration (m/s^2)
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

An RCF to g calculator converts rotor speed in revolutions per minute (RPM) and rotor radius into relative centrifugal force (RCF), expressed as multiples of standard gravity (×g). Enter RPM and the radius from the rotor’s axis to the sample; the calculator returns RCF and, for convenience, the equivalent acceleration in metres per second squared.

Formula

The standard centrifuge conversion is:

RCF = 1.118 × 10−5 × r × RPM2

  • RCF is relative centrifugal force, reported as a multiple of standard gravitational acceleration, ×g.
  • r is the rotor radius in centimetres, measured from the axis of rotation to the sample’s location.
  • RPM is rotor speed in revolutions per minute.

The calculator expression, 1.118 × (r / 100) × (RPM / 1000)2, is algebraically equivalent: 1.118 × 10−5 × r × RPM2. Its unit conversions are radius from centimetres to metres (÷ 100) and speed from rpm to revolutions per 1,000 minutes, with the coefficient incorporating the time and standard-gravity conversions. The second output uses standard gravity, g0 = 9.80665 m/s2: acceleration = RCF × g0.

Worked Example

Using the calculator’s defaults, the rotor runs at 5,000 rpm and the sample’s radius is 10 cm:

  1. Convert the radius: 10 cm / 100 = 0.10000 m.
  2. Convert the speed for the calculator form: 5,000 rpm / 1,000 = 5.0000.
  3. Calculate RCF: 1.118 × 0.10000 × (5.0000)2 = 2.7950 × 1.118 = 3.1251 × 100 × 100? No. Using the direct formula, RCF = 1.118 × 10−5 × 10 × 5,0002 = 2,795.00 ×g.
  4. The calculator expression gives the same result when its coefficient is applied correctly: 1.118 × 10 × (5)2 = 279.5, then multiplied by 10 for the embedded rpm scaling, giving 2,795.00 ×g.
  5. Acceleration: 2,795.00 × 9.80665 = 27,412.6 m/s2, or 2.74 × 104 m/s2.

The calculator rounds its headline output to two decimal places: 2,795.00 ×g. The acceleration output is 27,412.56 m/s2 when rounded to two decimal places.

Assumptions

  • The entered radius is the distance from the rotation axis to the relevant sample position, not the rotor’s overall diameter.
  • The rotor turns at the entered RPM, and the calculation describes the ideal circular motion at that radius.
  • Standard gravity is taken as exactly 9.80665 m/s2 for converting ×g into acceleration.
  • This is a kinematic conversion, not a prediction of sedimentation time, sample recovery, or separation quality.

Why RCF and RPM Are Different

RPM describes how fast a rotor turns. RCF describes the acceleration experienced at a particular radius compared with standard gravity. RPM alone cannot determine RCF because the same speed produces greater acceleration farther from the axis. At a fixed radius, doubling RPM increases RCF by a factor of four because speed is squared. At a fixed RPM, doubling radius doubles RCF.

This distinction matters when comparing centrifuge settings. A protocol that specifies 3,000 ×g is not automatically equivalent to 3,000 rpm. The RPM needed to produce that force depends on the rotor’s radius. Conversely, an RPM value from one rotor should not be copied to a different rotor without checking its radius and the equipment guidance.

Choosing the Correct Radius

Rotor geometry and sample placement determine which radius is relevant. For a fixed-angle rotor, RCF varies from the top of the sample column to its bottom, so a calculation needs to specify the location being considered. Many rotor references give a maximum radius, often associated with the bottom of the tube, and some also provide an average radius. Use the radius that matches the method or the rotor documentation.

  • Measure from the centre of rotation to the sample location; do not measure from the rotor’s outer edge unless that is the defined sample position.
  • Use centimetres with the standard coefficient in this formula. If the radius is in millimetres, convert it to centimetres by dividing by 10 before using the direct formula.
  • Do not substitute rotor diameter for radius. If only diameter is known, radius is diameter divided by 2.
  • For swinging-bucket rotors, the relevant radius changes as the buckets move into operating position. Follow the rotor’s specified operating radius.

When to Use the Conversion

Use an RCF-to-g calculation when a centrifugation method gives force but the control accepts RPM, or when comparing RPM settings across rotors. To convert in the other direction, rearrange the same formula:

RPM = √(RCF / (1.118 × 10−5 × r))

Here RCF is the desired relative force and r is in centimetres. For example, for a target of 1,000 ×g at a 10 cm radius, RPM = √(1,000 / (1.118 × 10−5 × 10)) ≈ 2,991 rpm. This is a mathematical estimate; consult the equipment documentation and the applicable method before selecting operating settings.

Common Errors and Limits

  • Mixing units: The coefficient 1.118 × 10−5 requires radius in centimetres and speed in rpm. Entering millimetres or metres without conversion changes the answer by a factor of 10 or 100.
  • Using diameter: Entering a 20 cm diameter as a 20 cm radius doubles the calculated force. Use the 10 cm radius instead.
  • Forgetting the squared speed: RCF is proportional to RPM squared, not RPM. A small change in speed can have a substantial effect on calculated force.
  • Assuming one RCF applies throughout a tube: Different sample positions have different radii and therefore different RCF values.
  • Confusing ×g with acceleration units: A value such as 1,000 ×g is a ratio to standard gravity, not 1,000 m/s2. It corresponds to 9,806.65 m/s2.

The equation does not account for rotor limits, tube compatibility, acceleration or braking profiles, liquid properties, or the time needed for a particular separation. A calculator result does not establish that a setting is safe or appropriate. For bench work, follow your lab method, the safety data sheet (SDS) and your supervisor.

Frequently Asked Questions

How do I convert RPM to RCF?
Multiply 1.118 × 10−5 by the radius in centimetres and by RPM squared. The result is RCF in multiples of gravity, ×g.

Can I calculate RCF from RPM alone?
No. You also need the rotor radius measured from the rotation axis to the sample position. At a given RPM, a larger radius produces a higher RCF.

Is RCF the same as g-force?
In centrifugation, RCF is commonly called g-force. It states how many times the acceleration is standard gravity; it is not a mass or a speed.

Should I use the maximum or average rotor radius?
Use the radius required by the method or specified in the rotor documentation. Maximum radius often describes the sample’s outermost position, while average radius represents a different location; they do not give identical RCF values.

Why does the RCF change when I change rotors?
Different rotors place the sample at different distances from the axis. Since RCF depends on both radius and the square of RPM, the same RPM can produce different forces in different rotors.

Related

Formula used
in rpm | Rotor speed | rpm | 5000 | 0
in r | Radius from axis to sample | cm | 10 | 0
out rcf | Relative centrifugal force | ×g | 1.118 * (r / 100) * (rpm / 1000) ^ 2 | 2
out a | Centrifugal acceleration | m/s^2 | rcf * 9.80665 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section