Series LC Resonance Calculator: Frequency & More

Calculator No. 01-11642 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

A series LC resonance calculator works out the resonant frequency of a circuit made of an inductor and a capacitor connected in series, along with the related reactances and impedance at that frequency. You enter the inductance in henries and the capacitance in farads, and the calculator returns the resonant frequency in hertz, plus the inductive and capacitive reactances and the quality factor if a resistance is included. The resonant frequency is the natural frequency at which the stored energy oscillates between the magnetic field of the inductor and the electric field of the capacitor.

Formula

The resonant frequency of a series LC circuit is given by:

fr = 1 / (2π √(L × C))

  • fr = resonant frequency in hertz (Hz)
  • L = inductance in henries (H)
  • C = capacitance in farads (F)

At resonance, the inductive reactance XL = 2πfL and the capacitive reactance XC = 1/(2πfC) are equal in magnitude, so they cancel each other in a series circuit. The impedance is purely resistive and equals the series resistance R. The quality factor Q = XL/R (or XC/R) measures how sharp the resonance is.

Worked Example

Using the default values from the calculator: L = 0.0001 H (100 µH) and C = 0.0000000001 F (100 pF).

  1. Compute the product LC = 0.0001 × 0.0000000001 = 1 × 10−14 H·F.
  2. Take the square root: √(1 × 10−14) = 1 × 10−7.
  3. Multiply by 2π: 2π × 1 × 10−7 ≈ 6.283185 × 10−7.
  4. Take the reciprocal: 1 / (6.283185 × 10−7) ≈ 1,591,549 Hz.

So the resonant frequency is approximately 1.592 × 106 Hz (1.592 MHz). The calculator rounds to 3 decimals, giving 1591549.430 Hz. The inductive reactance at resonance is 2π × 1.592×106 × 0.0001 ≈ 1000 Ω, and the capacitive reactance is the same. With R = 10 Ω, Q = 1000 / 10 = 100.

Assumptions

  • The inductor and capacitor are ideal: no parasitic resistance, capacitance, or inductance.
  • The circuit is linear and time-invariant.
  • The formula holds for any frequency, but real components have self-resonant frequencies where they stop behaving ideally.
  • The calculator assumes a simple series connection; parallel resonance uses a different formula.

How a Series LC Circuit Works

In a series LC circuit, the inductor and capacitor are connected end-to-end. At low frequencies, the capacitor has high reactance and dominates, so the circuit behaves capacitively. At high frequencies, the inductor’s reactance dominates. At the resonant frequency, the reactances are equal and opposite, so they cancel. The impedance is minimum and equals the series resistance. This is why series LC circuits are used as band-pass filters: they pass signals near resonance and attenuate others.

The energy oscillates between the magnetic field of the inductor and the electric field of the capacitor. If there is no resistance, the oscillation continues forever; in practice, resistance dissipates energy as heat, causing the amplitude to decay.

Choosing Component Values

When designing a resonant circuit, you usually know the target frequency and one component value, then solve for the other. Rearranging the formula:

  • If you have a fixed inductor, C = 1 / (4π² f² L).
  • If you have a fixed capacitor, L = 1 / (4π² f² C).

For example, to get 1 MHz with a 100 µH inductor, C = 1 / (4π² × (106)² × 10−4) ≈ 2.533 × 10−10 F (253 pF).

Component tolerances matter: a 5% capacitor and a 10% inductor can shift the actual resonance by several percent. Use precision components if the frequency must be exact.

Common Mistakes and Misconceptions

  • Unit mix-ups: Forgetting to convert millihenries (mH) and microfarads (µF) to henries and farads. 1 mH = 10−3 H, 1 µF = 10−6 F, 1 pF = 10−12 F.
  • Confusing series and parallel resonance: Parallel LC circuits have a different resonant frequency formula (same formula for ideal components, but the impedance is maximum instead of minimum).
  • Ignoring resistance: Real inductors have wire resistance, which lowers the Q and broadens the resonance peak.
  • Assuming the formula gives the exact frequency: The formula is for ideal components; parasitic capacitance and inductance shift the actual resonance.

Quality Factor and Bandwidth

The quality factor Q is a key parameter. For a series RLC circuit, Q = XL/R at resonance. A high Q means a narrow bandwidth and a sharp peak. The bandwidth (BW) is fr/Q. For example, with fr = 1.592 MHz and Q = 100, the bandwidth is 15.92 kHz. This is the range of frequencies where the power is at least half the peak value (−3 dB points).

To increase Q, reduce the series resistance (use thicker wire, better components) or increase the ratio of reactance to resistance.

Practical Applications

Series LC circuits are used in:

  • Radio receivers and transmitters for tuning to a specific frequency.
  • Filters in audio electronics to remove unwanted frequencies.
  • Oscillators where the LC tank sets the frequency.
  • Impedance matching networks.

Limitations of the Formula

The simple formula assumes ideal components. Real inductors have parasitic capacitance between windings, and real capacitors have equivalent series resistance (ESR) and inductance (ESL). At very high frequencies (above about 100 MHz), these parasitics dominate and the circuit no longer behaves as a simple LC. Also, the formula does not account for temperature effects or component aging. For precision work, measure the actual resonance with a network analyzer or oscilloscope.

Frequently Asked Questions

What is the difference between series and parallel resonance?

In a series LC circuit, the impedance is minimum at resonance (ideally zero plus resistance). In a parallel LC circuit, the impedance is maximum at resonance. The resonant frequency formula is the same for ideal components, but the behavior of the circuit at resonance is opposite. Series resonance is used for band-pass filters, while parallel resonance is used for band-stop (notch) filters.

How do I convert microhenries and picofarads to henries and farads?

1 microhenry (µH) = 10−6 H. 1 picofarad (pF) = 10−12 F. So 100 µH = 100 × 10−6 H = 1 × 10−4 H, and 100 pF = 100 × 10−12 F = 1 × 10−10 F. Always convert to base units before using the formula.

Why does my measured resonant frequency differ from the calculated one?

Real components have tolerances (typically ±5% for capacitors, ±10% for inductors). Also, the inductor has parasitic capacitance and the capacitor has parasitic inductance, which shift the actual resonance. The formula gives the ideal value; measure the actual components if precision is needed.

Can I use this calculator for parallel LC circuits?

The resonant frequency formula is the same for ideal parallel LC circuits, but the impedance behavior is different. This calculator is designed for series circuits; for parallel circuits, the same frequency result applies but the Q and bandwidth calculations differ.

What is the significance of the quality factor (Q)?

Q indicates how underdamped the circuit is. A high Q means the circuit resonates sharply at one frequency and rejects others quickly; a low Q means a broader response. In filters, a high Q gives better selectivity. In oscillators, a high Q improves frequency stability.

Related

Formula used
in L | Inductance | H | 0.0001 | 1e-12 | 10
in C | Capacitance | F | 0.0000000001 | 1e-15 | 1
in R | Series resistance | ohm | 10 | 0.001 | 1000000
out f | Resonant frequency | Hz | 1 / (2 * pi * sqrt(L * C)) | 3
out XL | Inductive reactance at f | ohm | 2 * pi * f * L | 2
out XC | Capacitive reactance at f | ohm | 1 / (2 * pi * f * C) | 2
out Q | Quality factor | - | XL / R | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.