molecalculator

Moles & Molar Mass

Temperature Humidity Index Calculator

Calculator No. 01-13406 · Updated · Formula and assumptions shown below

Temperature Humidity Index 79.8
Comfort category
1
= 1
Air temperature
30 °C
Set in the form below
Relative humidity
60 %
Set in the form below
You enter
Air temperature (°C), Relative humidity (%)
You get
Temperature Humidity Index, Comfort category
Rounding
1 dp · 0 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The Temperature Humidity Index (THI) calculator works out a single comfort/stress number from air temperature and relative humidity, and that number tells you how hot it feels to humans or livestock. You enter the dry-bulb temperature (in °C or °F) and the relative humidity (in %), and you get back the THI value plus a plain-language comfort category (e.g., “comfortable” or “danger”). The index is widely used in agriculture and weather services to warn about heat stress before the thermometer alone would suggest a problem.

Formula

The most common THI formula (the one used by many national weather services and agricultural extension offices) is:

THI = 0.8 × T + (RH/100) × (T − 14.4) + 46.4

  • T = air temperature in °C
  • RH = relative humidity in % (0 to 100)

All temperatures are in degrees Celsius. If you have Fahrenheit, convert first: °C = (°F − 32) × 5/9. The formula is an empirical fit, not a physical law; it was developed in the 1950s for cattle and later adapted for human comfort. It combines the dry-bulb temperature and humidity into a single “apparent temperature” that correlates with heat stress responses.

Worked Example

Using the default values from the calculator: T = 30 °C, RH = 60%.

  1. Compute the humidity fraction: 60/100 = 0.6
  2. Compute the temperature difference: 30 − 14.4 = 15.6
  3. Multiply: 0.6 × 15.6 = 9.36
  4. Multiply the temperature term: 0.8 × 30 = 24.0
  5. Add everything: 24.0 + 9.36 + 46.4 = 79.76

Rounded to one decimal, the THI is 79.8. The calculator shows the same result. For humans, a THI of 79.8 falls in the “caution” zone (most people feel hot and uncomfortable). For dairy cattle, it is already in the “mild stress” range.

Assumptions

  • The formula assumes a standard air pressure (sea level roughly) and still air (no wind). Wind and solar radiation are not included.
  • Relative humidity is the true relative humidity, not dew point or specific humidity.
  • The index is a statistical correlation, not a direct measure of body heat load; individual responses vary.
  • For livestock, the formula is calibrated for cattle; other species (poultry, pigs) have different thresholds.

How to Read the Result

THI values are usually grouped into comfort/stress categories. For humans, a common scale is:

  • Below 70 – comfortable for most people
  • 70–75 – slightly warm; some discomfort
  • 75–80 – caution; heat exhaustion possible with prolonged exposure
  • 80–85 – danger; heat cramps and exhaustion likely
  • Above 85 – extreme danger; heat stroke possible

For livestock (especially dairy cows), the thresholds are lower because animals have less efficient cooling. For example, a THI above 72 is often considered the start of mild heat stress in high-producing dairy cows, and above 80 is severe stress. The same calculator works for both; just adjust the interpretation scale.

Common Mistakes and Limitations

The most frequent error is mixing units: the formula is only valid for Celsius. If you enter a Fahrenheit temperature without converting, the THI will be wildly wrong (e.g., 90 °F would give a THI of about 118, which is impossible). Always convert to °C first.

Another mistake is using dew point or wet-bulb temperature directly. The formula needs relative humidity, not dew point. If you only have dew point, you must compute RH first (which itself depends on temperature).

Limitations: the THI ignores wind speed, solar radiation, and clothing. A hot, humid, still day feels worse than a hot, humid, breezy day, but both give the same THI. It also assumes the air is well-mixed and that the person/animal is acclimated; a person from a cool climate will feel stress at lower THI than a local resident.

Why Use THI Instead of Just Temperature?

Your body cools itself by evaporating sweat. When humidity is high, sweat evaporates more slowly, so the same temperature feels hotter. The THI captures that effect. For example, 30 °C with 30% RH gives a THI of about 71 (comfortable), but 30 °C with 90% RH gives a THI of about 84 (danger). The thermometer alone would not show that difference.

In agriculture, THI is used to decide when to turn on cooling fans, sprinklers, or shade for livestock. In public health, it is used to issue heat warnings. The index is simple enough to compute by hand, but a calculator is convenient when you have many data points or need to check quickly.

Alternatives to THI

Several other indices exist, each with a different focus:

  • Heat Index (HI) – used by the U.S. National Weather Service; similar in purpose but uses a more complex polynomial and is calibrated for humans in the shade.
  • Humidex – used in Canada; combines temperature and dew point, not relative humidity.
  • Wet-Bulb Globe Temperature (WBGT) – includes solar radiation and wind; used for military and athletic heat stress standards.
  • Apparent Temperature – used in Australia; includes wind and humidity.

THI is the simplest and most widely used for livestock. For human heat warnings, the Heat Index or Humidex may be more familiar, but the THI still gives a reasonable approximation and is easier to compute.

How to Use the Calculator

Enter the current air temperature (in °C) and the relative humidity (in %). The calculator returns the THI value and a comfort category. The category is a simple lookup based on the THI value, using the human scale above. If you are working with livestock, ignore the category and use the animal-specific thresholds.

For example, if you are a dairy farmer checking the barn at 8 a.m., you might enter 22 °C and 85% RH. The THI would be about 72, which is borderline for cows. That tells you to start fans earlier than you would if you only looked at the temperature.

Frequently Asked Questions

What is the difference between THI and Heat Index?
The Heat Index (HI) is a more detailed human comfort index that uses a complex regression equation, while THI is a simpler linear formula. Both use temperature and humidity, but HI is calibrated for human physiology in the shade with light wind. THI is often used for livestock and is easier to compute manually.

Can I use THI for pets like dogs or cats?
Dogs and cats cool mostly by panting, not sweating, so THI is not directly applicable. For pets, a better guide is the ambient temperature plus humidity, but you should also consider the surface temperature (pavement can burn paws) and the animal’s breed. Consult a veterinarian for specific heat safety thresholds.

Why does my weather app show a different “feels like” temperature than this calculator?
Weather apps often use the Heat Index, Humidex, or a proprietary apparent temperature that includes wind and solar radiation. THI is one of many indices; each gives a slightly different number because they use different formulas and inputs. The THI here is the classic agricultural formula, not the same as the Heat Index.

What is the highest possible THI?
Theoretically, if temperature is 60 °C and RH is 100%, THI would be about 0.8×60 + 1.0×(60−14.4) + 46.4 = 140. But such conditions are not survivable for long. In practice, THI values above 90 are already extreme and rare; the calculator’s input limits (temperature up to 60 °C, RH up to 100%) cover all realistic weather.

Does wind affect THI?
No, the classic THI formula ignores wind. Wind can make a hot day feel cooler by speeding up evaporation, so the actual heat stress may be lower than the THI suggests. For a wind-adjusted index, use the Wet-Bulb Globe Temperature (WBGT) or the Heat Index with wind correction.

Related

Formula used
in t | Air temperature | °C | 30 | -40 | 60
in rh | Relative humidity | % | 60 | 0 | 100
out thi | Temperature Humidity Index | - | 0.8 * t + rh / 100 * (t - 14.4) + 46.4 | 1
out cat | Comfort category | - | 1 | 0

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section