The thermal conductivity formula k = Q·L / (A·ΔT·t) has the dimension M·L·T−3·θ−1 (mass × length × time−3 × temperature−1), which in SI units is watts per meter-kelvin (W·m−1·K−1). This page explains the dimensional derivation, how to use the formula in heat-transfer calculations, and common unit pitfalls.
Formula
Fourier’s law of heat conduction gives the rate of heat transfer through a flat slab of material:
Q / t = k · A · (ΔT / L)
Solving for the thermal conductivity k:
k = Q · L / (A · ΔT · t)
- Q – heat energy transferred (joules, J)
- t – time over which the heat flows (seconds, s)
- A – cross-sectional area perpendicular to heat flow (square meters, m²)
- ΔT – temperature difference between the hot and cold faces (kelvin, K; a difference in °C is numerically identical)
- L – thickness of the material along the heat-flow path (meters, m)
The result k is the thermal conductivity, measured in watts per meter-kelvin (W·m−1·K−1).
Worked Example
Using the default values from the calculator:
- Q = 1500 J
- L = 0.02 m
- A = 0.1 m²
- ΔT = 30 K
- t = 60 s
Substitute into the formula:
k = (1500 J × 0.02 m) / (0.1 m² × 30 K × 60 s)
k = 30 J·m / (180 m²·K·s)
k = 0.1667 J·m / (m²·K·s)
Since 1 J/s = 1 W, the units simplify to W·m−1·K−1:
k ≈ 0.167 W·m−1·K−1
This is close to the thermal conductivity of common insulating materials (e.g., fiberglass ~0.04, wood ~0.12–0.15, water ~0.6 W·m−1·K−1).
Assumptions
- Steady-state heat flow: temperatures on each face remain constant.
- One-dimensional conduction: heat flows only perpendicular to the faces.
- Uniform material: k is constant throughout the slab.
- No heat loss from the edges or by radiation/convection.
- The material is homogeneous and isotropic (same properties in all directions).
Dimensional Derivation
To find the dimension of k, we write the formula in terms of base quantities: mass (M), length (L), time (T), and temperature (θ).
- Heat Q is energy: dimension M·L²·T−2.
- Thickness L: dimension L.
- Area A: dimension L².
- Temperature difference ΔT: dimension θ.
- Time t: dimension T.
Substitute into k = Q·L / (A·ΔT·t):
[k] = (M·L²·T−2 · L) / (L² · θ · T)
[k] = M·L³·T−2 / (L²·θ·T)
[k] = M·L·T−3·θ−1
This is the dimensional formula. In SI, the base units are kg·m·s−3·K−1, which is equivalent to W·m−1·K−1 because 1 W = 1 kg·m²·s−3.
Why the Units Matter
Thermal conductivity values are always quoted with their units, and mixing unit systems is the most common error. For example, if you measure heat in calories, thickness in centimeters, area in cm², and temperature in °C, you get a result in cal·cm−1·s−1·°C−1 – which is a different number from the SI value. To convert, use 1 cal = 4.184 J and 1 cm = 0.01 m. The conversion factor for conductivity is 1 cal·cm−1·s−1·°C−1 = 418.4 W·m−1·K−1.
Another common mistake is using Celsius instead of kelvin for ΔT. Since a temperature difference of 1 °C equals a difference of 1 K, this does not change the numerical value – but it is good practice to write K.
Also, be careful with area units. If you measure area in cm², convert to m² (divide by 10,000) before using the SI formula, or your k will be off by a factor of 104.
How to Use the Calculator
Enter the heat energy transferred through the material, the thickness of the slab, the cross-sectional area, the temperature difference between the two faces, and the time over which the heat flows. The calculator returns the thermal conductivity in W·m−1·K−1.
This is useful in several practical situations:
- Identifying an unknown material by measuring its conductivity and comparing with reference tables.
- Checking whether a material meets insulation specifications.
- Estimating heat loss through a wall or window if you know the conductivity.
- Verifying a manufacturer’s claimed k value in a simple lab setup.
The calculator assumes steady-state conduction and no edge losses, so your measured result may differ from the true value if those conditions are not met.
Limits of the Formula
Fourier’s law is a linear approximation. It works well for most solids and fluids over moderate temperature ranges, but it fails when:
- The material is anisotropic (e.g., wood, composites) – the formula gives an average value.
- Temperature changes are large enough to change k itself.
- Heat transfer is not purely conductive (e.g., in gases where convection is present).
- The material is not homogeneous – voids or layers create contact resistance.
For insulators like still air (k ≈ 0.026 W·m−1·K−1) the formula is accurate only if convection is suppressed. For metals like copper (k ≈ 400 W·m−1·K−1), the formula works well for thin slabs and moderate gradients.
Comparison with Thermal Resistance
A related quantity is thermal resistance R, defined as L / (k·A) for a slab. Its SI unit is K·W−1. The reciprocal of thermal resistance is thermal conductance. In building engineering, the R-value (in m²·K·W−1) is simply L / k per unit area. Knowing k lets you compute R-values, which are used to compare insulation performance.
Frequently Asked Questions
What is the dimensional formula of thermal conductivity?
The dimensional formula is M·L·T−3·θ−1, which in SI is kg·m·s−3·K−1, equivalent to W·m−1·K−1.
Is thermal conductivity the same as heat transfer coefficient?
No. Thermal conductivity k is a material property (W·m−1·K−1). The heat transfer coefficient h (W·m−2·K−1) describes convection or combined effects at a surface, and depends on geometry and fluid flow, not just the material.
Why is thermal conductivity often given in W/m·K and not in SI base units?
W/m·K is the coherent derived SI unit. It is more practical than kg·m·s−3·K−1 because watts and meters are familiar in engineering. Both represent the same dimension.
Does thermal conductivity change with temperature?
Yes. For most materials, k varies with temperature. Metals typically decrease slightly with increasing temperature, while insulators and gases increase. The formula assumes a constant k, so for large temperature differences you should use the average value over the range.
Can I use this formula for liquids and gases?
Yes, but only for pure conduction. In fluids, natural convection often dominates, so the measured effective conductivity can be higher. The formula is most reliable for solids and for thin fluid layers where convection is suppressed.
What is the difference between thermal conductivity and thermal diffusivity?
Thermal diffusivity (α = k / (ρ·cp)) measures how quickly temperature changes propagate through a material. It has units of m²·s−1. Conductivity measures the rate of heat flow per unit gradient, not the speed of temperature change.
Related
Formula used
in q | Heat transferred | J | 1500 | 0 in l | Thickness of material | m | 0.02 | 0 in a | Cross-sectional area | m² | 0.1 | 0 in dt | Temperature difference (hot – cold) | K | 30 | 0 in t | Time of heat flow | s | 60 | 0 out k | Thermal conductivity | W/(m·K) | q * l / (a * dt * t) | 3
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- QPP Calculator Canada: How It Works & How to Use It
- PPP Calculator World Bank: How It Works & How to Use It2,000.00
- PPP Calculator: India vs USA Cost Comparison1,000.00 USD
- PPP Calculator USD to INR: How It Works2,335 INR
- PPP Calculator India vs UK: Real Cost Comparison103.63 GBP
- PPP Calculator India vs Dubai: Real Cost Comparison8,954.58 AED