This calculator converts thermal conductivity values between the most common units: W/(m·K), W/(m·°C), W/(cm·°C), kW/(m·K), cal/(s·cm·°C), and BTU/(h·ft·°F). You enter a numeric value and select its unit, and the calculator returns the equivalent in all other units, so you can compare data from different sources or check your own measurements.
Formula
Thermal conductivity (k) measures how well a material conducts heat. The SI unit is watts per meter-kelvin, W/(m·K). Because a temperature difference of 1 K equals a difference of 1 °C, W/(m·K) and W/(m·°C) are numerically identical. The conversion factors are:
- 1 W/(cm·°C) = 100 W/(m·K) (since 1 cm = 0.01 m)
- 1 kW/(m·K) = 1000 W/(m·K)
- 1 cal/(s·cm·°C) = 418.68 W/(m·K) (using the thermochemical calorie: 1 cal = 4.184 J)
- 1 BTU/(h·ft·°F) = 1.730735 W/(m·K) (1 BTU = 1055.056 J, 1 h = 3600 s, 1 ft = 0.3048 m, 1 °F = 5/9 K)
The calculator first converts the input value to W/(m·K) using the selected factor, then divides by the factor for each target unit.
Worked Example
Suppose you have a material with thermal conductivity 0.6 W/(m·K) (close to that of brick or glass). Using the default input value 0.6 and unit W/(m·K):
- Convert to W/(m·K): 0.6 × 1 = 0.6 W/(m·K).
- To W/(cm·°C): 0.6 / 100 = 0.006 W/(cm·°C).
- To kW/(m·K): 0.6 / 1000 = 0.0006 kW/(m·K).
- To cal/(s·cm·°C): 0.6 / 418.68 ≈ 0.001433 cal/(s·cm·°C).
- To BTU/(h·ft·°F): 0.6 / 1.730735 ≈ 0.3467 BTU/(h·ft·°F).
The calculator shows 0.6 W/(m·K), 0.6 W/(m·°C), 0.006 W/(cm·°C), 0.0006 kW/(m·K), 0.0014 cal/(s·cm·°C), and 0.3467 BTU/(h·ft·°F).
Assumptions
- All conversions use the thermochemical calorie (1 cal = 4.184 J), not the International Steam Table calorie (4.1868 J). The difference is about 0.07%.
- The conversion between °C and K is a difference conversion: 1 °C change = 1 K change, so no offset is needed.
- The BTU is the International Table BTU (1 BTU = 1055.056 J).
Why Unit Conversion Matters
Thermal conductivity values appear in many forms. Scientific papers often use SI units (W/(m·K)), but engineering handbooks in the US may list BTU/(h·ft·°F), and older literature or polymer data sheets sometimes use cal/(s·cm·°C). If you are comparing materials for insulation, electronics cooling, or heat exchanger design, mixing units can lead to errors of orders of magnitude. For example, a value of 0.5 W/(m·K) is a decent insulator, but 0.5 BTU/(h·ft·°F) is actually about 0.865 W/(m·K) – a significant difference.
How to Use the Calculator
Enter the numeric thermal conductivity value in the first field. Then select the unit of that value from the dropdown. The calculator immediately shows the equivalent in all other units. For example, if you have a value of 1.2 cal/(s·cm·°C) (typical for silver), select that unit and you will see it equals about 502.4 W/(m·K).
Common mistakes:
- Forgetting that W/(m·K) and W/(m·°C) are the same number – they are, because a kelvin and a degree Celsius are the same size.
- Using the wrong calorie (thermochemical vs. IT) – the difference is small but can matter in precise work.
- Confusing W/(cm·°C) with W/(m·K) – the former is 100 times larger.
Limits of the Calculator
This calculator only converts units. It does not account for the fact that thermal conductivity varies with temperature, pressure, or material purity. For example, the thermal conductivity of copper is about 401 W/(m·K) at 20 °C but drops to about 385 W/(m·K) at 500 °C. Always use values measured at the temperature relevant to your application. Also, some materials are anisotropic – their conductivity differs along different axes (e.g., graphite). The calculator assumes a single scalar value.
Frequently Asked Questions
Is W/(m·K) the same as W/(m·°C)?
Yes, numerically they are identical because a temperature difference of 1 kelvin equals a difference of 1 degree Celsius. The unit W/(m·°C) is sometimes used in engineering, but W/(m·K) is the SI standard.
How do I convert BTU/(h·ft·°F) to W/(m·K)?
Multiply the BTU value by 1.730735. For example, 10 BTU/(h·ft·°F) ≈ 17.31 W/(m·K).
What is a typical thermal conductivity for common materials?
Air is about 0.026 W/(m·K) at room temperature, water about 0.6 W/(m·K), glass about 1.0 W/(m·K), and metals range from about 15 (stainless steel) to 400 (copper) W/(m·K).
Can I use this calculator for thermal resistance or U-values?
No, thermal resistance (K·m²/W) and U-values (W/(m²·K)) are different quantities. This calculator only converts thermal conductivity (W/(m·K)).
Why do some data sheets use cal/(s·cm·°C)?
This unit was common in older literature and in some polymer or ceramic data sheets, especially those following CGS conventions. It is still encountered, so having a conversion tool is useful.
Does the calculator handle negative values?
Thermal conductivity is always positive for real materials. The calculator allows zero (for a perfect vacuum, which conducts no heat) but not negative values.
Related
Formula used
in val | Thermal conductivity value | - | 0.6 | 0 | 1000000 sel uin | Input unit | W/(m·K)=1, W/(m·°C)=1, W/(cm·°C)=100, kW/(m·K)=1000, cal/(s·cm·°C)=418.68, BTU/(h·ft·°F)=1.730735 out wmk | Value in W/(m·K) | W/(m·K) | val * uin | 4 out wmc | Value in W/(m·°C) | W/(m·°C) | wmk | 4 out wcm | Value in W/(cm·°C) | W/(cm·°C) | wmk / 100 | 4 out kwmk | Value in kW/(m·K) | kW/(m·K) | wmk / 1000 | 4 out cal | Value in cal/(s·cm·°C) | cal/(s·cm·°C) | wmk / 418.68 | 4 out btu | Value in BTU/(h·ft·°F) | BTU/(h·ft·°F) | wmk / 1.730735 | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- ug to ppb Calculator: Convert Micrograms per Liter1.00 ppb
- Grams to Moles Chemistry: How to Convert0.2000 mol/L
- Convert ug/l to ppb Calculator
- CPP Calculator Ontario: How CPP Is Calculated162.12 $/month
- Grams to Moles to Molecules: How to Convert0.2000 mol/L
- Organic Chemistry Reaction Calculator: How It Works