molecalculator

Moles & Molar Mass

Thermal Expansion Calculator Concrete: How to Use

Calculator No. 01-8871 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This thermal expansion calculator for concrete tells you how much a concrete member will expand or contract when its temperature changes. You enter the original length, the temperature change, and the coefficient of thermal expansion (CTE) for your concrete mix; the calculator returns the change in length in millimeters or inches. It uses the standard linear expansion formula ΔL = α × L₀ × ΔT, and the result helps you plan expansion joints, estimate movement in large slabs, and avoid stress-related cracking.

Formula

The linear thermal expansion formula is:

ΔL = α × L₀ × ΔT

  • ΔL = change in length (mm or inches)
  • α = coefficient of linear thermal expansion (1/°C or 10⁻⁶/°C)
  • L₀ = original length (m or ft)
  • ΔT = temperature change (°C or °F)

For concrete, α is typically between 7 and 13 × 10⁻⁶ per °C. The calculator uses the input α directly in the expression, so you can enter any value that matches your specific mix or aggregate type.

Worked Example

Using the default values: L₀ = 10 m, ΔT = 30 °C, α = 10 × 10⁻⁶ /°C.

  1. Convert α to a decimal: 10 × 10⁻⁶ = 0.000010 /°C
  2. Multiply: ΔL = 0.000010 × 10 m × 30 °C = 0.003 m
  3. Convert to millimeters: 0.003 m × 1000 = 3.00 mm

The calculator shows 3.00 mm (0.118 inches). That means a 10-meter-long concrete slab will expand about 3 mm if its temperature rises by 30 °C.

Assumptions

  • The concrete is free to expand or contract (no restraint).
  • The temperature change is uniform throughout the member.
  • The coefficient α is constant over the temperature range (it actually varies slightly, but this is acceptable for most engineering estimates).
  • No moisture effects (drying shrinkage or swelling) are included.

Typical Coefficient Values for Concrete

The coefficient of thermal expansion for concrete is not a single number—it depends on the aggregate type, mix proportions, and moisture content. Typical ranges are:

  • Quartzite aggregate: 11–13 × 10⁻⁶ /°C
  • Sandstone aggregate: 9–12 × 10⁻⁶ /°C
  • Limestone aggregate: 6–9 × 10⁻⁶ /°C
  • Lightweight concrete: 7–11 × 10⁻⁶ /°C

If you don’t know your aggregate, 10 × 10⁻⁶ /°C is a common average for normal-weight concrete. For precise design, use the value from your mix design or local code (e.g., ACI 318 recommends 10 × 10⁻⁶ /°C for temperature effects).

How to Use the Calculator

Follow these steps:

  1. Measure the original length of the concrete member (slab, wall, beam) in meters.
  2. Determine the expected temperature change (difference between maximum and minimum temperature the concrete will experience).
  3. Choose the coefficient α based on your aggregate type or mix design.
  4. Enter the values and read the change in length in millimeters and inches.

The result is the total expansion or contraction. If the temperature drops, ΔT is negative, and the result is negative, meaning the concrete shortens.

Why It Matters: Expansion Joints and Cracking

Concrete moves with temperature. A 30-meter-long pavement exposed to a 40 °C seasonal swing can move about 12 mm. If that movement is restrained—by friction with the ground, adjacent structures, or reinforcement—internal stresses build up. When tensile stress exceeds the concrete’s tensile strength (typically 2–4 MPa), cracking occurs. Expansion joints are placed at regular intervals to allow the concrete to move freely. The joint spacing is often based on the expected movement: for example, a joint every 4.5–9 meters for slabs, depending on thickness and aggregate. This calculator gives you the movement per segment, which you can use to size joint widths.

Common Mistakes and Limitations

  • Unit mix-ups: The calculator expects α in 10⁻⁶/°C. If you enter α as 0.000010, the result will be off by a factor of 10⁶. Always use the same unit for length (meters) and temperature (°C).
  • Ignoring restraint: The formula assumes free movement. In reality, restraint creates stress, not just movement. For restrained members, calculate stress as σ = E × α × ΔT, where E is the modulus of elasticity (about 30 GPa for concrete).
  • Temperature vs. moisture: Concrete also shrinks as it dries (drying shrinkage) and swells with moisture. This calculator only handles thermal movement; for total movement, add shrinkage estimates from your code.
  • Non-uniform temperature: In thick sections, the interior may be cooler than the surface, causing differential expansion and potential thermal cracking. This is a more complex analysis beyond simple linear expansion.

Alternatives and Related Calculations

For a quick estimate, you can use the rule of thumb: a 10 °C change moves a 10 m slab about 1 mm (with α = 10 × 10⁻⁶). For more accurate design, use finite element software or consult structural codes. If you need to find the temperature change for a given allowable movement, rearrange the formula: ΔT = ΔL / (α × L₀). This calculator is for linear expansion; for volume expansion of concrete (rarely needed), multiply the linear coefficient by 3.

Safety and Accuracy Notes

This calculator is for engineering estimation and study purposes only. Always follow your local building codes and consult a structural engineer for actual joint spacing and reinforcement design. The coefficient α varies with mix and moisture, so verify it with your supplier or test data. For critical structures, use measured values rather than averages.

Frequently Asked Questions

What is the coefficient of thermal expansion of concrete?

Typical values range from 7 to 13 × 10⁻⁶ per °C, depending on aggregate. A common default is 10 × 10⁻⁶ /°C for normal-weight concrete.

How much does a 20-foot concrete slab expand with a 50°F temperature change?

First convert to metric: 20 ft = 6.096 m, 50°F change = 27.78°C. Using α = 10 × 10⁻⁶, ΔL = 10e-6 × 6.096 × 27.78 = 0.00169 m = 1.69 mm (0.067 inches).

Does reinforcement stop thermal expansion?

No, reinforcement does not prevent thermal expansion; it distributes cracking and holds cracks closed. The concrete still expands and contracts with temperature.

Why does concrete crack if it expands?

Expansion itself doesn’t crack concrete—restraint does. If the concrete cannot move freely, tensile stresses develop, and when they exceed the concrete’s tensile strength, it cracks.

Can I use this calculator for concrete pavements?

Yes, but for pavements you also need to consider drying shrinkage and traffic loads. Use the movement to size expansion joints, but follow AASHTO or local pavement design guides for joint spacing.

What is the difference between thermal expansion and thermal stress?

Thermal expansion is the change in dimension (ΔL). Thermal stress is the internal force per area when expansion is restrained, calculated as σ = E × α × ΔT. This calculator gives expansion; use the stress formula separately.

Related

Formula used
in m | Original length | m | 10 | 0.001
in dT | Temperature change | °C | 30 | -273.15
in a | Coefficient of thermal expansion (×10⁻⁶/°C) | 10⁻⁶/°C | 10 | 0
out dL | Change in length | mm | a * 1e-6 * m * dT * 1000 | 2
out dL_in | Change in length | inches | dL / 25.4 | 3

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →