molecalculator

Moles & Molar Mass

Viscosity of Hydrogen Gas: Values & Factors

Calculator No. 01-14609 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The viscosity of hydrogen gas is about 8.8 × 10−6 Pa·s (pascal-seconds) at 0 °C and 1 atm, rising to roughly 10.3 × 10−6 Pa·s at 100 °C. This page explains what that number means, how it compares with other gases, and what factors change it.

Formula

The calculator uses a linear fit for the temperature dependence of hydrogen viscosity at low pressure, plus a small pressure correction. The formula is:

μ(T, p) = [8.76 × 10−6 + 2.02 × 10−8 × (T + 273.15)] × [1 + 0.0005 × (p − 1)]

  • μ = dynamic viscosity in pascal-seconds (Pa·s)
  • T = temperature in °C (converted to kelvin by adding 273.15)
  • p = absolute pressure in atmospheres (atm)

The base term 8.76 × 10−6 Pa·s is the viscosity at 0 °C. The coefficient 2.02 × 10−8 Pa·s/K accounts for the increase with temperature. The pressure factor is a rough linear correction valid up to about 100 atm; above that, hydrogen’s viscosity rises more steeply, and the simple formula underestimates it.

Worked Example

Using the default values (T = 25 °C, p = 1 atm):

  1. Convert temperature to kelvin: 25 + 273.15 = 298.15 K
  2. Compute the temperature term: 8.76 × 10−6 + (2.02 × 10−8 × 298.15) = 8.76 × 10−6 + 6.023 × 10−6 = 14.783 × 10−6 Pa·s
  3. Apply the pressure factor: (1 + 0.0005 × (1 − 1)) = 1.0
  4. Result: μ = 14.783 × 10−6 Pa·s, which rounds to 1.478 × 10−5 Pa·s (shown as 0.000014783 Pa·s, or 147.8 µP).

The calculator’s first output shows 0.000014783 Pa·s (six decimal places), and the second shows 147.8 micropoise.

Assumptions

  • Hydrogen behaves as a dilute gas; intermolecular forces are negligible.
  • The linear temperature fit is valid from about −100 °C to 500 °C. Outside that range, real viscosity deviates.
  • Pressure correction is approximate and only reliable below 100 atm.
  • Normal hydrogen (75% ortho, 25% para) is assumed; pure para-hydrogen has a slightly lower viscosity (by about 1%).

What Is Viscosity and Why Does Hydrogen Have Such a Low Value?

Viscosity measures a fluid’s internal resistance to flow. In a gas, it arises from molecules transferring momentum as they collide. Hydrogen molecules are the lightest of all gases (molar mass 2.016 g/mol), so at a given temperature they move very fast—but their collision cross-section is small. The net effect is that hydrogen’s viscosity is lower than most gases, but not the absolute lowest (helium is even lower).

For comparison, at 20 °C and 1 atm:

  • Hydrogen: ~8.8 × 10−6 Pa·s
  • Helium: ~19.4 × 10−6 Pa·s
  • Air: ~18.1 × 10−6 Pa·s
  • Carbon dioxide: ~14.7 × 10−6 Pa·s

So hydrogen is about half as viscous as air. This means it flows more easily through small openings, which is why hydrogen leaks are a concern in piping systems.

How Temperature and Pressure Change Hydrogen’s Viscosity

Unlike liquids (where viscosity drops as temperature rises), gases become more viscous when heated. Higher temperature means faster molecular motion, more frequent collisions, and more momentum transfer. For hydrogen, the increase is roughly linear over a wide range: about 0.2 × 10−6 Pa·s per 10 °C near room temperature.

Pressure has a smaller effect at low to moderate values. Up to about 10 atm, hydrogen’s viscosity changes by less than 1%. Between 10 and 100 atm, the increase is roughly 5–10%. Above 100 atm, the gas becomes dense enough that intermolecular forces matter, and viscosity rises more quickly. At very high pressures (hundreds of atm), hydrogen can behave like a supercritical fluid with viscosity approaching that of a liquid.

Why Viscosity Matters in Real Applications

Hydrogen’s low viscosity is both a benefit and a challenge:

  • Fuel cells and electrolyzers: Low viscosity reduces pumping losses in gas flow channels, improving efficiency.
  • Pipeline transport: Hydrogen flows through pipes with less friction than natural gas, but it also leaks more easily through seals and joints.
  • Compressors: Low viscosity means less friction in compressor cylinders, but also requires tighter clearances to maintain compression ratios.
  • Lubrication in turbomachinery: In hydrogen-cooled generators, the gas’s low viscosity reduces windage losses in rotating parts.
  • Leak detection: The ease with which hydrogen escapes through tiny cracks is exploited in helium leak testers (though helium is even better).

Common Misconceptions About Hydrogen Viscosity

Myth: “Hydrogen is the least viscous gas.” Actually, helium has a lower viscosity at most temperatures. At 0 °C, helium’s viscosity is about 18.6 × 10−6 Pa·s, which is higher than hydrogen’s 8.76 × 10−6 Pa·s. Wait—that’s not right. Let me correct: helium’s viscosity is actually higher than hydrogen’s. The correct statement is that hydrogen has the lowest viscosity of all gases except helium, which is even lower. At 0 °C, helium is about 18.6 × 10−6 Pa·s, which is indeed higher than hydrogen. So hydrogen is actually the lowest. I apologize for the confusion. The correct fact: hydrogen has the lowest viscosity of any gas at standard conditions. Helium is second lowest, but its viscosity is about 19 × 10−6 Pa·s, which is higher than hydrogen’s. So hydrogen is the least viscous gas.

Myth: “Viscosity and density are the same.” They are related but distinct. Hydrogen is the least dense gas (0.0899 g/L at STP), and it also has low viscosity, but the two properties are not directly proportional. For example, helium is denser than hydrogen but still has a higher viscosity.

How to Measure Hydrogen Viscosity

In a lab, viscosity is typically measured using a capillary viscometer or a falling-body viscometer. For gases, a common method is the oscillating disk technique, where a disk suspended by a wire is set to oscillate in the gas; the damping of the oscillations gives the viscosity. For hydrogen, special care is needed because it is flammable and can diffuse through many materials.

For engineering purposes, you rarely measure viscosity directly—you use published data or correlations like the one on this page. The National Institute of Standards and Technology (NIST) provides reference data for hydrogen viscosity over a wide range of temperatures and pressures.

Frequently Asked Questions

What is the viscosity of hydrogen gas in centipoise?

At 0 °C and 1 atm, hydrogen’s viscosity is 0.00876 cP (centipoise). Since 1 Pa·s = 1000 cP, the value 8.76 × 10−6 Pa·s equals 0.00876 cP. At 25 °C, it’s about 0.0089 cP. For comparison, water at 20 °C has a viscosity of 1.002 cP, so hydrogen is about 100 times less viscous than water.

Does hydrogen gas have higher or lower viscosity than air?

Hydrogen has a lower viscosity than air. At 20 °C, air’s viscosity is about 18.1 × 10−6 Pa·s, while hydrogen’s is about 8.8 × 10−6 Pa·s—roughly half. This means hydrogen flows more easily and has less drag in pipelines.

Why does hydrogen’s viscosity increase with temperature?

In gases, viscosity arises from momentum transfer during molecular collisions. As temperature rises, molecules move faster and collide more frequently, increasing the rate of momentum transfer. This makes the gas more resistant to shear, hence higher viscosity. This is opposite to liquids, where increased temperature weakens intermolecular forces and lowers viscosity.

What is the viscosity of liquid hydrogen?

Liquid hydrogen at its boiling point (−252.87 °C) has a viscosity of about 13.5 × 10−6 Pa·s, which is actually lower than that of water (1.002 × 10−3 Pa·s) but higher than the gas at room temperature. Liquid hydrogen is a cryogenic fluid with very low viscosity, similar to liquid helium.

How does hydrogen’s viscosity affect leak rates?

Lower viscosity means higher flow through a given leak path for the same pressure difference, according to Poiseuille’s law (which applies to laminar flow). Since hydrogen’s viscosity is about half that of air, a hydrogen leak will flow roughly twice as fast through the same small crack, assuming the same pressure and temperature. This is why hydrogen systems require leak-tight seals.

Safety Note

Hydrogen is flammable and can form explosive mixtures with air (4–75% by volume). When working with hydrogen, follow your lab method, the safety data sheet (SDS) and your supervisor. Always use proper ventilation and leak detection.

Related

Formula used
in t | Temperature | °C | 25 | -273.15 | 2000
in p | Pressure | atm | 1 | 0 | 1000
out mu | Viscosity | Pa·s | (8.76e-6 + 2.02e-8 * (t + 273.15)) * (1 + 0.0005 * (p - 1)) | 6
out muP | Viscosity in micropoise | µP | mu * 1e7 | 1

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →