molecalculator

Moles & Molar Mass

Enthalpy of Vaporization: Definition & Formula

Calculator No. 01-14629 · Updated · Formula and assumptions shown below

Enthalpy of vaporization 43.58 kJ/mol
Normal boiling point
98.19 °C
Result, rounded to 2 decimal places
Temperature 1
25 °C
Set in the form below
Vapor pressure 1
3.17 kPa
Set in the form below
You enter
Temperature 1 (°C), Vapor pressure 1 (kPa), Temperature 2 (°C), Vapor pressure 2 (kPa)
You get
Enthalpy of vaporization (kJ/mol), Normal boiling point (°C)
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

This calculator works out the enthalpy of vaporization (ΔHvap) of a liquid from its vapor pressure at two temperatures, using the Clausius–Clapeyron equation. You enter the two temperatures and the corresponding vapor pressures, and the calculator returns the molar enthalpy of vaporization in kJ/mol, along with the normal boiling point if one of the pressures is 1 atm. The result tells you how much heat is needed to turn one mole of the liquid into vapor at constant pressure.

Formula

The Clausius–Clapeyron equation relates vapor pressure to temperature:

ln(P2/P1) = −(ΔHvap/R) × (1/T2 − 1/T1)

Solving for ΔHvap:

ΔHvap = −R × ln(P2/P1) / (1/T2 − 1/T1)

  • ΔHvap – molar enthalpy of vaporization (J/mol, converted to kJ/mol in the calculator)
  • R – gas constant, 8.31446261815324 J/(mol·K)
  • P1, P2 – vapor pressures at temperatures T1 and T2 (same units, here kPa)
  • T1, T2 – absolute temperatures (K = °C + 273.15)

The normal boiling point is found by setting P2 = 101.325 kPa and solving for T2.

Worked Example

Using the defaults for water: T1 = 25 °C, P1 = 3.17 kPa; T2 = 50 °C, P2 = 12.35 kPa.

Step 1: Convert temperatures to kelvin.

T1 = 25 + 273.15 = 298.15 K
T2 = 50 + 273.15 = 323.15 K

Step 2: Compute the ratio and natural log.

P2/P1 = 12.35 / 3.17 = 3.8959
ln(3.8959) = 1.3598

Step 3: Apply the Clausius–Clapeyron equation.

ΔHvap = −8.31446261815324 × 1.3598 / (1/323.15 − 1/298.15)

1/323.15 = 0.0030945, 1/298.15 = 0.0033540, difference = −0.0002595

ΔHvap = −8.31446261815324 × 1.3598 / (−0.0002595) = 43,560 J/mol = 43.56 kJ/mol

The calculator rounds to 43.56 kJ/mol, close to the accepted value for water (40.7 kJ/mol at 100 °C; the value varies with temperature).

Assumptions

  • The vapor behaves as an ideal gas.
  • The molar volume of the liquid is negligible compared to that of the vapor.
  • ΔHvap is constant over the temperature range (a reasonable approximation for small ranges).
  • Vapor pressures are measured at equilibrium.

What Is Enthalpy of Vaporization?

Enthalpy of vaporization (ΔHvap) is the heat absorbed when one mole of a pure liquid changes to vapor at constant pressure. It is a molar quantity, usually reported in kJ/mol or J/mol. The process is endothermic because energy is needed to overcome intermolecular forces (hydrogen bonds, dipole–dipole, London dispersion) that hold molecules together in the liquid.

For example, water has a high ΔHvap (~40.7 kJ/mol at its normal boiling point) because of strong hydrogen bonding. Nonpolar liquids like hexane have lower values (~28.9 kJ/mol). The stronger the intermolecular forces, the higher the enthalpy of vaporization.

It is important to distinguish ΔHvap from specific heat capacity. Specific heat is the energy to raise the temperature of a substance; ΔHvap is the energy to change phase at constant temperature. During vaporization, the temperature stays constant while heat is added.

How to Measure or Estimate It

The most direct experimental method is calorimetry: measure the heat input and the mass of liquid vaporized at constant pressure. In practice, the Clausius–Clapeyron equation is widely used because vapor pressure data are easier to obtain.

For quick estimates, Trouton’s rule states that for many nonpolar liquids, ΔHvap ≈ 85 J/(mol·K) × Tb (where Tb is the normal boiling point in kelvin). This gives a rough value, accurate to about ±30% for polar liquids.

Another method uses the Watson relation to adjust ΔHvap from one temperature to another, but that requires a known reference value.

Common Mistakes and Misconceptions

  • Using Celsius instead of Kelvin: The equation requires absolute temperature. Always add 273.15.
  • Mixing pressure units: The ratio P2/P1 is unitless, but both pressures must be in the same unit. The calculator uses kPa; if you have mmHg, convert (1 atm = 760 mmHg = 101.325 kPa).
  • Assuming ΔHvap is constant over wide temperature ranges: It decreases with increasing temperature and becomes zero at the critical point. The Clausius–Clapeyron equation is most accurate for small temperature intervals.
  • Confusing enthalpy of vaporization with enthalpy of fusion: Fusion (melting) is much smaller; for water, ΔHfus ≈ 6.0 kJ/mol vs. 40.7 kJ/mol for vaporization.
  • Thinking that boiling point is the only temperature where vaporization occurs: Evaporation happens at all temperatures, but boiling occurs when vapor pressure equals ambient pressure.

Applications and Why It Matters

Enthalpy of vaporization appears in many real-world contexts:

  • Distillation: Designing separation columns requires knowing how much heat is needed to vaporize components.
  • Cooling systems: Sweating and evaporative coolers work because vaporization absorbs heat from the surroundings.
  • Chemical engineering: Sizing reboilers, condensers, and heat exchangers.
  • Climate science: The energy absorbed when water evaporates drives weather patterns and the water cycle.
  • Safety: The heat required to vaporize a spilled liquid affects how quickly it cools surfaces and how dangerous a fire might be.

In the lab, knowing ΔHvap helps predict how a solvent behaves under reduced pressure (rotary evaporation) or how much heat a reaction will absorb if a solvent evaporates.

Frequently Asked Questions

What is the difference between enthalpy of vaporization and heat of vaporization?

They are the same thing. “Heat of vaporization” is an older, informal term; enthalpy is the precise thermodynamic quantity. At constant pressure, the heat absorbed equals the enthalpy change.

Why does water have such a high enthalpy of vaporization?

Water molecules form strong hydrogen bonds. Breaking these bonds requires a lot of energy—about 40.7 kJ/mol at 100 °C. That is why water is effective at cooling (sweat) and why steam burns are so severe: steam releases this large amount of heat when it condenses on skin.

Can I use the Clausius–Clapeyron equation for any liquid?

It works best for pure liquids over small temperature ranges where the vapor behaves ideally. For mixtures or near the critical point, it becomes inaccurate. For polar liquids that associate in the vapor phase (like acetic acid), corrections are needed.

How do I find vapor pressure data?

Common sources include the NIST Chemistry WebBook, the CRC Handbook of Chemistry and Physics, and the Dortmund Data Bank. Many textbooks include vapor pressure tables for common solvents. Alternatively, you can measure vapor pressure in the lab using a simple manometer.

What is the normal boiling point and how is it related to ΔHvap?

The normal boiling point is the temperature at which the vapor pressure equals 1 atm (101.325 kPa). The Clausius–Clapeyron equation can be used to find it if you know ΔHvap and one vapor pressure–temperature point. Conversely, if you have two vapor pressure points, you can compute ΔHvap and then the boiling point, as this calculator does.

Does ΔHvap change with temperature?

Yes. It decreases as temperature increases and becomes zero at the critical point. The Clausius–Clapeyron equation assumes it is constant, which is a good approximation for small temperature ranges. For precise work, use the more complex Antoine equation or look up tabulated values at the specific temperature.

Limitations of the Calculator

This calculator assumes ideal gas behavior and constant ΔHvap over the temperature interval. For large temperature differences (more than ~50 °C), the result may deviate from experimental values. Also, the input pressures must be equilibrium vapor pressures; using partial pressures from a mixture will give incorrect results. For safety and accuracy in the lab, always follow your lab method, the safety data sheet (SDS), and your supervisor.

Related

Formula used
in t1 | Temperature 1 | °C | 25 | -273.15
in p1 | Vapor pressure 1 | kPa | 3.17 | 0
in t2 | Temperature 2 | °C | 50 | -273.15
in p2 | Vapor pressure 2 | kPa | 12.35 | 0
out hvap | Enthalpy of vaporization | kJ/mol | (8.31446261815324 * (t1 + 273.15) * (t2 + 273.15) * ln(p2 / p1) / (t2 - t1)) / 1000 | 2
out bp | Normal boiling point | °C | (1 / (1 / (t1 + 273.15) - (8.31446261815324 / (hvap * 1000)) * ln(101.325 / p1))) - 273.15 | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →