molecalculator

Moles & Molar Mass

A260/A280 Ratio for DNA Purity: What It Means

Calculator No. 01-9809 · Updated · Formula and assumptions shown below

A260/A280 ratio 1.80
Absorbance at 260 nm (A260)
0.5
Set in the form below
Absorbance at 280 nm (A280)
0.278
Set in the form below
You enter
Absorbance at 260 nm (A260), Absorbance at 280 nm (A280)
You get
A260/A280 ratio
Rounding
2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The A260/A280 ratio is a spectrophotometric measure used to assess the purity of a DNA sample, with a value of ~1.8 generally accepted as pure for double-stranded DNA. You measure the absorbance of your sample at 260 nm and 280 nm, divide the first by the second, and compare the result to the reference value. This article explains how the ratio works, what affects it, and how to interpret your readings accurately.

Formula

The A260/A280 ratio is simply the absorbance of the sample at 260 nm divided by the absorbance at 280 nm:

Ratio = A260 / A280

  • A260 – absorbance at 260 nm (no unit; it is a logarithmic measure of light transmission)
  • A280 – absorbance at 280 nm (no unit)

Both values come from a spectrophotometer or microvolume reader. The ratio itself has no unit; it is a dimensionless number used as a quality indicator.

Worked Example

Using the default values from the calculator above (A260 = 0.500, A280 = 0.278):

  1. Measure the absorbance of your DNA sample at 260 nm: A260 = 0.500.
  2. Measure the absorbance at 280 nm: A280 = 0.278.
  3. Divide: 0.500 ÷ 0.278 = 1.799.

The result is 1.80, which is the expected ratio for pure double-stranded DNA.

Assumptions

  • The sample is measured in a cuvette or microvolume pedestal with a defined path length (typically 1 cm or adjusted by the instrument).
  • The buffer or water used as blank has negligible absorbance at 260 nm and 280 nm.
  • The DNA is in solution and not bound to proteins or other contaminants that absorb at 280 nm.
  • The instrument is properly calibrated and the sample is within the linear absorbance range (usually 0.1–1.0 for accurate readings).

Why the Ratio Matters

Nucleic acids absorb strongly at 260 nm due to the aromatic rings in their bases. Proteins, on the other hand, have a peak absorbance around 280 nm because of the aromatic amino acids tryptophan and tyrosine. By comparing the two absorbances, you get a quick, label-free estimate of whether your DNA preparation is contaminated with protein or other organic compounds.

A pure double-stranded DNA sample typically gives a ratio of 1.8. If the ratio is significantly lower (e.g., 1.5), it suggests protein contamination. If it is higher (e.g., 2.0 or above), it may indicate RNA contamination, residual phenol, or other issues. However, the ratio alone is not a definitive purity test – it is a screening tool.

What Affects the Ratio

Several factors can shift your A260/A280 reading even when the DNA is pure:

  • pH of the buffer: The absorbance of nucleic acids and proteins changes with pH. Measurements in water (pH ~5–6) often give lower ratios (around 1.7–1.8) than measurements in alkaline buffers (pH 8–9), which can give ratios near 2.0 for the same sample. Always report the buffer used.
  • Presence of RNA: RNA absorbs at 260 nm and has a ratio of ~2.0. A DNA sample contaminated with RNA will show an elevated ratio.
  • Residual reagents: Phenol, guanidine, and other chaotropic salts used in DNA extraction absorb near 260–280 nm and can skew the ratio. Phenol contamination often raises the ratio above 2.0.
  • Carbohydrates and other organics: Some polysaccharides and organic solvents can absorb at 260 nm, leading to falsely high ratios.
  • Sample concentration: If the absorbance values are too low (<0.1) or too high (>1.5), the measurement becomes less reliable due to noise or detector saturation.

How to Use the Ratio in Practice

When you prepare DNA for downstream applications like PCR, restriction digestion, or sequencing, you want to know whether your sample is clean enough. The A260/A280 ratio gives you a quick check, but it should not be your only criterion.

  1. Measure the absorbance of your blank (buffer or water) and zero the instrument.
  2. Measure your DNA sample at 260 nm and 280 nm.
  3. Calculate the ratio using the calculator above.
  4. Compare to the expected value for your nucleic acid type: ~1.8 for dsDNA, ~2.0 for RNA.
  5. If the ratio is off, consider additional purification (e.g., phenol-chloroform extraction, ethanol precipitation, or column cleanup) before proceeding.

Remember that the ratio is a relative measure – it tells you about contaminants relative to nucleic acid concentration, but it does not tell you the absolute purity or the integrity of the DNA (e.g., fragmentation).

Common Problems and Misconceptions

One common misconception is that a ratio of exactly 1.8 guarantees pure DNA. In reality, a sample with a ratio of 1.8 could still contain significant amounts of protein if the DNA concentration is very high, or it could be slightly contaminated with RNA that compensates for protein contamination. Conversely, a ratio of 1.7 might be perfectly fine for many applications if the DNA is intact and the buffer pH is low.

Another issue is measuring in water versus buffer. Many researchers measure DNA in water for convenience, but water’s low pH can suppress the 280 nm absorbance, giving a falsely low ratio. For more accurate results, measure in a slightly alkaline buffer like 10 mM Tris-Cl (pH 8.0).

Also, be aware that the ratio is not linear with contaminant concentration. A small amount of protein can cause a noticeable drop in the ratio, but beyond a certain point, the ratio plateaus. So a ratio of 1.5 does not mean twice the protein as a ratio of 1.65 – it just indicates significant contamination.

Alternatives and Complementary Methods

The A260/A280 ratio is not the only way to assess DNA purity. Consider these complementary approaches:

  • A260/A230 ratio: Absorbance at 260 nm divided by absorbance at 230 nm. This ratio is more sensitive to contamination by chaotropic salts, phenol, and carbohydrates. A pure DNA sample typically has an A260/A230 ratio of 2.0–2.2. A lower value (e.g., <1.5) indicates organic contamination.
  • Fluorometric quantification: Dyes like PicoGreen or Qubit assays bind specifically to double-stranded DNA and are not affected by RNA, proteins, or free nucleotides. This gives a more accurate concentration measurement, which indirectly reflects purity if you compare it to the absorbance-based concentration.
  • Agarose gel electrophoresis: Running a small aliquot on a gel lets you visualize DNA integrity and detect high-molecular-weight RNA or genomic DNA contamination. It does not give a numeric purity value, but it is a direct check for degradation.
  • Mass spectrometry or HPLC: These are high-end methods used when absolute purity is critical, such as in pharmaceutical-grade DNA, but they are not routine for most labs.

For most molecular biology work, a combination of A260/A280 and A260/A230 ratios, along with a gel check, is sufficient to ensure your DNA is usable.

Frequently Asked Questions

What is a good A260/A280 ratio for DNA?
For pure double-stranded DNA, a ratio of about 1.8 is considered good. Values between 1.7 and 1.9 are generally acceptable for most downstream applications. If your ratio is below 1.7, it suggests protein contamination; if above 1.9, it may indicate RNA or phenol contamination.

Why is my A260/A280 ratio low?
A low ratio (e.g., 1.5–1.7) usually indicates protein contamination in your DNA sample. This can happen if the proteinase K digestion was incomplete, if the organic extraction was not thorough, or if the DNA was not washed properly during purification. Re-purify the sample using phenol-chloroform extraction or a column-based cleanup kit.

Can the A260/A280 ratio be too high?
Yes. A ratio above 2.0 for DNA often indicates RNA contamination, because RNA has a ratio of ~2.0. It can also be caused by residual phenol (which absorbs at 260 nm) or by measuring in a high-pH buffer. Check your sample on a gel to see if RNA is present.

Does the buffer affect the A260/A280 ratio?
Yes, significantly. The pH of the solution changes the absorbance of both nucleic acids and proteins. For example, DNA in water (pH ~5) typically gives a ratio of 1.7–1.8, while the same DNA in Tris buffer (pH 8) may give 1.9–2.0. Always measure in a consistent buffer and report it.

How do I get a more accurate purity assessment?
Use the A260/A230 ratio as a second measure, and consider fluorometric quantification with a DNA-binding dye. If you suspect contamination, run an agarose gel to check for RNA or protein smears. For critical applications, use a kit that removes all contaminants and verify with a sensitive assay.

Related

Formula used
in a | Absorbance at 260 nm (A260) | - | 0.5 | 0 | 5
in b | Absorbance at 280 nm (A280) | - | 0.278 | 0 | 5
out r | A260/A280 ratio | - | a / b | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →