The acid-base buffer equation is the Henderson–Hasselbalch equation: pH = pKa + log([A⁻]/[HA]), where [A⁻] is the concentration of the conjugate base and [HA] is the concentration of the weak acid. This equation lets you calculate the pH of a buffer solution or determine the ratio of base to acid needed to achieve a target pH.
Formula
The Henderson–Hasselbalch equation is written as:
pH = pKa + log10([A⁻] / [HA])
where:
- pH = the negative logarithm of the hydrogen ion concentration (unitless)
- pKa = the negative logarithm of the acid dissociation constant (Ka) of the weak acid (unitless)
- [A⁻] = molar concentration of the conjugate base (mol/L, often mmol/L in lab work)
- [HA] = molar concentration of the weak acid (mol/L)
The equation is derived from the equilibrium expression for a weak acid: Ka = [H⁺][A⁻]/[HA]. Taking the negative logarithm of both sides and rearranging gives the form above. It is valid when the acid is weak (Ka small) and the concentrations are high enough that the dissociation of the acid itself is negligible compared to the added amounts.
Worked Example
Using the calculator defaults: acetic acid (pKa = 4.75) at 0.100 mmol/L and sodium acetate (conjugate base) at 0.100 mmol/L.
Step 1: Write the equation: pH = 4.75 + log10(0.100 / 0.100)
Step 2: Compute the ratio: 0.100 / 0.100 = 1.000
Step 3: Take the logarithm: log10(1.000) = 0
Step 4: Add the pKa: pH = 4.75 + 0 = 4.75
The calculator returns pH = 4.75, matching the expected result. When acid and base concentrations are equal, the buffer pH equals the pKa.
Assumptions
- Ideal dilute solution – activity coefficients are ignored.
- The weak acid is only partially dissociated; the added conjugate base suppresses further dissociation.
- Temperature is 25 °C unless stated otherwise – pKa values are temperature-dependent.
- The concentrations are the total analytical concentrations of the acid and base forms, not equilibrium concentrations.
- For polyprotic acids, the equation applies to one ionization step at a time.
How to Use the Equation to Prepare a Buffer
To make a buffer at a specific pH, you need to choose a weak acid whose pKa is close to the target pH (within about 1 unit). Then use the equation to find the required ratio of conjugate base to acid:
- Decide the target pH and the buffer capacity (total concentration of acid plus base, typically 0.01–0.1 mol/L).
- Calculate the ratio [A⁻]/[HA] = 10(pH − pKa).
- From the ratio and the total concentration, compute the individual concentrations. For example, if total C = [HA] + [A⁻] and r = [A⁻]/[HA], then [HA] = C/(1+r) and [A⁻] = r·C/(1+r).
- Weigh out the appropriate amounts of the acid and its salt (or use a strong base to partially neutralize the acid).
- Dissolve in about 80% of the final volume, adjust pH with a pH meter, then bring to final volume.
Always verify the final pH with a calibrated pH meter, because temperature and ionic strength shift the actual pH.
Common Mistakes and Misconceptions
- Using the wrong pKa: For polyprotic acids (like phosphoric acid), use the pKa closest to the target pH (pKa1, pKa2, or pKa3).
- Forgetting the logarithm: The ratio is not linear; a 10:1 base-to-acid ratio changes pH by only 1 unit.
- Ignoring temperature: pKa changes with temperature; a buffer made at 25 °C will have a different pH at 37 °C.
- Using concentrations instead of activities: In very concentrated buffers or high ionic strength, the equation becomes approximate.
- Assuming complete dissociation of the weak acid: The equation accounts for partial dissociation, but only if the acid is truly weak.
Limits of the Henderson–Hasselbalch Equation
The equation is most accurate when the pH is within about 1 unit of the pKa. Outside that range, the buffer capacity is low, and the approximations break down. Also, when the acid concentration is very low (below about 10−4 mol/L), the self-ionization of water becomes significant, and the equation underestimates the hydrogen ion contribution. For precise work, use a full equilibrium calculation or a pH meter.
Comparison with Alternative Approaches
For simple buffers, the Henderson–Hasselbalch equation is the standard. However, for strong acid/strong base systems or very dilute solutions, you may need to use the charge balance and mass balance equations directly. For example, the pH of a strong acid solution is simply the negative log of the acid concentration, with no buffer equation needed. For mixtures of multiple weak acids, iterative numerical methods are required.
Safety and Practical Tips
When preparing buffers in the lab, always follow your lab method, the safety data sheet (SDS) and your supervisor. Wear appropriate personal protective equipment, especially when handling concentrated acids or bases. The pH meter reading is the real check – temperature and ionic strength shift pH, so calibrate the meter at the same temperature as your buffer. Store buffers in tightly sealed containers to prevent evaporation and CO₂ absorption, which can change pH over time.
Frequently Asked Questions
What is the difference between pKa and pH? pKa is a property of a specific acid, indicating the pH at which half of the acid is dissociated. pH is the actual acidity of a solution. A buffer works best when pH is close to pKa.
Why is the buffer capacity maximum at pH = pKa? At pH = pKa, the concentrations of acid and conjugate base are equal, so the buffer can neutralize added H⁺ or OH⁻ with the least change in pH. The capacity decreases as you move away from that point.
Can I use the Henderson–Hasselbalch equation for strong acids? No, it applies only to weak acids and their conjugate bases. Strong acids dissociate completely, so the equation’s assumptions fail.
How do I choose a buffer for a biological experiment? Select a weak acid with a pKa within 0.5–1 unit of your target pH. Also consider the buffer’s ionic strength, temperature sensitivity, and whether it interferes with your assay (e.g., phosphate inhibits some enzymes).
What is the difference between a buffer and a solution of a weak acid alone? A buffer contains both the weak acid and its conjugate base, so it resists pH changes. A weak acid alone has some buffering action, but only when partially neutralized.
Does the equation work for bases? Yes, you can use the same form with the pKa of the conjugate acid. For a weak base (B), you would use pKa of BH⁺ and the ratio [B]/[BH⁺].
Related
Formula used
in mm | Acid concentration (HA) | mmol/L | 0.100 | 0.000001 | 10 in mm2 | Base concentration (A-) | mmol/L | 0.100 | 0.000001 | 10 in pka | pKa of weak acid | - | 4.75 | -20 | 20 out ph | Buffer pH | - | pka + log10(mm2 / mm) | 2 out ratio | [A-]/[HA] ratio | - | mm2 / mm | 3
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Degree of Reaction Formula & How to Use It
- Equivalence Point pH Curve Explained
- Enzyme Reaction Rate Equation Explained
- Delta G Reaction Formula & How to Use It
- D&D Hit Point Calculator: How HP Works
- Calculating pH at Equivalence Point