molecalculator

Moles & Molar Mass

Thermal Conductivity: How to Calculate It

Calculator No. 01-10351 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

To calculate thermal conductivity, you use the steady-state heat conduction equation: k = (Q × L) / (A × ΔT × t), where k is thermal conductivity in W/(m·K), Q is heat transferred in joules, L is thickness in meters, A is cross-sectional area in m², ΔT is temperature difference in kelvin, and t is time in seconds. In practice, you either measure these quantities directly or use a known heat flux and geometry to solve for k.

Formula

The defining equation for thermal conductivity comes from Fourier’s law of heat conduction. In its one-dimensional steady-state form, the heat flow rate (power) P through a slab is:

P = k × A × (ΔT / L)

Rearranged for conductivity:

k = P × L / (A × ΔT)

Where:

  • P = heat flow rate (W, watts) – this is the same as the heat Q divided by time t.
  • L = thickness of the material along the heat flow direction (m).
  • A = cross‑sectional area perpendicular to heat flow (m²).
  • ΔT = temperature difference between the hot and cold faces (K or °C, since only the difference matters).
  • k = thermal conductivity in W/(m·K).

The calculator above uses power directly (J/s) instead of separate Q and t, which is the most common practical form. If you know total heat Q in joules and time t in seconds, divide Q by t to get P first.

Worked Example

Using the default values from the calculator:

  • Heat flow P = 50 W
  • Thickness L = 0.01 m (1 cm)
  • Area A = 0.01 m² (100 cm²)
  • Temperature difference ΔT = 20 K

Step 1: Write the formula.

k = P × L / (A × ΔT)

Step 2: Insert the numbers.

k = 50 × 0.01 / (0.01 × 20)

Step 3: Calculate the numerator and denominator.

Numerator = 0.5 W·m

Denominator = 0.2 m²·K

Step 4: Divide.

k = 0.5 / 0.2 = 2.5 W/(m·K)

The calculator gives 2.5 W/(m·K) with three decimal places. This value is in the range of many building materials (e.g., concrete is roughly 1–2 W/(m·K)).

Assumptions

  • Steady‑state conditions – temperatures do not change with time.
  • One‑dimensional heat flow – heat moves only through the thickness, with no edge losses.
  • Uniform material – the sample is homogeneous and isotropic (same k in all directions).
  • Constant thermal conductivity – k does not vary with temperature over the measured range.
  • Perfect thermal contact – the hot and cold surfaces are at uniform temperatures.

These assumptions are rarely perfectly true, but they are the standard basis for the guarded hot‑plate and heat‑flow‑meter methods used in laboratories.

How Thermal Conductivity Is Measured

In the lab, you don’t usually measure k directly. Instead, you set up a known geometry, apply a known heat input, measure the temperature drop, and then solve for k using the same equation.

  • Guarded hot plate: A flat sample is placed between a heated plate and a cold plate. Guard heaters around the edges prevent lateral heat loss. The power input and the temperature difference give k directly. This is the reference method for insulation materials (ASTM C177).
  • Heat flow meter: Similar to the guarded hot plate, but the heat flux is measured with a calibrated sensor rather than from electrical power. Faster and used for routine testing.
  • Laser flash analysis: A short laser pulse heats one face of a thin disc; an infrared detector measures the temperature rise on the opposite face. From the time lag, thermal diffusivity is found, and k = α × ρ × cp (where α is diffusivity, ρ density, cp specific heat). Used for metals, ceramics, and advanced materials.
  • Transient line source: A probe with a heating wire is inserted into a material (soil, food, powder). The temperature response over time yields k. Useful for materials that are hard to shape into flat slabs.

For a quick estimate at home or in a classroom, you can clamp a sample between a heat source of known power and a cold sink, insulate the edges, and measure the temperature difference with two thermocouples. Accuracy is limited by edge losses and contact resistance.

Typical Values and What They Mean

Thermal conductivity spans many orders of magnitude. Knowing where a material falls helps you judge whether a calculated number is plausible.

  • Metals: 15–400 W/(m·K). Copper ≈ 385, aluminum ≈ 205, steel ≈ 50. These conduct heat rapidly.
  • Ceramics and glass: 1–30 W/(m·K). Glass ≈ 1.0, alumina ≈ 30. They are moderate conductors.
  • Polymers and plastics: 0.1–0.5 W/(m·K). Polyethylene ≈ 0.35, polystyrene foam ≈ 0.03. They are good insulators.
  • Wood and building materials: 0.04–0.2 W/(m·K). Softwood ≈ 0.12, brick ≈ 0.7, concrete ≈ 1.5.
  • Gases: 0.01–0.1 W/(m·K). Air ≈ 0.026 at room temperature. That’s why foams trap air to insulate.
  • Liquids: 0.1–0.6 W/(m·K). Water ≈ 0.6, oils ≈ 0.15.

If your calculated k is far outside the expected range for the material, check your units – the most common mistake is using centimeters instead of meters, or mixing °C and K (they are fine to mix in a difference, but not in absolute values).

Common Mistakes and Pitfalls

  • Unit mix‑ups: Always convert thickness to meters and area to square meters. A 1 cm slab is 0.01 m, not 1 m. Forgetting this changes k by a factor of 100.
  • Using diameter instead of radius: If the area is circular, A = πr², not πd². A common error that gives a 4× error.
  • Ignoring contact resistance: The temperature difference you measure might include a drop at the interface between the sample and the plates, making k appear lower than it truly is.
  • Non‑steady state: If you measure before thermal equilibrium is reached, the apparent k will be wrong. Wait until temperatures are stable.
  • Assuming k is constant: For most materials, k changes with temperature. For metals, it generally decreases with rising temperature; for insulators, it increases. The calculated value is only valid for the average temperature of your measurement.
  • Edge heat loss: Without guards or insulation, heat escapes sideways, reducing the heat that flows through the sample and lowering the apparent k.

Choosing a Method for Your Material

Not every method works for every material. The right choice depends on the sample form, the expected k range, and the accuracy you need.

  • Flat solid slabs (insulation, plastics, glass): Use guarded hot plate or heat flow meter. These give the most accurate results for low‑to‑moderate k.
  • Thin films or coatings: The 3‑omega method or laser flash with a thin substrate is needed because the temperature drop across a micrometer‑thick film is tiny.
  • Liquids and powders: Transient line source or transient plane source (hot disc) methods work well because they avoid the need to contain the sample in a solid shape.
  • High‑temperature materials (refractories, ceramics): Laser flash is preferred because it can be adapted to high temperatures (up to 2000 °C) and does not require large samples.
  • Metals: The steady‑state method works, but because k is high, you need a large temperature difference or a very precise heat flux measurement. Laser flash is often easier.

For a quick engineering estimate, you can sometimes look up k in a handbook rather than measure it. But if the material is new or anisotropic (like wood grain or composites), measurement is necessary.

Frequently Asked Questions

What is the difference between thermal conductivity and thermal diffusivity?
Thermal conductivity (k) measures how well a material conducts heat per unit temperature gradient. Thermal diffusivity (α) measures how quickly heat spreads through a material relative to its heat storage capacity: α = k / (ρ × cp). Two materials can have the same k, but the one with lower density or specific heat will reach steady state faster (higher α).

Can I calculate thermal conductivity from electrical conductivity?
For pure metals, there is an empirical relationship called the Wiedemann–Franz law: k / σ = L × T, where σ is electrical conductivity, T is absolute temperature, and L is the Lorenz number (≈2.44×10⁻⁸ W·Ω/K²). This works well for metals at moderate temperatures, but it fails for alloys, semiconductors, and insulators where phonons (lattice vibrations) carry a significant part of the heat.

Why does thermal conductivity matter for insulation?
The lower the k, the better the insulation. The R‑value (thermal resistance) of a slab is R = L / k. Doubling the thickness doubles the R‑value, but using a material with half the k also doubles the R‑value for the same thickness. That’s why foam (k≈0.03) is a far better insulator than brick (k≈0.7).

How does temperature affect thermal conductivity?
For most pure metals, k decreases as temperature rises because electron scattering increases. For non‑metallic solids (ceramics, polymers), k often increases with temperature because more phonons are excited. Gases show a slight increase with temperature. Always note the temperature at which k is measured.

What is the thermal conductivity of air?
At 25 °C and 1 atm, dry air has a thermal conductivity of about 0.026 W/(m·K). This is very low, which is why trapped air in foams, double‑glazed windows, and clothing provides insulation. However, air also allows convection, which can increase heat transfer if it can circulate freely.

Is thermal conductivity the same in all directions?
No. Materials like wood, graphite, and fiber‑reinforced composites are anisotropic – they conduct heat better along one axis than another. For example, graphite conducts about 2000 W/(m·K) in the plane of its layers but only about 10 W/(m·K) perpendicular to them. When calculating k, you must specify the direction relative to the material’s structure.

Related

Formula used
in f | Heat flow Q | W | 50 | 0
in L | Thickness L | m | 0.01 | 0
in A | Area A | m^2 | 0.01 | 0
in dt | Temperature difference ΔT | K | 20 | 0
out k | Thermal conductivity | W/(m·K) | f * L / (A * dt) | 3

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →