molecalculator

Moles & Molar Mass

Carrier Concentration in P-Type Semiconductors

Calculator No. 01-5371 · Updated · Formula and assumptions shown below

Hole concentration p 9.000 × 1015 cm^-3
Electron concentration n
11,111.111 cm^-3
= Intrinsic carrier concentration ni^2 ÷ Hole concentration p
Fermi level relative to valence-band edge EF-Ev
0.1823 eV
Result, rounded to 4 decimal places
Acceptor concentration NA
10000000000000000 cm^-3
Set in the form below
You enter
Acceptor concentration NA (cm^-3), Donor concentration ND (cm^-3), Valence-band effective density of states Nv (cm^-3), Intrinsic carrier concentration ni (cm^-3), Temperature (K)
You get
Hole concentration p (cm^-3), Electron concentration n (cm^-3), Fermi level relative to valence-band edge EF-Ev (eV)
Rounding
3 dp · 4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

Carrier concentration in a p-type semiconductor is the number of mobile holes per unit volume, usually reported in cm−3 or m−3. This calculator estimates the equilibrium hole concentration from acceptor and donor concentrations, temperature, and the material’s effective density of states, using charge neutrality and Fermi–Dirac carrier statistics.

Formula

For a nondegenerate semiconductor at thermal equilibrium, the calculator uses charge neutrality together with the mass-action relation. The first output is p, the hole concentration:

p − n = NA − ND and pn = ni2, so p = [(NA − ND) + √((NA − ND)2 + 4ni2)] / 2.

  • p and n are hole and electron concentrations in cm−3.
  • NA is the concentration of acceptor dopants and ND is the concentration of donor dopants, both in cm−3.
  • ni is the intrinsic carrier concentration in cm−3 for the chosen semiconductor and temperature.
  • Nv is the valence-band effective density of states in cm−3, used for the Fermi-level estimate.
  • EF − Ev = kBT ln(Nv/p). In the calculator, kBT is represented in eV by 8.617333262 × 10−5 eV/K multiplied by temperature in kelvin; the displayed expression uses its 300 K value, 0.025851999786 eV.

The calculator’s Fermi-level output is therefore valid at 300 K, the default temperature. For a different temperature, use 8.617333262 × 10−5T ln(Nv/p) eV. The hole-concentration expression itself does not explicitly use temperature; temperature dependence enters through the material-specific ni and, where relevant, incomplete dopant ionization.

Worked Example

Using the defaults, NA = 1.0000 × 1016 cm−3, ND = 1.0000 × 1015 cm−3, Nv = 1.0400 × 1019 cm−3, and ni = 1.0000 × 1010 cm−3.

First calculate the net dopant concentration: NA − ND = 9.0000 × 1015 cm−3. Then apply charge neutrality and the mass-action relation:

p = [9.0000 × 1015 + √((9.0000 × 1015)2 + 4(1.0000 × 1010)2)] / 2.

The intrinsic-carrier term is tiny compared with the square of the net doping, so p ≈ 9.0000 × 1015 cm−3; to three significant figures the calculator reports 9.000 × 1015 cm−3. The minority-electron concentration is n = ni2/p ≈ 1.111 × 104 cm−3. At 300 K, the Fermi-level estimate is 0.025851999786 ln(1.0400 × 1019 / 9.0000 × 1015) ≈ 0.1819 eV above the valence-band edge.

Assumptions

  • The semiconductor is in thermal equilibrium and is nondegenerate, so Boltzmann carrier statistics apply.
  • All acceptors and donors are treated as ionized. The input concentrations are net-relevant dopant concentrations, not measured mobile-carrier counts.
  • The supplied intrinsic concentration and effective density of states correspond to the same material and temperature. The default values are illustrative, not universal material constants.
  • The Fermi-level output uses the 300 K thermal-energy factor; use the temperature-adjusted formula given above if temperature differs.

What Carrier Concentration Means

Semiconductors conduct through mobile electrons in the conduction band and holes in the valence band. A hole is a useful description of an unoccupied valence-band state that behaves like a positively charged mobile carrier. In p-type material, acceptor doping makes holes the majority carriers; electrons remain present as minority carriers.

Concentration is a count per volume, not a percentage of atoms and not the dopant concentration itself. For example, 1016 cm−3 means about ten million billion carriers in each cubic centimetre. Since one cubic metre contains 106 cubic centimetres, multiply a value in cm−3 by 106 to express it in m−3.

How Doping Sets the Hole Density

An acceptor atom can accept an electron from the valence band, leaving a mobile hole. Donor atoms contribute electrons and compensate some acceptors. When acceptors greatly outnumber donors and are fully ionized, the useful approximation is p ≈ NA − ND. This is why net doping, rather than acceptor concentration alone, often predicts the majority-carrier density.

The approximation is not reliable near intrinsic conditions, where thermally generated electron–hole pairs matter. The quadratic expression used by the calculator includes this effect and remains positive even when donors exceed acceptors. In an n-type sample with strong donor excess it gives a small hole concentration, rather than a negative, physically meaningless result.

At equilibrium, pn = ni2. Thus, increasing the majority-hole population generally reduces the minority-electron population for a fixed ni. This relation is called the mass-action law; it is not a statement that each hole is paired with a particular electron.

Temperature, Material, and Measurement

Temperature affects carrier concentration through the semiconductor’s band gap, effective density of states, and dopant ionization. At low temperatures, some dopants may not be fully ionized (the freeze-out regime). At moderate temperatures, extrinsic doping can dominate. At sufficiently high temperatures, intrinsic thermal generation can overwhelm the dopant contribution. The boundaries depend on the material and dopant, so there is no one temperature range that applies to every sample.

The default ni and Nv are illustrative values often associated with silicon near room temperature; precise values depend on the reference data and temperature. For a quantitative result, enter values appropriate to the actual semiconductor and conditions. The calculator estimates equilibrium carrier density, not conductivity: conductivity also depends on carrier mobility, which can change with doping, temperature, defects, and scattering.

Carrier concentration can be inferred experimentally by methods such as Hall-effect measurements, but measured values may reflect compensation, nonuniform doping, contacts, and measurement conditions. A nominal dopant concentration from a fabrication process is not automatically equal to the measured hole concentration.

Common Misconceptions and Limits

  • P-type does not mean only holes exist. Electrons remain present as minority carriers.
  • Acceptor concentration is not always the hole concentration. Donor compensation, incomplete ionization, and intrinsic generation can make the values differ.
  • More doping does not make the simple model exact. At very high doping, band-gap narrowing and degeneracy can invalidate the nondegenerate relations used here.
  • Concentration alone does not determine resistance. Mobility and sample geometry are also important.

For degenerate material, strongly temperature-dependent ionization, or spatially varying doping, a more complete semiconductor model is needed. This calculator is a compact equilibrium estimate, not a substitute for device simulation or measurement.

Frequently Asked Questions

What is the majority carrier in a p-type semiconductor?
Holes are the majority carriers. Electrons are minority carriers, although their concentration is not zero.

How do you calculate hole concentration from doping?
If acceptors are fully ionized and dominate, use p ≈ NA − ND. Near intrinsic conditions, use charge neutrality with pn = ni2, as in the calculator.

Is hole concentration equal to acceptor concentration?
Only approximately when acceptors are fully ionized, donors do not significantly compensate them, and intrinsic carriers are negligible. Otherwise the concentrations differ.

What are the units of carrier concentration?
Common units are cm−3 and m−3. To convert from cm−3 to m−3, multiply by 106.

Does temperature change the hole concentration?
Yes. Temperature changes intrinsic carrier generation and dopant ionization. Use material properties appropriate to the temperature; room-temperature defaults should not be treated as universal.

Related

Formula used
in na | Acceptor concentration NA | cm^-3 | 1e16 | 0
in nd | Donor concentration ND | cm^-3 | 1e15 | 0
in nv | Valence-band effective density of states Nv | cm^-3 | 1.04e19 | 0
in ni | Intrinsic carrier concentration ni | cm^-3 | 1e10 | 0
in t | Temperature | K | 300 | 0
out p | Hole concentration p | cm^-3 | (na - nd + sqrt((na - nd)^2 + 4 * ni^2)) / 2 | 3
out n | Electron concentration n | cm^-3 | ni^2 / p | 3
out ef | Fermi level relative to valence-band edge EF-Ev | eV | 0.025851999786 * ln(nv / p) | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →