molecalculator

Moles & Molar Mass

First-Order Chemical Kinetics Formula and Calculator

Calculator No. 01-6529 · Updated · Formula and assumptions shown below

Concentration at time t [A]t 0.0549 mol/L
Fraction remaining
0.5488
Result, rounded to 4 decimal places
Half-life
69.3147 s
Result, rounded to 4 decimal places
Initial concentration [A]0
0.1 mol/L
Set in the form below
You enter
Initial concentration [A]0 (mol/L), First-order rate constant k (s^-1), Elapsed time t (s)
You get
Concentration at time t [A]t (mol/L), Fraction remaining, Half-life (s)
Rounding
4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The first-order chemical kinetics formula is ln([A]t/[A]0) = −kt, or equivalently [A]t = [A]0e−kt. This calculator uses the initial concentration, rate constant, and elapsed time to find the remaining concentration of a reactant in a first-order reaction.

Formula

For a reactant A disappearing by a first-order reaction, its rate of consumption is proportional to its current concentration:

−d[A]/dt = k[A]

Integrating this rate law gives the concentration form used by the calculator:

[A]t = [A]0e−kt

  • [A]t is the reactant concentration after time t, in mol/L.
  • [A]0 is the concentration at the chosen starting time, in mol/L.
  • k is the first-order rate constant, in s−1 when time is entered in seconds.
  • t is elapsed time, in seconds.
  • e is the base of the natural logarithm.

The equivalent logarithmic expression is ln([A]t/[A]0) = −kt. The rate constant and time must use reciprocal, matching units: if k is in min−1, enter time in minutes, or convert k to s−1 before using seconds. The calculator’s rate-constant input is labeled s−1.

Worked Example

Using the calculator defaults, let [A]0 = 0.100 mol/L, k = 0.0100 s−1, and t = 60 s.

  1. Calculate the dimensionless exponent: −kt = −(0.0100 s−1)(60 s) = −0.60000.
  2. Calculate the remaining concentration: [A]t = (0.100 mol/L)e−0.60000 = 0.054881 mol/L, which rounds to 0.0549 mol/L at four decimal places.
  3. Calculate the fraction remaining: e−0.60000 = 0.54881, or about 54.88%.
  4. Calculate the half-life: t1/2 = ln(2)/(0.0100 s−1) = 69.315 s, or 69.3151 s to four decimal places.

Assumptions

  • The reaction follows a single, constant first-order rate law over the time interval considered.
  • The entered rate constant applies under the reaction’s actual conditions, including temperature and medium.
  • The concentration is represented by a well-mixed bulk value; the calculation does not account for changing volume, transport limits, or competing reactions.

How First-Order Kinetics Works

“First order” describes how the reaction rate depends on reactant concentration. If the concentration doubles while other relevant conditions remain fixed, the instantaneous rate doubles. It does not mean that the reaction takes one step or that the concentration falls by the same absolute amount in every equal time interval. Instead, it loses the same fraction over each equal interval.

For example, if a first-order process has a half-life of 10 minutes, a starting amount of 100 units becomes 50 after 10 minutes, 25 after 20 minutes, and 12.5 after 30 minutes, assuming the first-order model remains valid. The absolute amount lost gets smaller, but each interval removes half of what was present at its start.

A plot of ln([A]) against time is a straight line for ideal first-order behavior. Its slope is −k, and its vertical intercept is ln([A]0). This is a common way to assess whether measured concentration-time data are consistent with first-order kinetics and to estimate the rate constant.

Half-Life and Useful Rearrangements

The half-life is the time needed for the concentration to fall to half its initial value. Substituting [A]t = [A]0/2 into the integrated equation gives t1/2 = ln(2)/k. Because [A]0 cancels, the half-life for a first-order reaction does not depend on the starting concentration, provided k stays constant.

The same equation can be rearranged to find a missing variable:

  • Rate constant: k = ln([A]0/[A]t)/t.
  • Elapsed time: t = ln([A]0/[A]t)/k.
  • Fraction remaining: f = [A]t/[A]0 = e−kt.

These rearrangements require a positive elapsed time and a remaining concentration greater than zero and no greater than the initial concentration for a simple decay process. Measurements that appear to show an increase, or a negative concentration, are not explained by this model without additional chemistry or measurement effects.

When to Use the Formula and Its Limits

Use the formula when evidence or a stated problem identifies the disappearance of a reactant as first order and you know its rate constant under the relevant conditions. It is useful for predicting concentration at a later time, estimating a half-life, or checking how much reactant remains. It can also describe an observed first-order process that is more complex at the molecular level, such as a pseudo-first-order reaction when another reactant is present in large excess.

The rate constant is not universal for a substance: it can change with temperature, solvent, pressure, catalysts, and other conditions. A value measured under one set of conditions should not automatically be applied to another. For temperature-dependent studies, rate constants are often related through the Arrhenius equation, but this calculator assumes k is already known and constant.

Real data may not follow a single first-order law. Multiple reaction pathways, reversible reactions, changing conditions, or a mixture of species can produce curves that do not fit the simple exponential equation. A good fit over a limited time range does not prove that the mechanism is a single elementary step.

Common Mistakes

  • Mixing time units: k in s−1 must be paired with time in seconds. A numerical answer can be badly wrong if minutes are entered without conversion.
  • Using common logarithms in place of natural logs: the integrated expression uses ln. If using log10, include the conversion factor 2.303.
  • Confusing rate with rate constant: the instantaneous rate changes as [A] changes; k remains constant only while conditions and the applicable model remain the same.
  • Assuming equal amounts disappear in equal intervals: first-order decay removes equal fractions, not equal absolute concentrations.
  • Rounding too early: keep extra digits through the exponential calculation and round the final concentration to match the precision of the inputs and measurements.

For bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.

Frequently Asked Questions

What is the formula for a first-order reaction?
The integrated concentration formula is [A]t = [A]0e−kt. Its logarithmic form is ln([A]t/[A]0) = −kt.

What are the units of a first-order rate constant?
The units are inverse time, such as s−1 or min−1. Use a time unit that matches the rate constant.

How do you calculate first-order half-life?
Use t1/2 = ln(2)/k, with k expressed in inverse units of the desired time. For k in s−1, the half-life comes out in seconds.

Does first-order half-life depend on initial concentration?
No. In the ideal first-order model, initial concentration cancels when the half-life is derived. The rate constant must still remain applicable under the conditions being considered.

How can I tell whether a reaction is first order?
Compare concentration-time data with the integrated rate laws. A straight line in ln([A]) versus time, with a reasonably constant slope, is consistent with first-order behavior, though it does not by itself establish a reaction mechanism.

Related

Formula used
in a0 | Initial concentration [A]0 | mol/L | 0.100 | 0
in k | First-order rate constant k | s^-1 | 0.0100 | 0
in t | Elapsed time t | s | 60 | 0
out at | Concentration at time t [A]t | mol/L | a0 * exp(-k * t) | 4
out frac | Fraction remaining | - | exp(-k * t) | 4
out half | Half-life | s | ln(2) / k | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →