Serial dilution is a step-by-step method of diluting a solution by a constant factor (for example, 1:10, 1:100, 1:1000) each time, and in A level biology it is used to prepare a range of known concentrations from a stock solution, often to count cells, measure enzyme activity, or produce a calibration curve. You take a small volume from the previous dilution, add it to a fresh volume of diluent (usually water or buffer), mix, and repeat until you have the desired range of concentrations. This article explains the maths, the practical steps, common mistakes, and how to interpret the results in the context of A level biology practicals.
Formula
The dilution factor for one step is the total volume after mixing divided by the volume of stock transferred:
Dilution factor per step = (volume transferred + diluent volume) / volume transferred
For a 1 mL sample added to 9 mL diluent, the factor is (1 + 9)/1 = 10, so it is a 1 in 10 dilution. After n identical steps, the overall dilution factor is that per-step factor raised to the power of n:
Overall dilution factor = (per-step factor)n
The concentration after n steps is the original concentration divided by the overall dilution factor:
Cfinal = Cinitial / (per-step factor)n
Where:
- Cinitial – concentration of the stock solution (mol/L, g/L, cells/mL, etc.)
- v0 – volume of solution transferred each step (mL)
- vd – volume of diluent added each step (mL)
- n – number of dilution steps (a whole number)
Worked Example
Suppose you have a 1.0 mol/L stock solution. You transfer 1 mL into 9 mL of diluent, mix, then transfer 1 mL of that mixture into a fresh 9 mL diluent, and repeat three times total.
Step 1: dilution factor = (1 + 9)/1 = 10. Concentration after step 1 = 1.0 / 10 = 0.1 mol/L.
Step 2: dilution factor = 10 again. Concentration = 0.1 / 10 = 0.01 mol/L.
Step 3: dilution factor = 10 again. Concentration = 0.01 / 10 = 0.001 mol/L.
Overall dilution factor = 103 = 1000. Final concentration = 1.0 / 1000 = 0.001 mol/L.
The calculator above gives exactly that: df = 1000 and cf = 0.001 mol/L.
Assumptions
- Each step is mixed thoroughly so the transferred volume is representative.
- The volumes are measured accurately (using a pipette and volumetric flask or graduated pipette).
- The diluent does not react with the solute or change its activity.
- The solution is dilute enough that the density change is negligible (for most biological buffers this holds).
- Each step uses a fresh pipette tip or the same pipette is rinsed to avoid carry-over.
Why Serial Dilution Is Used in A Level Biology
Directly diluting a stock to a very low concentration, say 1 part per million, would require measuring tiny volumes (e.g. 1 µL into 1 L) that are impractical and error-prone. Serial dilution avoids that by making a series of manageable steps. It also produces a set of concentrations that are evenly spaced on a logarithmic scale, which is exactly what you need for:
- Counting viable bacteria or yeast cells by plating dilutions and counting colonies.
- Estimating cell density using a haemocytometer (dilute so cells are not overlapping).
- Constructing a calibration curve for colorimetry or spectrophotometry (e.g. protein assay, glucose assay).
- Determining the effect of concentration on enzyme activity or reaction rate.
- Finding the minimum inhibitory concentration (MIC) of an antibiotic or disinfectant.
How to Choose the Dilution Factor and Number of Steps
The choice depends on the starting concentration and the range you need. A common factor is 10 (1 mL into 9 mL) or 2 (1 mL into 1 mL). For cell counting, you often want a final count of 30–300 colonies per plate, so you estimate the original cell density and work backwards. For a calibration curve, you want 5–7 points spanning the expected unknown range.
Example: if your stock is 5.0 mol/L and you need concentrations from 0.5 to 0.005 mol/L, a 10-fold dilution series gives 0.5, 0.05, 0.005 – three points, but you might want more. A 2-fold series from 0.5 would give 0.25, 0.125, 0.0625, 0.03125, 0.0156, 0.0078 – many more points but each step is small. The number of steps n is simply the number of times you repeat the transfer.
Common Mistakes and Misconceptions
- Forgetting to mix – if you don’t mix after adding diluent, the transferred volume is not uniform, and the next dilution is wrong.
- Using the same pipette tip without rinsing – this carries over concentrated solution, increasing the concentration of the next dilution.
- Confusing dilution factor with dilution ratio – a 1:10 dilution means 1 part sample + 9 parts diluent, not 1 part sample + 10 parts diluent. The total volume is 10 parts.
- Assuming the final volume is the solvent volume – when you add 1 mL to 9 mL, the final volume is 10 mL, not 9 mL. The formula uses total volume.
- Rounding too early – if you round each step to 2 decimal places, errors accumulate. Keep extra digits in your calculations and round at the end.
- Thinking serial dilution is the same as a simple dilution – a simple dilution is one step; serial dilution is multiple steps, and the concentration drops exponentially.
Comparing Serial Dilution with Direct Dilution
Direct dilution (also called single dilution) is one step: you take a volume of stock and add diluent to a final volume. For example, to get 0.1 mol/L from 1.0 mol/L, you could take 10 mL of stock and add water to 100 mL. That is straightforward but only gives one concentration. To get a range of concentrations, you would need to do many separate direct dilutions, each requiring a different volume of stock – that is tedious and uses more stock. Serial dilution uses a small amount of stock and produces a geometric series of concentrations with minimal effort. The downside is that errors propagate: if you make a mistake in step 2, it affects all subsequent steps. Direct dilution errors are independent for each concentration.
Practical Tips for the Lab
- Label each tube clearly with the dilution factor (e.g. 10-1, 10-2) before you start.
- Use a fresh pipette tip for each transfer, or rinse the tip with the solution you are about to transfer.
- Mix by vortexing or by pipetting up and down at least 5 times.
- Work quickly but carefully – evaporation can change concentrations.
- For cell counts, plate each dilution in duplicate or triplicate to account for variability.
Frequently Asked Questions
How do I calculate the concentration after a serial dilution?
Use the formula: final concentration = initial concentration / (dilution factor per step)n. For example, starting at 2.0 mol/L, doing 4 steps of 1:10 dilution gives 2.0 / 104 = 0.0002 mol/L.
What is a 1 in 10 serial dilution?
It means each step you take 1 part of the previous solution and add 9 parts of diluent, making a 10-fold dilution each time. After 3 steps, the original is diluted 1000-fold.
Why do I need a serial dilution for a calibration curve?
A calibration curve requires several known concentrations that cover the range of your unknown samples. Serial dilution gives you a set of concentrations that are evenly spaced on a log scale, which is ideal for many assays, and it is quicker than making each concentration separately.
What is the difference between a dilution series and a serial dilution?
A dilution series is any set of different concentrations prepared from a stock. A serial dilution is a specific method of making that series by repeated dilution of the previous solution. All serial dilutions produce a dilution series, but a dilution series can also be made by direct dilution.
How do I count bacteria using serial dilution?
You perform a serial dilution of the bacterial culture, plate a known volume (e.g. 0.1 mL) from each dilution onto agar, incubate, count colonies on plates with 30–300 colonies, then multiply by the dilution factor and the volume plated to get the original cell density (CFU/mL).
Does serial dilution affect pH or buffer capacity?
Diluting a buffer changes its concentration, which can shift pH slightly and reduce buffer capacity. In enzyme assays, you usually dilute in the assay buffer to maintain pH and ionic strength. Always check the pH after dilution if it matters.
Safety and Good Practice
Always follow your lab method, the safety data sheet (SDS) and your supervisor. When working with microorganisms, use aseptic technique and disinfect surfaces. When handling chemicals, wear appropriate PPE (gloves, goggles, lab coat). Never pipette by mouth. Dispose of biological waste as instructed.
Related
Formula used
in c0 | Initial concentration | mol/L | 1.0 | 0 in v0 | Volume transferred | mL | 1 | 0 in vd | Diluent volume per step | mL | 9 | 0 in n | Number of dilution steps | - | 3 | 1 out df | Overall dilution factor | - | (v0 + vd) / v0 * n | 0 out cf | Final concentration | mol/L | c0 / ((v0 + vd) / v0)^n | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution Calculation Examples0.2000 mol/L
- Serial Dilution: How It Works & Why It Matters1.000 × 10−5 mol/L
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL
- Serial Dilution Factor: How to Calculate It