molecalculator

Moles & Molar Mass

Constant Volume Specific Heat of Air: Value and Calculation

Calculator No. 01-5614 · Updated · Formula and assumptions shown below

Heat transferred at constant volume 7,180 J
Mass of air
1 kg
Set in the form below
Temperature change
10 K
Set in the form below
Specific heat at constant volume
718 J/(kg·K)
Set in the form below
You enter
Mass of air (kg), Temperature change (K), Specific heat at constant volume (J/(kg·K))
You get
Heat transferred at constant volume (J)
Rounding
0 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The constant-volume specific heat of dry air, usually written as cv, is about 718 J/(kg·K) near room temperature; this is a practical approximate value, not a universal constant. This calculator estimates the heat required for a specified mass of air undergoing a temperature change at fixed volume: enter its mass, temperature change, and specific heat, and it returns heat transfer in joules.

Formula

The constant-volume heat relation is Q = m cv ΔT. Here, Q is heat transferred in joules (J), m is air mass in kilograms (kg), cv is mass-specific heat capacity at constant volume in J/(kg·K), and ΔT is the final temperature minus the initial temperature in kelvins (K). A temperature difference has the same numerical size in kelvins and degrees Celsius. Positive Q means heat enters the air under this sign convention; negative Q means heat leaves it.

The calculator uses the selected value of 718 J/(kg·K) as an approximate room-temperature value for dry air. It does not convert pressure, volume, or temperature into another state: those conditions and the chosen heat capacity are assumptions supplied by the user or stated here.

Worked Example

For the defaults, the air mass is 1 kg, the temperature change is 10 K, and the assumed constant-volume specific heat is 718 J/(kg·K).

Q = m cv ΔT
Q = (1 kg)(718 J/(kg·K))(10 K)
Q = 7180 J

The units kg and K cancel, leaving joules. To the calculator’s displayed precision, the result is 7180 J, or 7.180 kJ. This is an estimate based on a constant heat capacity over the full 10 K interval.

Assumptions

  • Air is treated as dry air with an approximate, constant specific heat of 718 J/(kg·K).
  • The process occurs at fixed volume, and the air is modeled as an ideal gas for interpreting the thermodynamic distinction.
  • The calculation is a heat-capacity estimate. It excludes heat losses, work by moving boundaries, changes in composition, and other effects not represented by Q = m cv ΔT.

What Constant-Volume Specific Heat Means

Specific heat capacity measures how much energy is needed to raise the temperature of a unit mass by one degree. The subscript v indicates that the relevant heat capacity is measured for a process at constant volume. For air, its value near ordinary room conditions is commonly approximated as 0.718 kJ/(kg·K), or 718 J/(kg·K).

Specific heat is not the same as total heat. The heat required also depends on how much air is present and how far its temperature changes. For example, under the same simplified assumptions, 2 kg of air heated by 10 K would require roughly twice the energy of 1 kg heated by 10 K. The calculator expresses this proportional relationship directly.

Values found in references may differ slightly because heat capacity depends on temperature, air composition, humidity, and the conventions or precision used in a table. The stated value is useful for many introductory calculations, but precision-sensitive engineering work should use data appropriate to the actual conditions.

Why cv Differs from cp

Air also has a constant-pressure specific heat, cp, approximately 1005 J/(kg·K) near room temperature. It is larger than cv, which is roughly 718 J/(kg·K). The distinction matters because, when a gas warms at constant pressure, it expands and does work on its surroundings. At fixed volume, there is no expansion work from a moving boundary, so less heat is needed for the same temperature rise in the idealized comparison.

For an ideal gas, the mass-specific heat capacities are related by cp − cv = Rspecific. For dry air, the specific gas constant is about 287 J/(kg·K), consistent with the approximate values above. This relationship is for ideal-gas behavior; real-air properties and reference values can vary with temperature and composition.

A frequent mistake is to use the familiar 1005 J/(kg·K) value in a problem explicitly asking for a constant-volume change. That value is normally associated with constant pressure. Conversely, for ordinary atmospheric heating where air can expand freely, using cv may not describe the actual process.

Using the Calculator and Reading the Result

Enter mass in kilograms, temperature change in kelvins (or the numerically equivalent Celsius difference), and the appropriate cv in J/(kg·K). The default mass and temperature change are simple examples; replace them with values from the problem. The specific-heat field is editable so a temperature-appropriate value from a reliable property reference can be used.

  • For warming, enter a positive temperature change; the result is positive heat input.
  • For cooling, enter a negative temperature change; the result is negative, indicating heat leaving the air.
  • If the mass is given in grams, divide it by 1000 to convert to kilograms before entering it.
  • If specific heat is provided in kJ/(kg·K), multiply it by 1000 to convert it to J/(kg·K).

Do not confuse a temperature difference with an absolute temperature. A change from 20 °C to 30 °C is 10 K, not 303.15 K. Also distinguish mass from volume: a volume of air cannot be entered as though it were kilograms. To get mass from volume, additional information such as pressure, temperature, and air density is needed.

Limits and Common Calculation Problems

The formula assumes that the chosen heat capacity represents the whole temperature interval. Since specific heat varies with temperature, a large temperature range may require integrating temperature-dependent heat capacity or using an average value from a suitable table. Humid air is a mixture whose properties differ from dry air, so 718 J/(kg·K) may not be suitable when humidity is significant.

Constant volume is a process condition, not simply a label for a container. A rigid, sealed vessel is a common approximation, but real systems can exchange heat with walls or lose mass through leaks. The equation estimates the energy associated with the air’s temperature change; it does not calculate wall heating, energy needed to heat equipment, or losses to the environment.

For an ideal gas in a rigid closed container, the relation between pressure and absolute temperature can also be useful: at fixed volume and fixed amount of gas, pressure is proportional to temperature in kelvins. That relationship does not replace the heat calculation, and Celsius temperatures must not be used directly in the proportionality.

Frequently Asked Questions

What is the constant-volume specific heat of air?
For dry air near room temperature, a commonly used approximate value is 718 J/(kg·K), equivalent to 0.718 kJ/(kg·K). Its exact value varies with conditions and the data source.

Is the specific heat of air 718 or 1005 J/(kg·K)?
Both are common approximate values, but they refer to different conditions: about 718 J/(kg·K) is cv, while about 1005 J/(kg·K) is cp, the constant-pressure value.

Can I use Celsius in the calculation?
Yes, if you enter a temperature difference. A change of 10 °C is numerically equal to 10 K. Do not enter an absolute Celsius temperature where a temperature change is required.

How much heat raises 1 kg of air by 1 K at constant volume?
Using 718 J/(kg·K), the estimate is 718 J. This follows directly from Q = m cv ΔT with 1 kg and a 1 K change.

Does the value change with temperature or humidity?
Yes. Heat capacity varies with temperature, and moist air has different properties from dry air. For accurate work, use property data matching the actual temperature and air composition.

Related

Formula used
in m | Mass of air | kg | 1 | 0
in dt | Temperature change | K | 10 | -
in cv | Specific heat at constant volume | J/(kg·K) | 718 | 0
out q | Heat transferred at constant volume | J | m * cv * dt | 0

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →