To convert a heat-transfer coefficient from BTU/(h·ft²·°F) to W/(m²·°C), multiply the value by 5.678263. This calculator converts the input coefficient directly and reports the equivalent value in watts per square metre per degree Celsius.
Formula
The conversion is:
W/(m²·°C) = BTU/(h·ft²·°F) × 5.678263337
Here, u is the numerical input in British thermal units per hour per square foot per degree Fahrenheit, and w is the converted numerical value in watts per square metre per degree Celsius. The conversion factor combines the unit conversions for energy, time, area, and temperature interval:
- 1 international-table BTU = 1055.05585262 J.
- 1 hour = 3600 s.
- 1 ft² = 0.09290304 m².
- A temperature difference of 1 °F = 5/9 °C.
In unit-factor form, the calculation is 1055.05585262 J per BTU ÷ 3600 s per hour ÷ 0.09290304 m² per ft² × 9/5. The result is 5.678263337 W/(m²·°C) for each 1 BTU/(h·ft²·°F). The calculator displays four decimal places.
Worked Example
Using the calculator’s default input of 1 BTU/(h·ft²·°F):
- Start with 1 BTU/(h·ft²·°F).
- Multiply by the conversion factor: 1 × 5.678263337 = 5.678263337 W/(m²·°C).
- Round to the calculator’s four decimal places: 5.6783 W/(m²·°C).
For another example, 4.5 BTU/(h·ft²·°F) × 5.678263337 = 25.5521850165 W/(m²·°C), or 25.5522 W/(m²·°C) to four decimal places. Keep the unrounded factor for calculations where precision matters, then round the final result to a precision appropriate for the source data.
Assumptions
- The input is a heat-transfer coefficient expressed in BTU per hour, square foot, and degree Fahrenheit—not a total heat flow or thermal conductivity.
- The BTU is the international-table BTU, equal to 1055.05585262 J.
- Temperature units describe a temperature difference or interval. Celsius and Fahrenheit absolute temperatures do not convert by multiplying by this factor.
- The conversion changes units only; it does not change the physical meaning, measurement conditions, or accuracy of the input.
What This Unit Measures
BTU/(h·ft²·°F) and W/(m²·°C) are units commonly used for a heat-transfer coefficient. The coefficient describes heat flow per unit area for each degree of temperature difference across a boundary or assembly. A larger value means more heat passes through per area for the same temperature difference, under the stated conditions.
It is not the same quantity as thermal conductivity, which is typically measured in W/(m·K). Conductivity describes a material property per thickness; a heat-transfer coefficient describes heat transfer across a surface or through a combined construction, often including surface effects. Nor is it a heat-flow rate in watts: to calculate a rate, the coefficient must be combined with an area and a temperature difference, and the relevant model must be known.
Why the Temperature Factor Matters
The energy, time, and area conversions are not the only parts of the factor. A Fahrenheit degree is smaller than a Celsius degree: a temperature interval of 1 °F equals 5/9 °C. Therefore, a value expressed per Fahrenheit degree must be multiplied by 9/5 when rewritten per Celsius degree. Ignoring this change gives a result that is too small by a factor of 1.8.
This interval conversion is different from converting a temperature reading. For absolute temperatures, °C = (°F − 32) × 5/9; the offset of 32 does not apply to a temperature difference. For instance, a temperature gap of 18 °F is a gap of 10 °C. Heat-transfer coefficients use the gap, so their conversion uses the interval ratio rather than an offset.
How to Use the Conversion
Enter the number as it appears in the source, in BTU/(h·ft²·°F). The calculator multiplies it by 5.678263337 and shows the converted coefficient. The input can be zero or positive; a negative coefficient would usually indicate a sign convention or data-entry issue rather than a standard positive heat-transfer coefficient.
- Check that the source unit includes both area and temperature difference.
- Do not enter a value in BTU/h alone; that is a heat-flow rate and needs different units and information.
- Retain more digits during intermediate calculations than you plan to report.
- When comparing published values, check whether they describe the same construction, surface conditions, and measurement method.
Common Mix-Ups and Comparisons
A frequent mistake is to convert only BTU to joules, or only square feet to square metres, while leaving the hour or Fahrenheit interval unchanged. The full factor handles all four units together. Another error is to use 5/9 instead of 9/5 for the temperature part: converting a value stated “per °F” to one stated “per °C” requires 9/5.
The Celsius and kelvin interval sizes are identical: a change of 1 °C equals a change of 1 K. Accordingly, the numerical value in W/(m²·K) is the same as in W/(m²·°C). This equality applies to temperature differences in the denominator, not to absolute temperature readings. If a source instead uses a non-international BTU definition, its conversion factor may differ slightly; use the definition specified by that source when exact comparability is essential.
Frequently Asked Questions
How many W/(m²·°C) are in 1 BTU/(h·ft²·°F)?
One BTU/(h·ft²·°F) equals 5.678263337 W/(m²·°C), or approximately 5.6783 at four decimal places.
How do I convert W/(m²·°C) back to BTU/(h·ft²·°F)?
Divide the value in W/(m²·°C) by 5.678263337. For example, 10 W/(m²·°C) is about 1.761 BTU/(h·ft²·°F).
Is W/(m²·K) the same as W/(m²·°C)?
Yes, for a heat-transfer coefficient the denominator represents a temperature interval. One kelvin of change and one Celsius degree of change are equal in size.
Does this convert thermal conductivity?
No. Thermal conductivity is generally expressed in W/(m·K), with length rather than area in the denominator. This conversion is for a coefficient in BTU/(h·ft²·°F).
Why is the Fahrenheit-to-Celsius factor 9/5 here?
The coefficient is stated per Fahrenheit degree. Since 1 °C of temperature difference equals 1.8 °F, a value per °F becomes 1.8 times as large when expressed per °C.
Related
Formula used
in u | Value in BTU per hour per square foot per °F | BTU/(h·ft²·°F) | 1 | 0 out w | Value in W per square metre per °C | W/(m²·°C) | u * 5.678263337 | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Calculator in Hindi: Meaning, Usage and Examples0.2000 mol/L
- Volume Strength Formula in Terms of Molarity11.20 volumes
- H2O2 Volume Strength to Molarity Calculator0.893 mol/L
- Volume Strength to Molarity: Formula and Calculator0.0409 mol/L
- Molar Volume: Definition, Formula, and Calculator22.414 L/mol
- Molar Volume of a Gas Calculator and Formula22.4140 L/mol