molecalculator

Moles & Molar Mass

Cv to Kv Calculator: Convert Valve Flow Coefficients

Calculator No. 01-4637 · Updated · Formula and assumptions shown below

Flow coefficient Kv 0.8650 m3/h/sqrt(bar)
Equivalent Cv
1.0000 US gpm/sqrt(psi)
= Flow coefficient Kv ÷ 0.864966
Flow coefficient Cv
1 US gpm/sqrt(psi)
Set in the form below
You enter
Flow coefficient Cv (US gpm/sqrt(psi))
You get
Flow coefficient Kv (m3/h/sqrt(bar)), Equivalent Cv (US gpm/sqrt(psi))
Rounding
4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

A Cv-to-Kv calculator converts a valve’s flow coefficient from Cv to Kv, or from Kv to Cv. Enter either coefficient; the calculator returns the equivalent value using the standard conversion factor.

Formula

The conversion is Kv = 0.864966 × Cv. To convert in the other direction, use Cv = Kv ÷ 0.864966, or multiply Kv by approximately 1.1561.

  • Cv is the valve flow coefficient in US gallons per minute (US gpm) at a pressure drop of 1 pound per square inch (psi), under the coefficient’s standard reference conditions.
  • Kv is the metric flow coefficient in cubic metres per hour (m³/h) at a pressure drop of 1 bar.
  • 0.864966 is the conversion factor between these conventional coefficient units.

The calculator accepts Cv as its input and displays the corresponding Kv first, followed by the reverse-converted Cv as a check. Since the output is a coefficient, it does not calculate a valve’s actual flow under your operating conditions.

Worked Example

Using the default input, Cv = 1:

  1. Apply the conversion: Kv = 0.864966 × Cv.
  2. Substitute the value: Kv = 0.864966 × 1 = 0.864966 m³/h/√bar.
  3. Round to four decimal places: Kv = 0.8650.
  4. Check by converting back: Cv = 0.864966 ÷ 0.864966 = 1.0000.

For another example, a valve coefficient of Cv = 10 corresponds to Kv = 8.64966, or 8.6497 to four decimal places. Conversely, Kv = 10 corresponds to Cv ≈ 11.561.

Assumptions

  • This is a unit conversion between conventional Cv and Kv coefficient definitions; it does not model an installation.
  • The coefficients are compared using their stated reference units: US gpm and psi for Cv, and m³/h and bar for Kv.
  • The output’s four decimal places are for display. Keep additional precision during further calculations when it matters.

What Cv and Kv Measure

Cv and Kv describe a valve’s capacity to pass fluid for a given pressure difference. A larger coefficient generally indicates greater flow capacity under comparable conditions. Cv is commonly used with US customary units; Kv is the corresponding metric convention. Both are coefficient values, not flow rates by themselves.

Their definitions refer to water under specified standard conditions. In practical valve sizing, the flow that results from a coefficient also depends on factors such as pressure drop, fluid density or specific gravity, temperature, valve opening, and the valve’s flow characteristics. Gas and steam calculations require additional treatment, including compressibility and the possibility of choked flow. A simple Cv-to-Kv conversion does not account for those effects.

How to Use the Conversion

  • If a specification gives Cv, enter that value to obtain Kv.
  • If a specification gives Kv but a calculation or document requires Cv, use Kv ÷ 0.864966. The reverse-converted Cv output is provided for this purpose.
  • Keep track of which coefficient convention the source uses. Do not label a converted value with the wrong unit system.
  • Compare coefficients only when the valve rating, test basis, and application are sufficiently compatible.

The calculator allows zero as an input, which converts to zero. Real valves normally have a positive rated capacity, so a zero value usually represents a mathematical boundary rather than a useful valve selection.

Conversion Factor and Unit Differences

The factor follows from the unit definitions and the conventional water-flow basis used for each coefficient. Cv uses US gallons per minute and psi; Kv uses cubic metres per hour and bar. Converting the flow and pressure units together gives approximately 0.864966 Kv per Cv. For routine work, the displayed factor is suitable; for specifications or engineering calculations requiring a particular standard or greater precision, use the factor and definitions required by that governing reference.

A frequent mistake is to convert only the flow units while ignoring the pressure units. Another is to use 0.864966 in the reverse direction. For Cv to Kv, multiply by 0.864966; for Kv to Cv, divide by it. The reciprocal is approximately 1.1561, so the numerical value of Cv is greater than Kv for the same rated capacity.

Limits and Common Misunderstandings

Converting a coefficient does not determine the correct valve size. It also does not mean the valve will pass that many gallons or cubic metres per minute in a particular system: the coefficient’s reference pressure condition is part of its definition, and actual pressure drop may be different.

  • Do not confuse capacity with actual flow. A coefficient is an input to a flow calculation, not the calculated operating flow.
  • Do not assume every fluid behaves like water. Density, viscosity, phase, temperature, and pressure can affect real flow and valve sizing.
  • Do not infer valve performance from coefficient alone. A valve’s opening, trim, characteristic curve, and operating range may matter.
  • Avoid premature rounding. Keep the unrounded coefficient through calculations, then round to the precision appropriate for the specification.

Use the applicable valve-sizing method and manufacturer’s certified data for design decisions. For bench work, follow your lab method, the safety data sheet (SDS) and your supervisor.

Frequently Asked Questions

How do I convert Cv to Kv?
Multiply Cv by 0.864966. For example, Cv = 10 gives Kv = 8.64966, approximately 8.6497.

How do I convert Kv to Cv?
Divide Kv by 0.864966, or multiply by approximately 1.1561. For example, Kv = 10 gives Cv ≈ 11.561.

Is Cv the same as flow rate?
No. Cv is a valve capacity coefficient defined using a reference flow and pressure-drop basis. Actual flow depends on operating conditions and the fluid.

Which is larger, Cv or Kv?
For equivalent ratings, the numerical Cv value is about 1.1561 times Kv, so Cv is generally numerically larger.

Can I use this conversion for gas or steam?
The coefficient unit conversion itself is valid, but it does not calculate gas or steam flow. Sizing those applications requires an appropriate compressible-flow method and relevant operating data.

Related

Formula used
in cv | Flow coefficient Cv | US gpm/sqrt(psi) | 1 | 0
out kv | Flow coefficient Kv | m3/h/sqrt(bar) | cv * 0.864966 | 4
out cvback | Equivalent Cv | US gpm/sqrt(psi) | kv / 0.864966 | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →