molecalculator

Moles & Molar Mass

Diameter Thermal Expansion Formula

Calculator No. 01-8810 · Updated · Formula and assumptions shown below

Diameter change (Δd) 0.0480 mm
New diameter
50.0480 mm
= Original diameter + Diameter change (Δd)
Original diameter
50 mm
Set in the form below
Linear expansion coefficient (α)
0.000012 1/°C
Set in the form below
You enter
Original diameter (mm), Linear expansion coefficient (α) (1/°C), Temperature change (ΔT) (°C)
You get
Diameter change (Δd) (mm), New diameter (mm)
Rounding
4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The diameter thermal expansion formula calculates how much an object’s diameter changes with temperature: Δd = d₀ × α × ΔT, where Δd is the change in diameter, d₀ is the original diameter, α is the coefficient of linear thermal expansion, and ΔT is the temperature change. Enter the original diameter, the material’s expansion coefficient, and the temperature change to get the new diameter and the total change.

Formula

The linear thermal expansion formula applied to a diameter is:

Δd = d₀ × α × ΔT

where:

  • Δd = change in diameter (same unit as d₀, e.g., mm)
  • d₀ = original diameter (mm, m, inches, etc.)
  • α = coefficient of linear thermal expansion (1/°C or 1/K)
  • ΔT = temperature change = Tfinal − Tinitial (°C or K)

The new diameter is simply d = d₀ + Δd. Because α is per degree, the same numeric value works for Celsius and Kelvin (a 1 °C change equals a 1 K change). For most engineering metals, α is on the order of 10⁻⁶ to 10⁻⁵ per °C.

Worked Example

Using the calculator defaults: a steel rod with an original diameter of 50 mm, α = 12 × 10⁻⁶ /°C (typical for mild steel), heated by 80 °C.

  1. Δd = 50 mm × 0.000012 /°C × 80 °C
  2. Δd = 50 × 0.000012 = 0.0006 mm per °C
  3. 0.0006 × 80 = 0.048 mm
  4. New diameter = 50 + 0.048 = 50.048 mm

The calculator shows Δd = 0.0480 mm and new diameter = 50.0480 mm. Even with a large temperature swing, the change is under a tenth of a millimeter—this is why thermal fits are so precise.

Assumptions

  • The material is isotropic (expands equally in all directions).
  • The temperature change is uniform across the object.
  • α is constant over the temperature range (true for modest ranges; for very wide ranges, α varies).
  • The object is free to expand—no external constraints.
  • No phase change occurs (e.g., melting or transformation).

When to Use the Diameter Formula

Use this formula whenever you need the change in a circular cross-section—shafts, pipes, holes, bearings, or discs—due to temperature. It is the same as the linear formula, but applied to the diameter dimension. In practice, you often need the new diameter to check clearances or interference fits. For example, a steel shaft at 20 °C inserted into a hole at 80 °C will have a different fit than at room temperature.

The formula also applies to the inner diameter of a hole. A hole expands as if it were a solid disc of the same material, so the same α applies. This is a common point of confusion—people think a hole might shrink when heated, but it actually grows.

How to Choose the Right Coefficient (α)

The coefficient of linear thermal expansion is a material property. It is usually given in units of 1/°C or μm/(m·°C) (which is numerically the same as 10⁻⁶ /°C). Common values at room temperature:

  • Aluminum: ~23 × 10⁻⁶ /°C
  • Steel (mild): ~12 × 10⁻⁶ /°C
  • Stainless steel: ~16 × 10⁻⁶ /°C
  • Copper: ~17 × 10⁻⁶ /°C
  • Glass (borosilicate): ~3 × 10⁻⁶ /°C
  • Concrete: ~10 × 10⁻⁶ /°C

Always use the α value for the specific alloy or material, not a generic “steel” value, because differences between alloys can be 30% or more. For precise work, refer to the material datasheet or a handbook. If the temperature range is large, α changes with temperature; use the average α over that range.

Common Mistakes and Misconceptions

  • Confusing diameter with radius: The formula works for any linear dimension, but if you measure radius, use radius in the formula. Don’t mix them.
  • Using area expansion for diameter: The area expansion coefficient is approximately 2α, but that’s for area, not diameter. For diameter, use α directly.
  • Forgetting to convert units: α is per °C, and ΔT must be in °C or K. If you use °F, convert first (ΔT in °F × 5/9 = ΔT in °C).
  • Thinking a hole shrinks when heated: As noted, a hole expands with the material. The inner diameter increases with temperature.
  • Ignoring the sign of ΔT: If temperature drops, ΔT is negative, so Δd is negative—the diameter shrinks.

Limits of the Formula

The linear approximation works well for small temperature changes and for most structural materials up to a few hundred degrees. For very large temperature swings (e.g., cryogenic to red-hot), α is not constant, and the formula becomes inaccurate. In such cases, engineers use polynomial fits of α(T) or integrate the expansion. Also, the formula assumes the object is free to expand; if it’s constrained, internal stresses develop, and the actual dimensional change is less than predicted. For anisotropic materials (like wood or composites), expansion differs by direction, and a single α is insufficient.

Practical Example: Shrink Fit

A common application is a shrink fit: heating a steel collar (inner diameter 100 mm) to slide over a shaft. If the collar is heated from 20 °C to 120 °C (ΔT = 100 °C), with α = 12 × 10⁻⁶ /°C:

Δd = 100 × 0.000012 × 100 = 0.12 mm

The inner diameter becomes 100.12 mm, allowing clearance over a shaft that is 100.05 mm. When the collar cools, it contracts and grips tightly. The same calculation is used for bearing fits, turbine assemblies, and railway wheels.

Frequently Asked Questions

Does the diameter expansion formula differ from the length expansion formula?

No. The linear expansion formula applies to any linear dimension—length, width, height, diameter, or radius. The change in diameter is simply the original diameter times α times ΔT. The same α value is used.

What is the coefficient of thermal expansion for steel?

Mild steel has α ≈ 12 × 10⁻⁶ /°C, but stainless steel is around 16 × 10⁻⁶ /°C. Always check the specific alloy. Values are typically given at 20 °C and may vary with temperature.

How do I convert α from 1/°F to 1/°C?

Since a 1 °C change equals 1.8 °F, α in 1/°C = α in 1/°F × 1.8. For example, α = 6.7 × 10⁻⁶ /°F becomes 12 × 10⁻⁶ /°C.

Does a hole expand or contract when heated?

A hole expands when heated. The material around the hole expands outward, increasing the inner diameter. The same α applies to the hole’s diameter as to the solid material.

Can I use this formula for a sphere’s diameter?

Yes, the diameter of a sphere expands linearly with temperature. The volume expansion coefficient is approximately 3α, but the diameter change uses α directly.

Why is the change so small?

Because α is typically 10⁻⁵ or 10⁻⁶ per °C, a 1-meter steel bar changes only about 12 micrometers per °C. For a 50 mm diameter, 80 °C change gives only 0.048 mm—enough to matter in precision engineering but invisible to the naked eye.

Related

Formula used
in d | Original diameter | mm | 50 | 0
in a | Linear expansion coefficient (α) | 1/°C | 0.000012 | 0
in dt | Temperature change (ΔT) | °C | 80 | 0
out dd | Diameter change (Δd) | mm | d * a * dt | 4
out dn | New diameter | mm | d + dd | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →