Calculator No. 01-10357 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The effective thermal conductivity equation calculates the overall heat transfer through a composite material or system, accounting for the individual conductivities and volume fractions of its components. You enter the thermal conductivity of each phase and its volume fraction, and the calculator returns the effective conductivity (in W/m·K) based on a selected mixing model (series, parallel, or Maxwell–Eucken).

Formula

The effective thermal conductivity depends on how the phases are arranged. For a composite with two phases, the three most common models are:

  • Series (isostress): keff = 1 / (f1/k1 + f2/k2)
  • Parallel (isostrain): keff = f1k1 + f2k2
  • Maxwell–Eucken (dispersed spheres): keff = k1 · [2k1 + k2 − 2(k1 − k2)f2] / [2k1 + k2 + (k1 − k2)f2]

Where:

  • keff = effective thermal conductivity (W/m·K)
  • k1 = thermal conductivity of phase 1 (W/m·K)
  • k2 = thermal conductivity of phase 2 (W/m·K)
  • f1 = volume fraction of phase 1 (dimensionless, 0 to 1)
  • f2 = volume fraction of phase 2 (dimensionless, = 1 − f1)

The series model represents layers perpendicular to heat flow; the parallel model represents layers parallel to heat flow. The Maxwell–Eucken model assumes phase 2 is isolated spheres dispersed in a continuous phase 1.

Worked Example

Using the default values: k1 = 0.6 W/m·K (e.g., a polymer), k2 = 0.025 W/m·K (air), f1 = 0.5, and the Maxwell–Eucken model.

First, f2 = 1 − 0.5 = 0.5.

Numerator: 2(0.6) + 0.025 − 2(0.6 − 0.025)(0.5) = 1.2 + 0.025 − 2(0.575)(0.5) = 1.225 − 0.575 = 0.650.

Denominator: 2(0.6) + 0.025 + (0.6 − 0.025)(0.5) = 1.2 + 0.025 + 0.575(0.5) = 1.225 + 0.2875 = 1.5125.

keff = 0.6 × (0.650 / 1.5125) = 0.6 × 0.42975 = 0.2579 W/m·K.

The calculator rounds to 0.2579 W/m·K. For comparison, the series model gives 1 / (0.5/0.6 + 0.5/0.025) = 1 / (0.8333 + 20) = 0.04799 W/m·K, and the parallel model gives 0.5×0.6 + 0.5×0.025 = 0.3125 W/m·K. Notice the series result is far lower because the air layer dominates.

Assumptions

  • Steady-state heat conduction with no convection or radiation.
  • Phases are isotropic and homogeneous.
  • Perfect thermal contact between phases (no interfacial resistance).
  • For Maxwell–Eucken, phase 2 is dilute, spherical, and non-interacting.
  • Volume fractions sum to 1.

When to Use Each Model

Choosing the right model is the most important step. The series and parallel models give the theoretical lower and upper bounds for any two-phase composite. Real materials fall between these bounds.

  • Series applies to laminated or layered structures where heat must pass through each layer in sequence, like insulation panels with alternating solid and air layers.
  • Parallel applies to structures where heat can flow through the best conductor without crossing the other phase, such as aligned fibers in a matrix.
  • Maxwell–Eucken is best for particle-filled composites, foams, and porous materials where one phase is a continuous matrix and the other is isolated inclusions. For example, a polymer foam with air bubbles is well described by this model when the air fraction is below about 30%.

For higher filler fractions, the Maxwell–Eucken model underestimates conductivity because particles start touching. In that case, consider the Bruggeman or effective medium approximation, which accounts for percolation.

How to Read the Result

The effective conductivity tells you how well the composite conducts heat as a single homogeneous material. A lower value means better insulation. For example, still air has k ≈ 0.025 W/m·K, while typical building insulation (fiberglass or foam) has k ≈ 0.04 W/m·K. If you add a solid filler to a polymer, the effective conductivity rises, which is why thermal interface materials use high-conductivity fillers like alumina or boron nitride.

The result is an average property. It does not tell you the temperature distribution or heat flux; those require solving the heat equation with boundary conditions. But once you have keff, you can compute the heat flux through a slab using Fourier’s law: q = keff × ΔT / L, where ΔT is the temperature difference and L is the thickness.

Common Mistakes and Limitations

  • Using volume fraction instead of mass fraction: The models require volume fractions. If you have mass fractions, convert using densities: fi = (mi/ρi) / Σ(mj/ρj).
  • Forgetting that f2 = 1 − f1: The calculator does this for you, but when doing hand calculations, always check that the fractions sum to 1.
  • Using the wrong model: The series model gives a much lower result than the parallel model for the same inputs. Know your material’s microstructure.
  • Ignoring temperature dependence: Thermal conductivity of most materials varies with temperature. The equation assumes a constant value at a given temperature.
  • Applying to anisotropic materials: These models assume isotropic phases. For oriented fibers or crystals, you need a tensor description.

Real-World Examples

Consider a composite made of epoxy (k = 0.2 W/m·K) with 20% by volume of copper particles (k = 400 W/m·K). Using Maxwell–Eucken with phase 1 = epoxy, phase 2 = copper, f2 = 0.2:

keff = 0.2 × [2(0.2) + 400 − 2(0.2 − 400)(0.2)] / [2(0.2) + 400 + (0.2 − 400)(0.2)]

= 0.2 × [0.4 + 400 + 159.92] / [0.4 + 400 − 79.96]

= 0.2 × 560.32 / 320.44 = 0.2 × 1.7486 = 0.3497 W/m·K.

Even with 20% copper, the conductivity only increases from 0.2 to about 0.35 W/m·K because the copper particles are isolated. This illustrates why thermal interface materials need high filler loadings (often >50%) to achieve high conductivity.

Another example: a foam insulation with 95% air (k = 0.025) and 5% solid polymer (k = 0.2). Using Maxwell–Eucken with phase 1 = air, phase 2 = polymer, f2 = 0.05:

keff = 0.025 × [2(0.025) + 0.2 − 2(0.025 − 0.2)(0.05)] / [2(0.025) + 0.2 + (0.025 − 0.2)(0.05)]

= 0.025 × [0.05 + 0.2 + 0.0175] / [0.05 + 0.2 − 0.00875]

= 0.025 × 0.2675 / 0.24125 = 0.025 × 1.1088 = 0.0277 W/m·K.

The foam conducts barely more than air, which is why it insulates well.

Frequently Asked Questions

What is the difference between effective and apparent thermal conductivity?

Effective thermal conductivity accounts for all heat transfer mechanisms (conduction, convection, radiation) within a heterogeneous material, treating it as a homogeneous medium. Apparent thermal conductivity is the same concept but is often measured under specific conditions (e.g., a given temperature difference) and may include edge effects. In practice, they are used interchangeably, but effective conductivity is the theoretical value, while apparent is the measured one.

Can I use this equation for liquids or gases?

Yes, the equation is purely based on conductivity and volume fraction, so it works for any phases. However, for liquids and gases, convection can dominate if the pore size is large. The equation assumes conduction only, so it works for small pores (less than about 1 mm) where convection is suppressed, like in fine foams or aerogels.

Why does the series model give a much lower result than parallel?

In the series model, heat must pass through every layer, so the lowest-conductivity layer acts as a bottleneck. In the parallel model, heat can bypass the low-conductivity phase entirely by flowing through the high-conductivity phase. Real composites are between these bounds, and the Maxwell–Eucken model gives a more realistic intermediate value.

How do I convert volume fraction to weight fraction?

Use the densities: fvol,i = (wi/ρi) / Σ(wj/ρj), where wi is the weight fraction and ρi is the density. For example, a composite with 10 wt% carbon fiber (ρ = 1.8 g/cm³) in epoxy (ρ = 1.2 g/cm³) has a volume fraction of fiber = (0.1/1.8) / (0.1/1.8 + 0.9/1.2) = 0.0556 / (0.0556 + 0.75) = 0.069, or 6.9 vol%.

What is the thermal conductivity of air at room temperature?

Air at 25°C and atmospheric pressure has a thermal conductivity of about 0.025 W/m·K. It is one of the best insulators among common materials, which is why foams and aerogels trap air in small pores to achieve low conductivity.

Related

Formula used
in m | Conductivity of phase 1 (k1) | W/m·K | 0.6 | 0 | 1000
in n | Conductivity of phase 2 (k2) | W/m·K | 0.025 | 0 | 1000
in v | Volume fraction of phase 1 (f1) | - | 0.5 | 0 | 1
sel model | Mixing model | Series=1, Parallel=2, Maxwell-Eucken=3
out keff | Effective thermal conductivity | W/m·K | model == 1 ? 1 / (v / m + (1 - v) / n) : model == 2 ? v * m + (1 - v) * n : m * (2 * m + n - 2 * (m - n) * (1 - v)) / (2 * m + n + (m - n) * (1 - v)) | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section