The integrated equation for first-order kinetics is [A]t = [A]0e−kt, where [A]0 is the initial concentration, [A]t is the concentration after time t, and k is the first-order rate constant. This calculator uses an initial concentration, rate constant, and elapsed time to calculate the remaining concentration.
Formula
The calculator applies the integrated first-order rate law:
[A]t = [A]0e−kt
- [A]t is the concentration remaining at time t, in mol/L.
- [A]0 is the concentration at time zero, in mol/L.
- k is the first-order rate constant, in s−1 when time is entered in seconds.
- t is elapsed time, in seconds.
- e is Euler’s number, approximately 2.71828.
The exponent kt must be dimensionless: the time unit used for t must match the time denominator in k. If k is reported in min−1, use time in minutes, or convert one of the values before calculation. The fraction remaining is e−kt; multiplying it by the initial concentration gives the remaining concentration.
The differential form is d[A]/dt = −k[A]. It says that the rate of disappearance at any instant is proportional to the amount of A present. Integrating this rate equation from the starting concentration to the concentration at time t produces the exponential expression above.
Worked Example
Using the calculator’s defaults, [A]0 = 1 mol/L, k = 0.1 s−1, and t = 10 s:
- Calculate the dimensionless product kt: 0.1 s−1 × 10 s = 1.
- Find the fraction remaining: e−1 = 0.367879.
- Multiply by the initial concentration: 1 mol/L × 0.367879 = 0.3679 mol/L, rounded to four decimal places.
- Find the half-life: ln(2) / 0.1 s−1 = 6.9315 s.
After 10 seconds, the predicted concentration is 0.3679 mol/L, and approximately 36.79% of the initial concentration remains.
Assumptions
- The reaction or process follows first-order kinetics over the time interval being considered.
- The first-order rate constant is constant during that interval.
- The entered concentration represents the reacting species whose disappearance is being modeled.
- Concentration and rate constant units are consistent, and time is nonnegative.
What First-Order Kinetics Means
“First order” describes how the rate depends on concentration: if the concentration of A doubles while other relevant conditions remain unchanged, its instantaneous disappearance rate doubles. It does not mean that the reaction takes one step, nor does it say that the reaction is necessarily elementary. An observed first-order rate law can describe a more complex process under particular conditions.
For a first-order disappearance, the same fraction is lost in equal time intervals, not the same absolute amount. For example, a process with a half-life of 5 minutes goes from 100% to 50% in the first 5 minutes, then from 50% to 25% in the next 5. The amount lost in the second interval is smaller, even though the fraction lost is again one-half.
Half-Life and Other Useful Forms
The first-order half-life follows by setting [A]t = [A]0/2 in the integrated equation. Rearranging gives t1/2 = ln(2)/k. Because [A]0 does not appear in this result, the ideal first-order half-life is independent of starting concentration.
Taking the natural logarithm of the integrated rate law gives ln([A]t) = ln([A]0) − kt. Thus a plot of ln concentration against time is a straight line for ideal first-order behavior; its slope is −k, and its intercept is ln([A]0). A related form, ln([A]0/[A]t) = kt, is useful when calculating how long it takes to reach a specified concentration.
For instance, if k is 0.1 s−1, the half-life is about 6.93 s regardless of whether the initial concentration is 1 mol/L or 2 mol/L, provided the first-order model and constant conditions apply. This is a prediction of the model, not proof that a real reaction follows it.
When to Use the Equation
Use the equation to estimate the concentration remaining after a known time, calculate a half-life from a known rate constant, or compare measured concentration changes with a first-order model. It applies to disappearance of a reactant or another measurable quantity when the observed rate is proportional to its concentration. The same mathematics can describe processes beyond chemical reactions, such as radioactive decay, but the meaning and units of the modeled quantity must be appropriate.
- For concentration after a time: enter [A]0, k, and t; read [A]t.
- For a percentage remaining: use the fraction remaining and multiply by 100.
- For half-life: use the calculated half-life output, or calculate ln(2)/k.
- For a target concentration: rearrange to t = ln([A]0/[A]t)/k, with [A]0 greater than [A]t for a positive elapsed time.
The model approaches zero but does not predict a negative concentration. A displayed value that rounds to zero may still represent a small positive calculated value. For practical measurements, uncertainty and detection limits matter: an instrument may stop distinguishing the remaining amount from zero long before the mathematical expression does.
Common Mistakes and Limits
The most common calculation error is mixing time units. A rate constant of 0.2 min−1 must be paired with time in minutes; entering 30 seconds as 30 alongside that rate constant produces a wrong exponent. Convert 30 seconds to 0.5 minutes, or convert k to seconds−1 first. Also distinguish the rate constant k from the reaction rate: k has units of inverse time, while the rate of concentration change has concentration-per-time units.
Another misconception is that an exponential-looking result establishes first-order behavior. To assess order, use concentration measurements across time and evaluate whether ln[A] versus t is approximately linear, considering measurement uncertainty and whether conditions stayed comparable. A changing temperature, changing mechanism, or substantial depletion of a required co-reactant can make a single constant-k model inappropriate.
This calculator treats the supplied k as constant and calculates the concentration of one modeled species. It does not determine k from experimental data, account for reversible reactions or multiple reaction pathways, or infer a reaction mechanism. If the model is being applied to bench work, follow your lab method, the safety data sheet (SDS), and your supervisor.
Frequently Asked Questions
What is the equation for first-order kinetics?
The integrated rate law is [A]t = [A]0e−kt. The differential form is d[A]/dt = −k[A].
What are the units of the first-order rate constant?
Its units are inverse time, such as s−1 or min−1. Use a time unit consistent with the one used for k.
How do you calculate the half-life of a first-order reaction?
Use t1/2 = ln(2)/k. If k is in s−1, the half-life is in seconds.
Does first-order half-life depend on initial concentration?
No. Under the first-order model with a constant rate constant, t1/2 depends on k, not [A]0.
How can I tell whether a reaction is first order?
Measure concentration at multiple times and check whether a plot of ln[A] against time is approximately linear. A straight line supports the model but does not, by itself, establish a mechanism.
Related
Formula used
in a0 | Initial concentration [A]0 | mol/L | 1 | 0 in k | First-order rate constant k | 1/s | 0.1 | 0 in t | Elapsed time t | s | 10 | 0 out at | Concentration remaining [A]t | mol/L | a0 * exp(-k * t) | 4 out frac | Fraction remaining | - | exp(-k * t) | 4 out half | Half-life | s | ln(2) / k | 4
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution Calculation Examples0.2000 mol/L
- Serial Dilution: How It Works & Why It Matters1.000 × 10−5 mol/L
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL