The equation for a serial dilution is the same dilution formula used for any single dilution: C1V1 = C2V2, applied stepwise. In a serial dilution, you take a volume (V1) from a more concentrated solution (C1), add it to a diluent to reach a new total volume (V2), and the resulting concentration is C2; you then repeat that process using the new solution as the starting point for the next step. Each step is an identical dilution factor, so the overall concentration after n steps is the initial concentration multiplied by (dilution factor)−n.
Formula
The core relationship for one dilution step is:
C1V1 = C2V2
- C1 = concentration of the starting (stock) solution (mol/L, g/L, %, etc.)
- V1 = volume of the stock solution you transfer (mL, µL, etc.)
- C2 = concentration of the diluted solution after mixing
- V2 = final total volume after adding diluent (V1 + volume of diluent)
For a serial dilution, the same C1V1 = C2V2 is applied repeatedly. If each step transfers the same volume into the same final volume, the dilution factor D = V2/V1 is constant. After n steps:
Cfinal = Cinitial / Dn
where D is the dilution factor per step (e.g., 10 for a 1:10 dilution), and n is the number of steps.
Worked Example
Using the calculator defaults: start with a 1.0 mol/L stock, perform a 10-fold serial dilution (D = 10) for 3 steps.
- Step 1: C2 = 1.0 / 10 = 0.1 mol/L
- Step 2: take 1 mL of the 0.1 mol/L solution, add 9 mL diluent → C2 = 0.1 / 10 = 0.01 mol/L
- Step 3: take 1 mL of the 0.01 mol/L solution, add 9 mL diluent → C2 = 0.01 / 10 = 0.001 mol/L
Using the formula: Cfinal = 1.0 / (103) = 1.0 / 1000 = 0.001 mol/L. The calculator shows 0.0010 mol/L (4 decimal places) and a total dilution of 1000×.
Assumptions
- Each step is mixed thoroughly before the next transfer.
- The diluent volume is added to reach the final volume V2; the formula uses final volume, not added volume.
- Volumes are additive (valid for most aqueous solutions at moderate concentrations).
- The stock is homogeneous and at the stated concentration.
How to Choose the Dilution Factor and Number of Steps
Serial dilutions are used when you need a range of concentrations spanning several orders of magnitude, such as for standard curves, cell counting, or microbiology plating. The choice of factor and steps depends on the target concentration and the precision you need.
- Determine the total dilution needed: divide the starting concentration by the desired final concentration. For example, from 1 mol/L to 1 µmol/L is a 106-fold dilution.
- Pick a per-step factor: common factors are 2, 5, 10, or 100. A 10-fold (1:10) dilution is standard because it is easy to compute and pipette.
- Calculate the number of steps: n = log(total dilution) / log(factor). For a 106 dilution with 10-fold steps, n = 6.
- Keep volumes practical: transferring 1 mL into 9 mL is easier and more accurate than transferring 10 µL into 90 µL. Avoid transferring less than 1 µL, as pipette error becomes significant.
Common Mistakes and How to Avoid Them
- Confusing final volume with added diluent: In a 1:10 dilution, you add 1 part stock to 9 parts diluent to get 10 parts total. Adding 1 mL stock to 10 mL diluent gives a 1:11 dilution, not 1:10.
- Not mixing between steps: If the solution is not homogeneous, the transferred volume may not contain the expected amount of solute.
- Carrying over pipette tips: Always use a fresh tip for each transfer to avoid contaminating the stock or the next tube.
- Rounding too early: Keep intermediate values with at least three significant figures. Round only the final answer.
- Using the wrong unit: Ensure C1 and C2 are in the same concentration unit, and V1 and V2 are in the same volume unit. The formula works with any consistent units.
Serial vs. Single Dilution
A single dilution (e.g., adding 1 mL of stock to 99 mL of diluent) gives one final concentration. A serial dilution gives multiple concentrations in one procedure, which is more efficient when you need a series of standards or when the required dilution is too large to do in one step accurately. For example, a 1:106 dilution in one step would require adding 1 µL of stock to 999,999 µL (about 1 L) of diluent – impractical and prone to error. Doing six 1:10 steps uses small, accurate volumes.
Real-World Applications
- Microbiology: Plating serial dilutions to count viable bacteria (colony-forming units per mL).
- Biochemistry: Preparing protein or DNA standards for a standard curve, e.g., BCA assay or qPCR.
- Clinical labs: Titrating antibodies or viruses, such as in ELISA or plaque assays.
- Chemistry: Preparing a series of calibration standards for atomic absorption or UV-Vis spectroscopy.
Limits of the Formula
C1V1 = C2V2 assumes ideal mixing and that volumes are additive. For very concentrated solutions (e.g., >1 M) or non-aqueous solvents, the final volume may not equal the sum of the parts due to molecular interactions; in those cases, use volumetric flasks to measure final volume rather than assuming additivity. Also, the formula does not account for adsorption of solute onto pipette tips or tube walls, which can be significant at very low concentrations (below ~1 nM). Finally, the serial dilution model assumes each step is exactly the same factor; if you change the transfer volume or final volume mid-series, you must recalculate from that point.
Frequently Asked Questions
What is the difference between dilution factor and dilution ratio?
The dilution factor is the ratio of final volume to stock volume (V2/V1). A 1:10 dilution ratio means 1 part stock + 9 parts diluent, giving a dilution factor of 10. In notation, “1:10” often means “1 in 10” (final volume is 10 times the stock volume), but sometimes it is written as “1:10” meaning 1 part to 10 parts total – always check the context.
How do I calculate the concentration after a 2-fold serial dilution?
A 2-fold dilution means D = 2. After n steps, Cfinal = Cinitial / 2n. For example, starting at 100 µg/mL, after 4 steps: 100 / 24 = 100 / 16 = 6.25 µg/mL.
Can I use C1V1 = C2V2 for serial dilutions?
Yes, but you apply it step by step. For each step, solve for V1 (volume to transfer) given C1 (current concentration), C2 (desired concentration after that step), and V2 (final volume of that step). The output of one step becomes the C1 of the next.
Why do I need to mix after each dilution?
Mixing ensures the solution is homogeneous so that the volume you transfer contains the same concentration as the bulk solution. Without mixing, the transferred aliquot may have a different concentration, leading to inaccurate results.
What if I want a final volume that isn’t 10 mL?
That’s fine. The formula works for any volumes. For a 1:10 dilution with a final volume of 5 mL, use V1 = 5/10 = 0.5 mL of stock and add 4.5 mL of diluent. The key is that the ratio V2/V1 equals the dilution factor.
How do I prepare a serial dilution from a stock that is in a different unit?
Convert the stock concentration to the same unit as your desired final concentration before using the formula. For example, if the stock is 5 M and you want 50 mM, convert 5 M to 5000 mM, then use C1V1 = C2V2 to find the first dilution step.
For any bench work, always follow your lab method, the safety data sheet (SDS) and your supervisor.
Related
Formula used
in c1 | Initial concentration | mol/L | 1.0 | 0 in df | Dilution factor per step | - | 10 | 1.0001 in n | Number of steps | - | 3 | 1 out c2 | Final concentration | mol/L | c1 / (df ^ n) | 4 out total | Total dilution | - | df ^ n | 0
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Volume Calculator in Chemistry: How to Use It0.2000 mol/L
- Volume Calculator in mm: Convert & Calculate100,000 mm³
- Volume Calculator: Convert ft to Yards1.00 yd³
- Volume Calculator Feet and Inches: How to Use It3.12 ft³
- Surfboard Volume Calculator JS: How It Works32.4 L
- Volume Calculator cm to Litres: How to Convert2.500 L