molecalculator

Moles & Molar Mass

Expansion Fan Calculator: How to Use It

Calculator No. 01-8816 · Updated · Formula and assumptions shown below

The calculator on this page is switched off while it is checked. The formula is below, and the worked example shows how to do the sum by hand.

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

An expansion fan calculator works out the flow properties (Mach number, pressure, temperature, and flow angle) across a Prandtl–Meyer expansion fan, which forms when a supersonic flow turns around a convex corner. You enter the upstream Mach number, the upstream static pressure and temperature, the flow deflection angle, and the ratio of specific heats (gamma), and the calculator returns the downstream Mach number, pressure, temperature, and the Prandtl–Meyer angle. This page explains the physics, the exact equations, and how to interpret the results for compressible flow problems.

Formula

The expansion fan is analyzed using the Prandtl–Meyer function, which relates the Mach number to the flow angle. For a calorically perfect gas with constant specific heats, the Prandtl–Meyer angle ν(M) is:

ν(M) = √((γ+1)/(γ−1)) · arctan(√((γ−1)/(γ+1)·(M²−1))) − arctan(√(M²−1))

where:

  • M = Mach number (dimensionless)
  • γ = ratio of specific heats (dimensionless, e.g., 1.4 for air)
  • ν = Prandtl–Meyer angle in radians (convert to degrees for display)

Across the fan, the flow turns by angle θ, so the downstream Prandtl–Meyer angle is ν₂ = ν₁ + θ. Then the downstream Mach number M₂ is found by inverting the Prandtl–Meyer function. The pressure and temperature ratios across the fan follow the isentropic relations:

p₂/p₁ = [(1 + (γ−1)/2·M₁²) / (1 + (γ−1)/2·M₂²)]^(γ/(γ−1))

T₂/T₁ = (1 + (γ−1)/2·M₁²) / (1 + (γ−1)/2·M₂²)

These assume an isentropic expansion (no shock, no friction, no heat transfer), which is an excellent approximation for a sharp convex corner in supersonic flow.

Worked Example

Consider air (γ = 1.4) flowing at Mach 2.0 with static pressure 100 kPa and static temperature 300 K. The flow turns 10° around a convex corner. Using the default values from the calculator:

  1. Compute ν₁ for M₁ = 2.0:
    ν₁ = √((1.4+1)/(1.4−1))·arctan(√((1.4−1)/(1.4+1)·(4−1))) − arctan(√(4−1))
    = √6·arctan(√(0.4/2.4·3)) − arctan(√3)
    = 2.4495·arctan(0.7071) − 1.0472 rad
    = 2.4495·0.6155 − 1.0472 = 1.5077 − 1.0472 = 0.4605 rad = 26.38°
  2. Add the turn angle: ν₂ = 26.38° + 10° = 36.38° (0.6350 rad).
  3. Invert the Prandtl–Meyer function to find M₂. Solving numerically gives M₂ = 2.385 (this matches the calculator’s output).
  4. Compute pressure ratio: p₂/p₁ = [(1 + 0.2·4) / (1 + 0.2·2.385²)]^(1.4/0.4) = [1.8 / (1 + 0.2·5.688)]^3.5 = [1.8 / 2.1376]^3.5 = 0.8420^3.5 = 0.5669. Thus p₂ = 100 × 0.5669 = 56.69 kPa.
  5. Compute temperature ratio: T₂/T₁ = 1.8 / 2.1376 = 0.8420. Thus T₂ = 300 × 0.8420 = 252.6 K.

The calculator rounds p₂ to 56.69 kPa and T₂ to 252.6 K, matching the hand calculation.

Assumptions

  • The gas is calorically perfect with constant specific heats (γ constant).
  • The expansion is isentropic: no shock waves, no friction, no heat transfer.
  • The flow is steady, adiabatic, and one-dimensional upstream and downstream of the fan.
  • The corner is sharp and the turn angle is small enough that the fan is fully attached (no separation).
  • Static pressure and temperature are used, not stagnation values.

When to Use an Expansion Fan Calculator

You need this calculator whenever you have a supersonic flow that turns away from itself—around a convex corner, over a boat-tail, or at the trailing edge of an airfoil. Common applications include:

  • Designing supersonic nozzles and wind tunnels.
  • Analyzing flow over airfoils at supersonic speeds.
  • Computing flow properties around spacecraft during re-entry.
  • Understanding the behavior of exhaust plumes from rockets and jets.

The expansion fan is the opposite of an oblique shock: it turns the flow in the direction that increases the Mach number, decreases pressure, temperature, and density. It is an isentropic process, so total pressure and total temperature remain constant across the fan—unlike a shock, which is non-isentropic.

How to Read the Results

The downstream Mach number is always greater than the upstream Mach number because the flow accelerates as it expands. The pressure and temperature drop, often significantly—a 10° turn at Mach 2 drops pressure by about 43% in the example. The Prandtl–Meyer angle itself is a measure of the total turning a flow can achieve before it reaches a given Mach number; as Mach number approaches infinity, ν approaches a maximum value (about 130.45° for γ=1.4).

If your calculated downstream Mach number is less than 1, that indicates the expansion fan is not physically possible because the flow would have to decelerate through a shock—but that cannot happen in a pure expansion. The calculator will show a result, but you should check whether the turn angle is too large for the upstream Mach number. For a given γ, there is a maximum turn angle that still yields a supersonic downstream flow; beyond that, the flow would separate or form a different wave pattern.

Common Mistakes and Misconceptions

  • Using stagnation instead of static values: The Prandtl–Meyer function uses static pressure and temperature. If you enter stagnation values, the output is meaningless.
  • Sign of the turn angle: The expansion fan forms only when the flow turns away from itself (convex corner). If the flow turns into itself, you get an oblique shock, not an expansion fan. The calculator assumes a positive deflection angle for expansion.
  • Degrees vs. radians: The formula uses radians, but most people think in degrees. The calculator handles the conversion, but if you code it yourself, be careful.
  • Gamma variation: For air at standard conditions γ=1.4, but for hot combustion gases γ can be lower (e.g., 1.2–1.3). Using the wrong γ changes the results by several percent.
  • Forgetting the maximum turning angle: For a given M₁, there is a maximum θ beyond which the expansion fan cannot turn the flow to a supersonic Mach number. The calculator will still give a number, but it may not be physically realizable.

Limitations of the Prandtl–Meyer Model

The Prandtl–Meyer theory assumes a perfect gas with constant specific heats. At very high temperatures (above ~2000 K), air dissociates and γ changes, making the results approximate. Real flows also have boundary layers that can cause the effective turning angle to be slightly different from the geometric angle. For small turn angles (<5°) the theory is extremely accurate; for larger angles, it remains good but you should verify with computational fluid dynamics or wind tunnel data. Also, the fan is not a single line but a continuous region of Mach waves; the calculator gives the properties after the fan is complete, not the internal structure.

Frequently Asked Questions

What is the difference between an expansion fan and an oblique shock?

An expansion fan occurs when supersonic flow turns away from itself (convex corner); it is isentropic, increases Mach number, and decreases pressure and temperature. An oblique shock occurs when flow turns into itself (concave corner); it is non-isentropic, decreases Mach number, and increases pressure and temperature. The expansion fan is a smooth, continuous fan of Mach waves, while a shock is a thin discontinuity.

Can I use this calculator for subsonic flow?

No. The Prandtl–Meyer function is defined only for Mach numbers greater than 1. For subsonic flow, a turn produces a gradual change in pressure and velocity without a fan of Mach waves. The calculator enforces a minimum Mach number of 1.0, but you should only use it for genuinely supersonic flows.

What is the maximum expansion angle possible?

For a given γ, the maximum Prandtl–Meyer angle is ν_max = (π/2)·(√((γ+1)/(γ−1)) − 1). For γ=1.4, this is about 130.45°. The maximum turn angle from a given M₁ is ν_max − ν(M₁). For M₁=1, the maximum turn is 130.45°, but in practice the flow would separate or the pressure would drop to zero long before that.

Does the expansion fan change the total pressure?

No. The expansion is isentropic, so total pressure and total temperature remain constant across the fan. This is a key difference from a shock, which reduces total pressure. The static pressure and temperature drop, but the stagnation values stay the same.

How do I find the downstream Mach number if I only know the turn angle?

You need the upstream Mach number to compute ν₁. Then add the turn angle to get ν₂, and invert the Prandtl–Meyer function. The inversion is not a simple algebraic formula; it requires solving a transcendental equation. The calculator does this numerically. For hand calculation, you would use a table of Prandtl–Meyer angles or a root-finding method.

What if my flow has a different gas than air?

Enter the correct ratio of specific heats γ for your gas. For example, helium has γ≈1.67, carbon dioxide at room temperature has γ≈1.29, and steam at high temperature has γ≈1.3. The calculator accepts γ between 1.0 and 1.67. The results are valid for any calorically perfect gas with that γ.

Safety and Practical Notes

This calculator is for educational and engineering design purposes only. If you are conducting experiments with supersonic flows, always follow your lab’s safety procedures and the equipment manufacturer’s guidelines. High-speed flows can produce strong forces and noise; ensure all pressure vessels and wind tunnels are properly rated. For real-world design, verify results with computational fluid dynamics or experimental data, especially for large turning angles or high temperatures.

Related

Formula used
in m1 | Upstream Mach number | - | 2.0 | 1.0 | 10.0
in p1 | Upstream static pressure | kPa | 100.0 | 0.0 | 100000.0
in T1 | Upstream static temperature | K | 300.0 | 50.0 | 5000.0
in theta | Flow deflection angle (turn away from flow) | deg | 10.0 | 0.0 | 90.0
in gamma | Ratio of specific heats | - | 1.4 | 1.0 | 1.67
out nu1 | Prandtl–Meyer angle upstream | deg | sqrt((gamma+1)/(gamma-1))*atan(sqrt((gamma-1)/(gamma+1)*(m1^2-1)))*180/pi - atan(sqrt(m1^2-1))*180/pi | 4
out nu2 | Prandtl–Meyer angle downstream | deg | nu1 + theta | 4
out m2 | Downstream Mach number | - | sqrt(1 + (gamma+1)/(gamma-1)*tan((nu2*pi/180 + atan(sqrt((gamma+1)/(gamma-1)*(m1^2-1)))*180/pi - nu1*pi/180)/2)^2) | 4
out p2 | Downstream static pressure | kPa | p1 * ((1 + (gamma-1)/2*m1^2) / (1 + (gamma-1)/2*m2^2))^(gamma/(gamma-1)) | 2
out T2 | Downstream static temperature | K | T1 * ((1 + (gamma-1)/2*m1^2) / (1 + (gamma-1)/2*m2^2)) | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →