molecalculator

Moles & Molar Mass

First- and Second-Order Kinetics: Rates and Examples

Calculator No. 01-6532 · Updated · Formula and assumptions shown below

Rate constant k 0.0693 s^-1 for first order; L/(mol·s) for second order
Half-life at c0
10.0000 s
Result, rounded to 4 decimal places
Initial concentration
0.1 mol/L
Set in the form below
Concentration at time t
0.05 mol/L
Set in the form below
You enter
Initial concentration (mol/L), Concentration at time t (mol/L), Elapsed time (s), Reaction order
You get
Rate constant k (s^-1 for first order; L/(mol·s) for second order), Half-life at c0 (s)
Rounding
4 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

First-order kinetics means a reaction rate is proportional to the concentration of one reactant; second-order kinetics means the rate is proportional either to the square of one reactant’s concentration or to the product of two reactant concentrations. This calculator uses concentration and time data to estimate the reaction order from how concentration changes, then gives the corresponding rate constant and units.

Formula

For a first-order reaction, the integrated rate law is ln(C0/Ct) = kt, so k = ln(C0/Ct)/t. For a second-order reaction involving one reactant, it is 1/Ct − 1/C0 = kt, so k = (1/Ct − 1/C0)/t. The calculator selects the appropriate expression using the chosen order.

  • C0 is the initial reactant concentration in mol/L.
  • Ct is the concentration after elapsed time t, also in mol/L.
  • t is elapsed time in seconds.
  • k is the rate constant: s−1 for first order and L/(mol·s) for second order.
  • Half-life is the time for the reactant concentration to fall to half its starting value. For first order, t1/2 = ln(2)/k. For second order, t1/2 = 1/(kC0).

The input concentrations must be positive, and the measured concentration must not exceed the initial concentration for the usual disappearance of a reactant. Use one consistent concentration unit and one consistent time unit. This calculator uses mol/L and seconds; if time is entered in minutes instead, the resulting k would be per minute and should not be compared directly with a value in per second.

Worked Example

Using the defaults, C0 = 0.100 mol/L, Ct = 0.050 mol/L, t = 10 s, and first order:

  1. Calculate the concentration ratio: C0/Ct = 0.100/0.050 = 2.
  2. Calculate the first-order rate constant: k = ln(2)/10 s = 0.06931 s−1.
  3. Calculate the first-order half-life: t1/2 = ln(2)/0.06931 s−1 = 10.0000 s.

The result means this sample’s concentration halves in 10 seconds under the selected first-order model. The calculation assumes the measured change can be represented by that model; it does not establish the reaction order by itself.

Assumptions

  • The concentration data describe the disappearance of one reactant over a known elapsed time.
  • The selected rate law applies throughout the measured interval and the rate constant is constant under the experimental conditions.
  • The selected second-order model is the one-reactant form, rate = kC2. A reaction involving two different reactants requires the appropriate rate law and concentration data.
  • Concentrations are positive and expressed in mol/L; time is expressed in seconds.

What Reaction Order Means

A reaction’s order describes how its rate responds to reactant concentration. It is part of the experimentally determined rate law, not usually something that can be read directly from the balanced chemical equation. For example, a first-order rate law for A → products is rate = k[A]. Doubling [A] doubles the instantaneous rate. A second-order law might be rate = k[A]2, in which doubling [A] makes the rate four times as large.

Second order can also mean rate = k[A][B], where the reaction is first order in A and first order in B, and second order overall. The calculator’s second-order option specifically uses the single-reactant form k[A]2; it cannot separately estimate a two-reactant rate law from one concentration measurement. Overall reaction order is the sum of the exponents in the experimentally supported rate law.

How to Identify the Order

One concentration-time pair can produce a value of k under either chosen model. To decide which order better describes a reaction, collect concentration measurements at several times and compare the integrated-rate-law plots:

  • For first order, plot ln[C] against time. A straight line supports first-order behavior; its slope is −k.
  • For second order in one reactant, plot 1/[C] against time. A straight line supports second-order behavior; its slope is +k.
  • Compare the fit quality and inspect residuals rather than relying only on a visually straight line. Consider measurement uncertainty and whether conditions changed during the experiment.

These are integrated forms of the differential rate laws, −d[A]/dt = k[A] and −d[A]/dt = k[A]2. The negative sign indicates that reactant concentration decreases. In either case, k is positive for ordinary reactant disappearance. Bench work should follow the lab method, the safety data sheet (SDS), and the supervisor’s instructions.

Comparing Rates, Units, and Half-Life

The units of k are a useful check, but they do not identify the order on their own. For a first-order process, concentration cancels from the integrated equation, leaving inverse time. For a second-order process, k has inverse-concentration per time units. With mol/L and seconds, those are L/(mol·s). Report the units alongside the numerical value.

A key difference is how half-life changes as a reaction proceeds. In a first-order reaction, t1/2 = ln(2)/k and does not depend on the starting concentration. Successive halvings take equal amounts of time in the ideal model. In a second-order reaction, t1/2 = 1/(kC0), so a higher starting concentration gives a shorter initial half-life. If the concentration is halved, the next half-life is longer.

Common Errors and Limits

  • Assuming order from coefficients: coefficients in an overall balanced equation do not generally prove the measured rate law. Use a mechanism-derived elementary step only where justified, or use experimental data.
  • Mixing units: entering minutes while interpreting k as s−1 causes a factor-of-60 error. Keep the time units consistent.
  • Using one data point as proof: both models can calculate a k from one pair. Multiple measurements and a fit comparison are needed to assess which model is supported.
  • Ignoring conditions: temperature, solvent, catalysts, and other conditions can affect k. Values measured under different conditions may not be comparable.
  • Rounding too early: retain full calculator precision during intermediate steps, then round the reported value to match the precision of the measurements.

The simple forms assume a constant rate constant and a suitable concentration-based rate law. Reversible reactions, changing temperature, multiple pathways, or changing reaction conditions can make a straight-line integrated plot inappropriate. A calculated k is therefore a model-based estimate, not a universal constant for a substance.

Frequently Asked Questions

What is the difference between first- and second-order kinetics?
First-order rate is proportional to one reactant concentration. Second-order rate is proportional to the square of one concentration, or to the product of two concentrations. Their integrated plots, rate-constant units, and half-life behavior differ.

Can reaction order be found from the balanced equation?
Usually not. Reaction order is determined experimentally unless the equation represents a justified elementary step, for which the molecular event can support the corresponding rate law.

What are the units of a first-order rate constant?
They are inverse time, such as s−1 when time is measured in seconds. A second-order constant for rate = k[A]2 has units of inverse concentration per time, such as L/(mol·s).

Does a first-order reaction have a constant half-life?
Yes, for a constant k under the model, its half-life is ln(2)/k regardless of starting concentration. For the one-reactant second-order model, half-life depends on the initial concentration.

Can I determine order from just two concentration measurements?
You can calculate k under an assumed order, but two measurements do not reliably establish which order is correct. Use several time points and compare the linearity and residuals of the appropriate integrated plots.

Related

Formula used
in c0 | Initial concentration | mol/L | 0.100 | 0
in ct | Concentration at time t | mol/L | 0.050 | 0
in t | Elapsed time | s | 10 | 0
sel ord | Reaction order | First order=1, Second order=2
out k | Rate constant k | s^-1 for first order; L/(mol·s) for second order | (ord - 1) * (1 / ct - 1 / c0) / t + (2 - ord) * ln(c0 / ct) / t | 4
out half | Half-life at c0 | s | (2 - ord) * ln(2) / k + (ord - 1) / (k * c0) | 4

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →