First-order kinetics describes a process whose rate is directly proportional to the amount or concentration of one reactant. This calculator uses an initial concentration, a first-order rate constant, and elapsed time to find the remaining concentration and the fraction remaining.
Formula
For a first-order process, the integrated rate law is [A]t = [A]0e−kt. The rate law is −d[A]/dt = k[A] when [A] is a reactant being consumed. The calculator reports the remaining concentration [A]t as its main result.
- [A]0, entered as c0, is the initial concentration in mol/L.
- [A]t, reported as c, is the concentration after time t in mol/L.
- k is the first-order rate constant in s−1.
- t is elapsed time in seconds.
- e is the base of the natural logarithm. The fraction remaining is e−kt; multiplying it by 100 gives percent remaining.
The product kt must be dimensionless, so the time unit and rate-constant unit must match. This calculator uses seconds and s−1; convert minutes or hours to seconds, or convert k to the corresponding inverse-time unit, before entering values.
Worked Example
Using the defaults, c0 = 0.100 mol/L, k = 0.002 s−1, and t = 500 s:
- Calculate the dimensionless exponent: −kt = −(0.002 s−1)(500 s) = −1.
- Find the fraction remaining: e−1 = 0.3678794412.
- Calculate the remaining concentration: c = (0.100 mol/L)(0.3678794412) = 0.03678794412 mol/L, which rounds to 0.0368 mol/L at four decimal places.
- Convert the fraction to a percentage: 100 × 0.3678794412 = 36.78794412%, or 36.79% at two decimal places.
Assumptions
- The process follows a single first-order rate law over the elapsed time.
- The rate constant is constant under the conditions considered.
- Concentration is an appropriate measure of the reacting amount, and the system is sufficiently well mixed for that concentration to represent the sample.
- The calculation predicts a mathematical concentration; it does not account for competing reactions, changing conditions, or measurement uncertainty.
What First-Order Kinetics Means
“First order” refers to how the rate depends on concentration, not to the number of steps in a reaction mechanism or the speed category of a process. If doubling [A] doubles the instantaneous rate while other relevant conditions stay fixed, the observed rate is first order in A. For a simple reaction A → products, the rate is often written −d[A]/dt = k[A]. The minus sign indicates that A is being consumed; the rate of disappearance itself is positive.
Reaction order is determined experimentally from how measured rates change with concentration. It is not always equal to a coefficient in a balanced chemical equation. A complicated reaction can show first-order behavior under particular conditions, and its apparent order may change when conditions or the rate-limiting pathway change.
Common examples of first-order behavior include radioactive decay and some chemical reactions when the relevant reactant concentration controls the rate. These examples share a mathematical pattern, but their physical mechanisms are not necessarily the same. For radioactive decay, the quantity may be the number of undecayed nuclei rather than a solution concentration.
Half-Life and Reading the Result
The half-life is the time required for the concentration to fall to half its starting value. Setting [A]t/[A]0 = 0.5 in the integrated law gives t1/2 = ln(2)/k. For the example k = 0.002 s−1, t1/2 = 346.5736 s, or about 346.6 s. For a first-order process with constant k, this half-life does not depend on the starting concentration.
The remaining fraction is often more useful than the concentration when comparing runs with different initial concentrations. For example, 36.79% remaining means that 63.21% has disappeared, assuming the measured species is consumed and there is no formation of that same species from another pathway. “Percent remaining” is not automatically the same as reaction yield or percent converted in a multistep system.
Finding a Rate Constant from Data
If the initial and later concentrations are known, rearrange the integrated law to calculate the rate constant: k = ln([A]0/[A]t)/t. Concentrations must use the same units, and t must be positive and expressed in the time unit paired with k. A plot of ln[A] against time is linear for ideal first-order behavior; its slope is −k. A plot of concentration itself against time is generally curved, not a straight line.
For experimental data, using one initial and one later measurement can be sensitive to measurement error. Multiple measurements across time can help assess whether a straight-line ln[A] versus time model is reasonable. Systematic curvature may indicate a different order, changing conditions, multiple processes, or measurement issues; it is not proof of any one explanation by itself.
Common Mistakes and Limits
- Mixing time units: enter t in seconds when k is in s−1. For example, 5 minutes is 300 seconds, not 5 seconds.
- Confusing rate and concentration: k has units of inverse time for a first-order law, while the instantaneous disappearance rate has concentration per time.
- Using the wrong logarithm: the integrated expression uses the natural exponential e−kt; when rearranging for k, use the natural logarithm ln.
- Assuming every reaction is first order: first-order behavior must be supported by an appropriate kinetic model or data. Other reactions may be zero order, second order, mixed order, or governed by more complex kinetics.
- Ignoring changing conditions: temperature, catalysts, solvent, and other conditions can affect k. A constant-k calculation is not valid across conditions where the rate constant changes substantially.
The expression gives a positive remaining concentration for nonnegative inputs, but real measurements have limited precision. Keep guard digits during calculations and round only the reported result to a precision justified by the input data. The model also omits reversibility, product inhibition, parallel reactions, and transport limitations unless those effects are negligible or incorporated into an experimentally determined apparent rate constant.
Frequently Asked Questions
What is the equation for first-order kinetics?
The integrated equation is [A]t = [A]0e−kt, where k is the first-order rate constant and t is elapsed time. The differential rate law for disappearance is −d[A]/dt = k[A].
What are the units of a first-order rate constant?
The units are inverse time, such as s−1, min−1, or h−1. Use a time value in the matching unit so kt has no units.
Does first-order half-life depend on initial concentration?
No, not when the process follows a first-order law with a constant k. Its half-life is ln(2)/k, so changing the starting concentration does not change the predicted half-life.
How can I tell whether a reaction is first order?
Measure concentration over time and test whether ln[A] versus time is approximately linear under the chosen conditions. Initial-rate experiments that vary concentration can provide additional evidence. A good fit supports the model but does not, by itself, prove a mechanism.
Does first order mean one reactant molecule is involved?
No. It describes the observed mathematical dependence of rate on concentration. Reaction order is generally determined experimentally and does not necessarily reveal how many molecules participate in an elementary step.
Related
Formula used
in c0 | Initial concentration | mol/L | 0.100 | 0 in k | First-order rate constant | 1/s | 0.002 | 0 in t | Elapsed time | s | 500 | 0 out c | Remaining concentration | mol/L | c0 * exp(-k * t) | 4 out f | Fraction remaining | - | exp(-k * t) | 4 out p | Percent remaining | % | 100 * exp(-k * t) | 2
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- Serial Dilution Calculation Examples0.2000 mol/L
- Serial Dilution: How It Works & Why It Matters1.000 × 10−5 mol/L
- Serial Dilution A Level Biology: How To Do It30
- Serial vs Simple Dilution: Key Differences0.2000 mol/L
- Milton Tablet Dilution: Mixing Guide0.2000 mol/L
- qPCR Serial Dilution Standard Curve: How to Build One100,000 copies/µL