molecalculator

Moles & Molar Mass

Continuous Decay Formula: Equation and Examples

Calculator No. 01-5198 · Updated · Formula and assumptions shown below

Amount remaining 36.7879 units
Fraction remaining
0.3679 fraction
Result, rounded to 4 decimal places
Percent remaining
36.79 %
= 100 × Fraction remaining
Initial amount
100 units
Set in the form below
You enter
Initial amount (units), Decay constant (1/time), Elapsed time (time)
You get
Amount remaining (units), Fraction remaining (fraction), Percent remaining (%)
Rounding
4 dp · 2 dp

For study and lab planning. The result follows from the numbers you enter and the formula shown. Check it against your method before you weigh, mix or dilute anything, follow the safety data sheet and your supervisor, and do not use it for clinical, dosing or medication work.

The continuous decay formula is N(t) = N₀e−kt, where N₀ is the starting amount, k is the continuous decay constant, and t is elapsed time. This calculator finds the amount remaining after a chosen time; enter the initial amount, decay constant, and time, using matching time units.

Formula

The remaining amount under continuous exponential decay is calculated as:

N(t) = N₀e−kt

  • N(t) is the amount remaining after elapsed time t, in the same units as N₀.
  • N₀ is the amount at the start, at t = 0.
  • e is Euler’s number, approximately 2.71828.
  • k is the positive continuous decay constant, in inverse units of time (for example, day−1).
  • t is elapsed time, in the time unit used to define k.

The calculator’s inputs use arbitrary consistent time units: if k is expressed per day, enter t in days; if k is per second, enter seconds. The percentage remaining is 100e−kt. The fraction lost is 1 − e−kt, so the percentage decayed is 100(1 − e−kt).

Worked Example

Using the calculator defaults, the initial amount is 100 units, the decay constant is 0.1 per time unit, and elapsed time is 10 time units.

  1. Multiply the decay constant by the elapsed time: kt = 0.1 × 10 = 1.
  2. Calculate the exponent: e−kt = e−1 ≈ 0.36788.
  3. Find the remaining amount: N(t) = 100 × 0.3678794412 ≈ 36.7879, which rounds to 36.7879 units.
  4. The fraction remaining is approximately 0.3679, and the percentage remaining is 36.79%.

Assumptions

  • The amount follows a single, constant-rate exponential decay process.
  • The decay constant is nonnegative and does not change during the interval.
  • The entered time unit matches the inverse time unit of k.
  • The model treats the amount as continuous; it does not account for random variation or measurement uncertainty.

How Continuous Decay Works

Continuous decay models a quantity whose rate of loss at any instant is proportional to how much remains. In differential-equation form, that assumption is dN/dt = −kN. Its solution is N(t) = N₀e−kt. As the amount gets smaller, the absolute loss per unit time also gets smaller, while the proportion lost over equal time intervals stays the same.

This is different from subtracting a fixed amount at every interval. For example, losing 5 units each hour is linear decay; losing 10% of what remains each hour is exponential decay. A process that loses a fixed percentage once per hour can be modeled discretely as N₀(1 − r)m, where r is the per-interval fraction lost and m is the number of intervals. Continuous decay instead describes a rate acting throughout time. For the same overall change, the continuous rate equivalent to a discrete fraction r per interval is k = −ln(1 − r) per interval.

Half-Life and the Decay Constant

Half-life, t1/2, is the time required for half the initial amount to remain. Set N(t) = N₀/2 in the decay equation and solve to get:

t1/2 = ln(2)/k, or equivalently, k = ln(2)/t1/2.

For instance, if a process has a half-life of 5 days, k = 0.693147… / 5 ≈ 0.13863 day−1. After 15 days, three half-lives have passed, so one-eighth of the starting amount remains: 12.5%. The half-life is independent of the starting amount in this ideal model. This relationship is useful when a source provides half-life rather than a decay constant.

Choosing Inputs and Reading the Result

Use a decay constant measured or specified for the process being modeled. Its numerical value depends on the chosen time unit: a rate stated per hour must not be paired with a time entered in days unless one value is converted. The amount’s units can be grams, molecules, concentration, or another nonnegative quantity, provided the initial and remaining values use the same units.

  • If you know a half-life, convert it with k = ln(2)/t1/2.
  • If you know the starting and remaining amounts after a measured time, estimate k with k = ln(N₀/N(t))/t, provided both amounts are positive and the amount has decreased.
  • If you need the time to reach a target amount, rearrange the formula: t = ln(N₀/N(t))/k.
  • For repeated equal time periods, the remaining fraction after each half-life is halved; after n half-lives, it is (1/2)n.

The calculator returns the remaining amount, its fraction of the starting amount, and the percentage remaining. A result below 1 does not mean the original amount has become negative; exponential decay approaches zero without crossing it. For very long times, the calculated value may be extremely close to zero, and rounding can make it display as zero even though the mathematical model remains positive.

Limits and Common Mistakes

The central assumption is a constant proportional decay rate. A changing environment, multiple decay processes, replenishment, or a process with an initial delay may require a different or more detailed model. In radioactive decay, the equation describes expected activity or the expected number of undecayed nuclei; the actual timing of individual nuclear events is random. In other applications, the model is only as reliable as the rate estimate and the measurements behind it.

  • Mixing time units: Pairing a per-day k with hours makes the exponent incorrect. Convert either the rate or the time first.
  • Using a percentage as k: A 10% loss per interval is not automatically k = 0.10 per interval for continuous decay. For a discrete 10% loss each interval, the equivalent continuous constant is −ln(0.90) per interval.
  • Confusing loss with what remains: e−kt gives the remaining fraction, not the fraction lost.
  • Rounding too early: Keep extra digits in k and intermediate calculations; round only the final result to a precision supported by the input data.
  • Assuming a fitted rate is universal: A rate estimated from one sample or set of conditions may not apply under different conditions.

For an ideal first-order decay process, this equation is the standard model. If observations do not form a straight line when ln(N) is plotted against time, that can signal measurement problems or a mismatch between the data and the single-rate model; it is not a reason to force the formula onto the process.

Frequently Asked Questions

What is the formula for continuous decay?
N(t) = N₀e−kt. Multiply the starting amount by the exponential factor e−kt to find how much remains after time t.

What does k mean in continuous decay?
k is the positive decay constant, or proportional rate of loss. Its unit is the inverse of the time unit, such as day−1 when time is measured in days.

How do I calculate continuous decay from half-life?
First calculate k = ln(2)/t1/2, then use N(t) = N₀e−kt. Keep the half-life and elapsed time in the same units.

Is continuous decay the same as exponential decay?
Continuous decay is commonly modeled by an exponential function. It represents proportional loss continuously over time, while a discrete exponential model applies a repeated change at distinct intervals.

How do I find the percentage that has decayed?
Calculate 100(1 − e−kt). The calculator’s percentage output is the percentage remaining, so subtract it from 100% to get the percentage lost.

Related

Formula used
in n0 | Initial amount | units | 100 | 0
in k | Decay constant | 1/time | 0.1 | 0
in t | Elapsed time | time | 10 | 0
out n | Amount remaining | units | n0 * exp(-k * t) | 4
out f | Fraction remaining | fraction | exp(-k * t) | 4
out p | Percent remaining | % | 100 * f | 2

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →