The formula for thermal conductivity is k = (Q · L) / (A · ΔT), where Q is heat transferred (watts), L is material thickness (meters), A is cross-sectional area (m²), and ΔT is temperature difference (kelvin or °C). This gives k in watts per meter-kelvin (W/(m·K)), a material’s intrinsic ability to conduct heat. Enter the heat flow, thickness, area, and temperature difference below to calculate k directly.
Formula
Thermal conductivity is defined by Fourier’s law of heat conduction in one dimension. The steady-state heat flow through a flat slab is:
Q = k · A · (ΔT / L)
Rearranged to solve for k:
k = (Q · L) / (A · ΔT)
- Q = heat transfer rate (watts, W = J/s)
- L = thickness of the material along the heat path (meters, m)
- A = cross-sectional area perpendicular to heat flow (square meters, m²)
- ΔT = temperature difference between the two faces (kelvin, K; a °C difference is numerically identical)
- k = thermal conductivity (W/(m·K))
The reciprocal of conductivity is resistivity, and the thermal resistance of a slab is R = L / (k·A), measured in K/W. Higher k means better conductor; lower k means better insulator.
Worked Example
Using the calculator defaults: Q = 100 W, L = 0.05 m, A = 0.25 m², ΔT = 20 K.
- Multiply Q by L: 100 × 0.05 = 5 W·m
- Multiply A by ΔT: 0.25 × 20 = 5 m²·K
- Divide: 5 / 5 = 1.0 W/(m·K)
The calculator returns k = 1.0000 W/(m·K). This is close to water (about 0.6 W/(m·K)) but higher than most plastics (0.1–0.3 W/(m·K)). The thermal resistance R = 0.05 / (1.0 × 0.25) = 0.2 K/W.
Assumptions
- Steady-state heat flow (temperatures constant over time)
- One-dimensional heat transfer (no edge losses)
- Uniform material, homogeneous and isotropic
- Constant thermal conductivity across the temperature range
- Perfect thermal contact at the faces
When to Use This Formula
This formula is the basis for designing heat sinks, insulating building walls, selecting materials for cookware, and estimating heat loss through pipes. It applies to conduction only—not convection or radiation. For a composite wall with multiple layers, you add the thermal resistances of each layer: R_total = R1 + R2 + … and then Q = ΔT / R_total. For cylindrical pipes, the area changes with radius, so the formula uses the logarithmic mean area instead of a simple A.
How to Read the Result
Thermal conductivity values span many orders of magnitude. Pure silver and copper are around 400–430 W/(m·K), aluminum about 205, steel around 50, glass about 1, water 0.6, air 0.026, and foam insulation 0.03–0.04. A higher k means heat moves faster through the material. In practice, engineers often compare materials by k to decide if a material is a conductor or insulator. The calculated k is only valid for the temperature range of the measurement; most materials change k with temperature—metals typically decrease slightly as temperature rises, while insulators increase.
Common Mistakes and Unit Mix-Ups
- Using °C and K interchangeably in ΔT is fine because a difference is the same in both scales, but never use °C for absolute temperature in other formulas.
- Forgetting to convert thickness from cm or mm to meters. A 5 cm slab is 0.05 m, not 5 m.
- Confusing area (m²) with volume (m³). The area is the face the heat passes through, not the side area.
- Using the wrong sign: Q is positive when heat flows from hot to cold; the formula uses the absolute value of ΔT.
- Applying this steady-state formula to transient problems (e.g., heating up a cold oven) where temperature changes with time; that requires the thermal diffusivity and partial differential equations.
Limits of the Formula
This simple formula assumes a flat slab with uniform cross-section. It fails for:
- Curved geometries like pipes or spheres (use logarithmic or mean area)
- Materials with anisotropic conductivity (e.g., wood grain, fiber composites) where k differs by direction
- Very high heat fluxes where radiation or convection becomes significant
- Phase changes (melting, boiling) where latent heat dominates
- Nanoscale materials where phonon mean free path exceeds the thickness
For real engineering, also consider contact resistance between layers—two pressed metal plates do not have the same effective conductivity as a single block because microscopic air gaps resist heat flow.
Related Quantities: Thermal Diffusivity and Resistance
Thermal diffusivity α = k / (ρ·c_p) (m²/s) describes how fast temperature changes propagate through a material, where ρ is density (kg/m³) and c_p is specific heat capacity (J/(kg·K)). Copper has high diffusivity, so it feels cool to the touch quickly; wood has low diffusivity, so it feels warmer. Thermal resistance R = L/(k·A) is used in building codes (R-value, often in imperial units hr·ft²·°F/Btu). To convert R-value (imperial) to SI (K·m²/W), multiply by 0.1761. The calculator above gives R in K/W for the specific geometry entered.
Frequently Asked Questions
What is the difference between thermal conductivity and thermal resistance?
Thermal conductivity (k) is a material property—it does not depend on the size or shape of the object. Thermal resistance (R) depends on the geometry: R = L/(k·A). A thick piece of copper can have higher resistance than a thin piece of steel, even though copper has higher k.
How do I convert W/(m·K) to W/(m·°C)?
You don’t need to. A temperature difference of 1 K is exactly equal to 1 °C, so the numerical value of thermal conductivity is the same in both units. The kelvin is defined so that a change of 1 K equals a change of 1 °C.
Why does the formula use area and thickness?
Because heat flow is proportional to the cross-sectional area (more area, more paths for heat) and inversely proportional to thickness (thicker material, longer path, more resistance). The formula normalizes these geometric effects so that k reflects only the material’s intrinsic behavior.
Can I use this formula for liquids and gases?
Yes, but with caution. For gases, convection usually dominates unless the gas is trapped in small pores (like in foam insulation). For liquids, conduction is real but often overshadowed by convection currents. The formula works for a quiescent fluid layer, but in practice you must ensure no bulk motion.
What is a good thermal conductivity for an insulator?
Typical building insulators have k between 0.02 and 0.05 W/(m·K). Air is 0.026, which is why trapped air in fiberglass or foam provides insulation. Anything below 0.1 W/(m·K) is generally considered a thermal insulator; above 50 W/(m·K) is a conductor.
Does thermal conductivity change with temperature?
Yes, for most materials. Metals typically decrease in k as temperature rises (because electron scattering increases), while ceramics and polymers often increase. The formula assumes a constant k, so for large temperature differences, use the average k over the temperature range or a temperature-dependent function.
Related
Formula used
in q | Heat flow Q | W | 100 | 0 in l | Thickness L | m | 0.05 | 0 in a | Cross-sectional area A | m² | 0.25 | 0.000001 in dt | Temperature difference ΔT | K | 20 | 0.000001 out k | Thermal conductivity | W/(m·K) | q * l / (a * dt) | 4 out r | Thermal resistance R = L/(k·A) | K/W | l / (k * a) | 6
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation with the constants and conversion factors written on the page, rounded as each result states. See method and constants, the disclaimer or report an error.
More in this section
- QPP Calculator Canada: How It Works & How to Use It
- PPP Calculator World Bank: How It Works & How to Use It2,000.00
- PPP Calculator: India vs USA Cost Comparison1,000.00 USD
- PPP Calculator USD to INR: How It Works2,335 INR
- PPP Calculator India vs UK: Real Cost Comparison103.63 GBP
- PPP Calculator India vs Dubai: Real Cost Comparison8,954.58 AED