molecalculator

Moles & Molar Mass

How to Find DNA: Extraction Steps Explained

Guide 01-13663 · Updated · Step by step

This guide explains how to find and extract DNA from common biological samples like cheek cells, fruit, or bacteria. You will learn the basic steps of cell lysis, protein removal, and DNA precipitation, and what equipment and reagents you need. By the end, you will have a visible clump or pellet of DNA that you can spool or resuspend for further study.

What You’ll Need

  • Sample: cheek cells (from a mouth rinse), a strawberry, banana, or a bacterial culture
  • Lysis buffer: 10 mM Tris-HCl (pH 8), 100 mM NaCl, 1 mM EDTA, 0.5% SDS (or a simple dish soap/salt mixture)
  • Proteinase K (optional, for better protein digestion) – final concentration 0.1–1 mg/mL
  • Cold 95–100% ethanol or isopropanol (for precipitation)
  • 3 M sodium acetate (pH 5.2) or 5 M NaCl (to adjust ionic strength)
  • Centrifuge (microcentrifuge or benchtop, capable of 10,000–15,000 × g)
  • Microcentrifuge tubes (1.5 mL) or larger tubes
  • Pipettes and tips
  • Water bath or heat block (37–60 °C)
  • TE buffer or nuclease-free water (for resuspension)
  • Ice bucket

Step-by-Step

  1. Prepare your sample. For cheek cells, rinse your mouth with 10 mL of saline or water and spit into a tube. For a strawberry, remove the green leaves and mash 2–3 berries in a plastic bag with 10 mL of lysis buffer. For bacteria, pellet 1–2 mL of an overnight culture by centrifugation at 5,000 × g for 5 minutes and discard the supernatant.
  2. Lyse the cells. Add 500 µL of lysis buffer to your sample. If using proteinase K, add it to a final concentration of 0.2 mg/mL. Mix gently by inverting the tube. Incubate at 55–60 °C for 10–30 minutes (or at 37 °C for 1 hour if using proteinase K). This breaks open cell membranes and denatures proteins.
  3. Separate insoluble debris. After incubation, centrifuge the tube at 10,000 × g for 5–10 minutes. The cell debris and some proteins will pellet at the bottom. Carefully transfer the supernatant (the liquid above the pellet) to a fresh tube, avoiding the pellet.
  4. Precipitate the DNA. Add 1/10 volume of 3 M sodium acetate (e.g., 50 µL for 500 µL supernatant) and mix. Then add 2 volumes of ice-cold 95–100% ethanol (e.g., 1 mL for 500 µL). Mix by inverting – you should see a white, stringy precipitate forming.
  5. Collect the DNA. Centrifuge at 12,000–15,000 × g for 10 minutes at 4 °C. The DNA will form a small white pellet at the bottom of the tube. Carefully pour off the ethanol without disturbing the pellet.
  6. Wash the pellet (optional but recommended). Add 500 µL of cold 70% ethanol and gently invert the tube. Centrifuge again at 12,000 × g for 5 minutes. Pour off the ethanol and allow the pellet to air-dry for 5–10 minutes. Do not over-dry, as the DNA becomes hard to resuspend.
  7. Resuspend the DNA. Add 30–100 µL of TE buffer or nuclease-free water to the pellet. Gently pipette up and down or tap the tube to dissolve. The DNA is now ready for quantification, PCR, or storage at –20 °C.

Common Mistakes

  • Using too much sample – overloaded tubes can cause incomplete lysis and poor separation.
  • Skipping the proteinase K step – without it, proteins may remain and contaminate the DNA, affecting downstream reactions.
  • Not using cold ethanol – room-temperature ethanol reduces precipitation efficiency.
  • Pouring off the pellet – the DNA pellet is loose; pour slowly and check that it stays attached.
  • Over-drying the pellet – dried DNA is very hard to resuspend; aim for 5–10 minutes.
  • Mixing too vigorously – shears large DNA molecules into fragments.

Tips

  • Use a wide-bore pipette tip or cut the end off a regular tip to reduce shearing when transferring DNA.
  • For fruit, mashing thoroughly increases yield – the more cells broken, the more DNA released.
  • Keep all solutions on ice unless the protocol says otherwise, to slow nuclease activity.
  • If you want to see the DNA without a centrifuge, spool it with a glass rod or pipette tip after adding ethanol – the DNA will wind around the rod.
  • Check the pH of your lysis buffer – a pH around 8 helps keep DNA stable.
  • For high-quality DNA (for PCR), use a commercial kit that includes RNase to remove RNA, but the manual method works for visualization.

Troubleshooting

  • No DNA pellet visible. This often means the DNA concentration is too low. Increase the starting sample amount, ensure the ethanol is cold, and add more salt (sodium acetate) to improve precipitation. Also check that your centrifuge reached the correct speed.
  • DNA pellet is brown or discolored. This indicates contamination with proteins or polyphenols (from fruit). Add more proteinase K, extend incubation time, or use a phenol-chloroform extraction step (with proper safety precautions).
  • DNA does not resuspend. The pellet may be over-dried. Add more buffer and incubate at 55 °C for 10–15 minutes with occasional gentle mixing.
  • DNA appears as a slimy mass that is hard to pipette. This is high-molecular-weight DNA – use a wide-bore tip and pipette slowly.
  • No DNA after ethanol addition. The alcohol may have been added too quickly or the salt concentration was insufficient. Add an additional 1/10 volume of sodium acetate and mix gently, then re-centrifuge.
  • Contamination with RNA. RNA appears as a fuzzy smear on a gel. Treat with RNase A (final concentration 20 µg/mL) at 37 °C for 30 minutes after resuspension.

Frequently Asked Questions

Can I extract DNA without a centrifuge?

Yes, for a simple classroom demonstration, you can use the spooling method: after adding ethanol, the DNA precipitates at the interface and can be wound onto a glass rod. You won’t get a tight pellet, but you will see the DNA.

How much DNA will I get from a strawberry?

A typical strawberry yields around 100–200 µg of DNA per gram of fruit, but this varies with ripeness and extraction efficiency. The visible clump you see is millions of copies of the genome.

Why do I add salt (sodium acetate) before the ethanol?

Salt provides positive ions (Na+) that neutralize the negative phosphate backbone of DNA, making it less soluble in ethanol and allowing it to precipitate out of solution.

Can I use isopropanol instead of ethanol?

Yes, isopropanol works similarly, but it precipitates DNA at a lower concentration (0.6–0.7 volumes) and leaves more salts behind. You may need to wash the pellet more thoroughly with 70% ethanol.

How do I know if the extracted DNA is pure?

Measure the absorbance at 260 nm and 280 nm using a spectrophotometer. A pure DNA sample has an A260/A280 ratio of about 1.8. Lower ratios indicate protein contamination; higher ratios may indicate RNA.

Can I store extracted DNA?

Yes, store DNA in TE buffer at –20 °C. TE buffer contains EDTA, which chelates metal ions that nucleases need, protecting the DNA from degradation. Avoid repeated freeze-thaw cycles.

Related

General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.

More in this section

The whole Moles & Molar Mass section →